no.halt events
Collection of separate PDF docs
Creating your file...
no.halt.brokenDisk
- Severity
-
ALERT
- Description
-
This message occurs when the option raid.timeout is set to 0 or if the option hasn't been set by the user, disabling automatic shutdown on a disk failure.
- Corrective Action
-
Add an appropriate spare disk.
- Syslog Message
-
%s in RAID group "%s" %s broken. Automatic system shutdown has been disabled.
- Parameters
-
type (STRING): Type of disk.
rgname (STRING): RAID group name.
verb (STRING): Failed disk verb.
no.halt.brokenDisk.notice
- Severity
-
NOTICE
- Description
-
This message occurs when a node is in a degraded state because of a broken disk, but the option raid.timeout is set to 0 or its value hasn't been modified by the user, disabling automatic shutdown on a disk failure. Shutdown is to encourage you to replace broken disks. This message occurs on a capacity-optimized platform with broken disks irrespective of the value of the option raid.timeout.
- Corrective Action
-
Consult other logged messages or use the "storage disk show -broken" command to determine the identity of broken disks. Remove any broken disks. Automatic system shutdown can be enabled by altering the "raid.timeout" value using the "storage raid-options modify" command. NOTE: The option "raid.timeout" will not affect the automatic shutdown on a capacity-optimized platform.
- Syslog Message
-
%s. automatic system shutdown is disabled. Replace the disk immediately.
- Parameters
-
type (STRING): Type of degradation.
no.halt.nvramLowBatt.info
- Severity
-
ALERT
- Description
-
This message occurs when the option raid.timeout has been set to 0, disabling automatic shutdown on a low NVRAM Battery condition.
- Corrective Action
-
Replace the NVRAM battery. Automatic system shutdown can be enabled by altering the "raid.timeout" value using the "storage raid-options modify" command.
- Syslog Message
-
Automatic system shutdown is disabled. If the NVRAM battery is dangerously low, replace it immediately.
- Parameters
-
(None).
no.halt.nvramLowBatteries
- Severity
-
ALERT
- Description
-
This message occurs when the option raid.timeout is set to 0, disabling automatic shutdown on a low NVRAM Batteries condition.
- Corrective Action
-
Replace the NVRAM batteries.
- Syslog Message
-
NVRAM batteries are dangerously low. Automatic system shutdown is disabled. Replace the batteries immediately!
- Parameters
-
(None).
no.halt.nvramLowBattery
- Severity
-
ALERT
- Description
-
This message occurs when the option raid.timeout is set to 0, disabling automatic shutdown on a low NVRAM Battery condition.
- Corrective Action
-
Replace the NVRAM battery.
- Syslog Message
-
NVRAM battery is dangerously low. Automatic system shutdown is disabled. Replace the battery immediately!
- Parameters
-
(None).
no.halt.nvramLowBatts.info
- Severity
-
NOTICE
- Description
-
This message occurs when the option raid.timeout has been set to 0, disabling automatic shutdown on a low NVRAM Batteries condition.
- Corrective Action
-
Replace the NVRAM batteries. Automatic system shutdown can be enabled by altering the "raid.timeout" value using the "storage raid-options modify" command.
- Syslog Message
-
Automatic system shutdown is disabled. If the NVRAM batteries are dangerously low, we encourage you to replace it immediately.
- Parameters
-
(None).