no.halt events
no.halt.brokenDisk
- Severity
 - 
ALERT
 - Description
 - 
This message occurs when the option raid.timeout is set to 0 or if the option hasn't been set by the user, disabling automatic shutdown on a disk failure.
 - Corrective Action
 - 
Add an appropriate spare disk.
 - Syslog Message
 - 
%s in RAID group "%s" %s broken. Automatic system shutdown has been disabled.
 - Parameters
 - 
type (STRING): Type of disk.
rgname (STRING): RAID group name.
verb (STRING): Failed disk verb. 
no.halt.brokenDisk.notice
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when a node is in a degraded state because of a broken disk, but the option raid.timeout is set to 0 or its value hasn't been modified by the user, disabling automatic shutdown on a disk failure. Shutdown is to encourage you to replace broken disks. This message occurs on a capacity-optimized platform with broken disks irrespective of the value of the option raid.timeout.
 - Corrective Action
 - 
Consult other logged messages or use the "storage disk show -broken" command to determine the identity of broken disks. Remove any broken disks. Automatic system shutdown can be enabled by altering the "raid.timeout" value using the "storage raid-options modify" command. NOTE: The option "raid.timeout" will not affect the automatic shutdown on a capacity-optimized platform.
 - Syslog Message
 - 
%s. automatic system shutdown is disabled. Replace the disk immediately.
 - Parameters
 - 
type (STRING): Type of degradation.
 
no.halt.nvramLowBatt.info
- Severity
 - 
ALERT
 - Description
 - 
This message occurs when the option raid.timeout has been set to 0, disabling automatic shutdown on a low NVRAM Battery condition.
 - Corrective Action
 - 
Replace the NVRAM battery. Automatic system shutdown can be enabled by altering the "raid.timeout" value using the "storage raid-options modify" command.
 - Syslog Message
 - 
Automatic system shutdown is disabled. If the NVRAM battery is dangerously low, replace it immediately.
 - Parameters
 - 
(None).
 
no.halt.nvramLowBatteries
- Severity
 - 
ALERT
 - Description
 - 
This message occurs when the option raid.timeout is set to 0, disabling automatic shutdown on a low NVRAM Batteries condition.
 - Corrective Action
 - 
Replace the NVRAM batteries.
 - Syslog Message
 - 
NVRAM batteries are dangerously low. Automatic system shutdown is disabled. Replace the batteries immediately!
 - Parameters
 - 
(None).
 
no.halt.nvramLowBattery
- Severity
 - 
ALERT
 - Description
 - 
This message occurs when the option raid.timeout is set to 0, disabling automatic shutdown on a low NVRAM Battery condition.
 - Corrective Action
 - 
Replace the NVRAM battery.
 - Syslog Message
 - 
NVRAM battery is dangerously low. Automatic system shutdown is disabled. Replace the battery immediately!
 - Parameters
 - 
(None).
 
no.halt.nvramLowBatts.info
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when the option raid.timeout has been set to 0, disabling automatic shutdown on a low NVRAM Batteries condition.
 - Corrective Action
 - 
Replace the NVRAM batteries. Automatic system shutdown can be enabled by altering the "raid.timeout" value using the "storage raid-options modify" command.
 - Syslog Message
 - 
Automatic system shutdown is disabled. If the NVRAM batteries are dangerously low, we encourage you to replace it immediately.
 - Parameters
 - 
(None).