ses.bridge events
Collection of separate PDF docs
Creating your file...
ses.bridge.fw.getFailWarn
- Severity
-
ERROR
- Description
-
This message occurs when the bridge firmware revision cannot be obtained.
- Corrective Action
-
Check the connection to the bank of Maxtor drives.
- Syslog Message
-
On channel %s, the bridge firmware revision could not be obtained using disk IDs %d-%d.
- Parameters
-
ChannelName (STRING): Name of the adapter or switch port that the system tried to get the revision number of.
DiskID (INT): Starting ID of the bank of Maxtor disks that was used to obtain the bridge firmware.
DiskRange (INT): Number of drives in that bank of Maxtor disks.
ses.bridge.fw.mmErr
- Severity
-
ERROR
- Description
-
This message occurs when the bridge firmware revision is inconsistent.
- Corrective Action
-
Check the firmware revision number and make sure that they are consistent. You might have to update the firmware.
- Syslog Message
-
On channel %s, the bridge firmware revision appears to be inconsistent : %8.8s and %8.8s.
- Parameters
-
ChannelName (STRING): Name of the channel that contains the inconsistent firmware revision.
PrevRev (STRING): Previous firmware revision.
CurRev (STRING): Current firmware revision.