A newer release of this product is available.
        
        
      nvmeof.portiomb events
nvmeof.portiomb.clear
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when there are no longer two ports cabled incorrectly from a node to bottom module (B) on a shelf.
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
Two ports are no longer cabled incorrectly from node %s to bottom module (B) on shelf with SN %s.
 - Parameters
 - 
node_name (STRING): Host port connected to the cable.
shelf_sn (STRING): Serial number of the shelf connected to the cable. 
nvmeof.portiomb.error
- Severity
 - 
ERROR
 - Description
 - 
This message occurs when there are two ports cabled to the bottom module (B) on a shelf.
 - Corrective Action
 - 
Connect two ports to different modules to provide redundancy.
 - Syslog Message
 - 
There are two ports cabled from node %s to bottom module (B) on Shelf with SN %s. One of these cables should be removed.
 - Parameters
 - 
node_name (STRING): Host port connected to the cable.
shelf_sn (STRING): Serial number of the shelf connected to the cable.