Skip to main content
Snapdrive for Unix
本繁體中文版使用機器翻譯,譯文僅供參考,若與英文版本牴觸,應以英文版本為準。

範例AutoSupport

貢獻者

UNIX版提供不同情境的範例。SnapDrive在所有範例中、任何作業系統的資訊內容基本上都相同。AutoSupport

範例:新增儲存系統

下列範例是從名為「x336-207-58」的主機傳送的訊息:

computerName="x336-207-58"
        eventSource="snapdrive"
        appVersion="5.2 for UNIX"
        eventID="3"
        category="sduvs2 configured"
        subject="host_name=x336-207-58, host_os=Linux, host_os_release=2.6.32-279.el6.x86_64, host_os_version=#1 SMP Wed Jun 13 18:24:36 EDT 2012, No of controller=2, PM/RBAC=native, Host Virtualization=No, Multipath-type=nativempio, Protection Enabled=No, Protocol=fcp

範例:重新啟動Daemon

當您重新啟動精靈時、適用於UNIX的功能可將下列資訊傳送至儲存系統:SnapDrive AutoSupport

computerName="x336-207-58"
        eventSource="snapdrive"
        appVersion="5.2 for UNIX"
        eventID="2"
        category="daemon restarted"
        subject="host_name=x336-207-58, host_os=Linux, host_os_release=2.6.32-279.el6.x86_64, host_os_version=#1 SMP Wed Jun 13 18:24:36 EDT 2012, No of controller=2, PM/RBAC=native, Host Virtualization=No, Multipath-type=nativempio, Protection Enabled=No, Protocol=fcp

如果配置了「dFM」、「RBAC方法」設為「dFM」、UNIX版將傳送下列資訊給儲存系統:SnapDrive AutoSupport

computerName="x336-207-58"
        eventSource="snapdrive"
        appVersion="5.2 for UNIX"
        eventID="2"
        category="daemon restarted"
        subject="host_name=x336-207-58, host_os=Linux, host_os_release=2.6.32-279.el6.x86_64, host_os_version=#1 SMP Wed Jun 13 18:24:36 EDT 2012, No of controller=2, PM/RBAC=dfm, Host Virtualization=No, Multipath-type=nativempio, Protection Enabled=Yes, Protocol=fcp"

如果設定「dFM」、並將「RBAC方法」設定為原生、UNIX版的將會傳送下列資訊給儲存系統。SnapDrive AutoSupport

computerName="x336-207-58"
        eventSource="snapdrive"
        appVersion="5.2 for UNIX"
        eventID="2"
        category="daemon restarted"
        subject="host_name=x336-207-58, host_os=Linux, host_os_release=2.6.32-279.el6.x86_64, host_os_version=#1 SMP Wed Jun 13 18:24:36 EDT 2012, No of controller=2, PM/RBAC=native, Host Virtualization=No, Multipath-type=nativempio, Protection Enabled=Yes, Protocol=fcp"

當「建立抓取」作業成功時、適用於UNIX的範圍會傳送下列資訊給儲存系統:SnapDrive AutoSupport

computerName="x336-207-58"
        eventSource="snapdrive"
        appVersion="5.2 for UNIX"
        eventID="5"
        category="snap create successful"
        subject="host_name=x336-207-58, host_os=Linux, host_os_release=2.6.32-279.el6.x86_64, host_os_version=#1 SMP Wed Jun 13 18:24:36 EDT 2012, No of controller=3, PM/RBAC=native, Host Virtualization=No, Multipath-type=nativempio, Protection Enabled=No, Protocol=iscsi, snapshot_name=dg_snap"

當儲存設備顯示所有作業均成功時、適用於UNIX的範圍會傳送下列資訊給儲存系統:SnapDrive AutoSupport

computerName="x336-207-58"
        eventSource="snapdrive"
        appVersion="5.2 for UNIX"
        eventID="3"
        category="general"
        subject="protos=fcp, Connect Luns=8, dgs=4, hvs=3, fs=3, host_name=x336-207-58, host_os=Linux, host_os_release=2.6.32-279.el6.x86_64, host_os_version=#1 SMP Wed Jun 13 18:24:36 EDT 2012, No of controller=2, PM/RBAC=native, Host Virtualization=No, Multipath-type=nativempio, Protection Enabled=No, Protocol=fcp"