hamsg.dskChkPopulateErr
- Severity
-
ERROR
- Description
-
This message occurs when a disk inventory check cannot be sent to the local node's high-availability (HA) partner because the disk check request could not be correctly constructed.
- Corrective Action
-
Retry the operation. If the problem persists, use the "storage failover show -fields local-missing-disks, partner-missing-disks" command to rescan the disks and to determine the latest ownership. If the disk inventory mismatch is not resolved, check the cabling for either loose connections or for a bad cable on the partner node.
- Syslog Message
-
A disk inventory check cannot be sent to the local node's HA partner. Failure reason: %s.
- Parameters
-
failure_reason (STRING): The reason that the disk inventory check request could not be properly constructed.