hypervisor.phy events

Contributors
Suggest changes

hypervisor.phy.nic.count

Severity

ALERT

Description

This message occurs when the number of physical NICs on the hypervisor is not sufficient for ONTAP® Select support.

Corrective Action

Add NICs to the hypervisor configuration to meet the requirements for ONTAP® Select.

Syslog Message

Insufficient number of physical NICs on the hypervisor: %d. ONTAP® Select requires %d NICs.

Parameters

count (INT): Count of physical NICs active on the hypervisor.
required (INT): Required number of physical NICs for ONTAP® Select to run on the hypervisor.

hypervisor.phy.nic.mtu

Severity

ALERT

Description

This message occurs when the MTU of the physical network interface is not large enough for ONTAP® Select support.

Corrective Action

The MTU for the network interface needs to be configured to the required size in the hypervisor configuration to meet the requirements for ONTAP® Select.

Syslog Message

Physical interface %s on the hypervisor is configured with MTU: %d. ONTAP® Select requires an MTU of %d.

Parameters

name (STRING): Physical network interface name.
mtu (INT): MTU of the physical network interface.
required (INT): Required MTU of the physical network interface.

hypervisor.phy.nic.speed

Severity

ALERT

Description

This message occurs when the speed of the physical network interface is not sufficient for ONTAP® Select support.

Corrective Action

Check the cabling or negotiation for the port speed to meet the requirements for ONTAP® Select.

Syslog Message

Insufficient speed of physical network interface %s on the hypervisor: %s. ONTAP® Select requires %s.

Parameters

name (STRING): Physical network interface name.
speed (STRING): Current speed of the physical network interface in bps.
required (STRING): Required speed of the physical network interface in bps.

hypervisor.phy.nic.status

Severity

ALERT

Description

This message occurs when a physical network interface on the hypervisor is not operational.

Corrective Action

The interface, port, or cabling needs to be investigated for faults. The interface must be up to meet the requirements for ONTAP® Select.

Syslog Message

Physical network interface %s on the hypervisor is not operational. Current status: %s.

Parameters

name (STRING): Physical network interface name.
status (STRING): Opererational status of the physical network interface.