nse.op.failed
- Severity
-
ERROR
- Description
-
This message occurs when ONTAP® does not succeed in performing an operation on a NetApp® Storage Encryption (NSE) self-encrypting drive (SED). The message applies to drives that implement either the Trusted Computing Group (TCG) "Enterprise" or "Opal" specification. Some aspect of the operation of NSE drives is compromised.
- Corrective Action
-
If the error persists, replace the drive.
- Syslog Message
-
Control failure on self-encrypting drive %s; security provider: %s, authority: %s, during operation "%s".
- Parameters
-
deviceName (STRING): Name of the device.
securityProvider (STRING): Name of the TCG security provider process.
authority (STRING): Name of the affected TCG authority.
operation (STRING): Description of the operation that failed.