san.nofcportsonnode events
Collection of separate PDF docs
Creating your file...
san.NoFCPortsOnNode
- Severity
-
ERROR
- Description
-
This message occurs in MetroCluster™ configurations on clustered Data ONTAP® systems when an attempt to place an FCP LIF on a particular node fails because the system cannot find any active ports on that node.
- Corrective Action
-
List the offline FC ports on the DR partner node by using the "fcp adapter show -node <node_name;> -state down" command. Modify the state of the offline FC ports with the following command: "fcp adapter modify -node <node_name;> -adapter <adapter_name;> -state up". Once the FC ports in question are online, resynchronize the Vserver configuration using the "metrocluster vserver resync" command. With the command "fcp adapter show -node <node_name;>" verify that FC ports are present. If the FC ports are absent in the destination cluster node (DR partner), contact customer support to provision the FC ports.
- Syslog Message
-
Cannot find online FC ports on Node "%s" for placing LIF "%s" in Vserver "%s".
- Parameters
-
node_name (STRING): Node name.
lif (STRING): LIF name.
vserver_name (STRING): Vserver name.