hotplug.insert events
Collection of separate PDF docs
Creating your file...
hotplug.insert.badCard.type
- Severity
-
ERROR
- Description
-
This message occurs when the module type does not match the system's record for this slot.
- Corrective Action
-
Use a replacement module of the same type.
- Syslog Message
-
%s module insertion failed in slot %s of node %s because the module type does not match the system's record for this slot.
- Parameters
-
card (STRING): Name of the module.
slot (STRING): Number of the slot.
node (STRING): Name of the node.
hotplug.insert.badCard.ver
- Severity
-
ERROR
- Description
-
This message occurs when the module revision does not match the system's record for this slot.
- Corrective Action
-
Use a replacement module of the same board revision.
- Syslog Message
-
%s module insertion failed in slot %s of node %s because the module revision does not match the system's record for this slot.
- Parameters
-
card (STRING): Name of the module.
slot (STRING): Number of the slot.
node (STRING): Name of the node.
hotplug.insert.illegal_card
- Severity
-
NOTICE
- Description
-
This message occurs when the module inserted is not supported.
- Corrective Action
-
Use vendor-approved modules.
- Syslog Message
-
%s module insertion failed in slot %s of node %s because the module is not supported.
- Parameters
-
card (STRING): Name of the module.
slot (STRING): Number of the slot.
node (STRING): Name of the node.
hotplug.insert.link_not_up
- Severity
-
ALERT
- Description
-
This message occurs when link on module fails to initialize after module is powered on.
- Corrective Action
-
Reinsert the module and try command again. If problem persists, contact NetApp technical support for assistance.
- Syslog Message
-
%s module insertion failed in slot %s of node %s because the link on module failed to initialize.
- Parameters
-
card (STRING): Name of the module.
slot (STRING): Number of the slot.
node (STRING): Name of the node.
hotplug.insert.no_power_up
- Severity
-
ALERT
- Description
-
This message occurs when a module does not initialize after it is powered on.
- Corrective Action
-
Reinsert the module and try the command again. If the problem persists, contact NetApp technical support for assistance.
- Syslog Message
-
%s module insertion failed in slot %s of node %s because module failed to initialize.
- Parameters
-
card (STRING): Name of the module.
slot (STRING): Number of the slot.
node (STRING): Name of the node.
hotplug.insert.success
- Severity
-
NOTICE
- Description
-
This message occurs when module insertion is successful.
- Corrective Action
-
(None).
- Syslog Message
-
%s module insertion is successful in slot %s of node %s.
- Parameters
-
card (STRING): Name of the module.
slot (STRING): Number of the slot.
node (STRING): Name of the node.