Skip to main content
Cloud Insights

HP Enterprise Command View data collector

Contributors netapp-alavoie

The HP Enterprise Command View Advanced Edition data collector supports discovering XP and P9500 arrays via Command View Advanced Edition (CVAE) server. Cloud Insights communicates with CVAE using the standard Command View API to collect inventory and performance data.

Terminology

Cloud Insights acquires the following inventory information from the HP Enterprise Command View data collector. For each asset type acquired by Cloud Insights, the most common terminology used for this asset is shown. When viewing or troubleshooting this data collector, keep the following terminology in mind:

Vendor/Model Term Cloud Insights Term

PDEV

Disk

Journal Pool

Disk Group

Storage Array

Storage

Port Controller

Storage Node

Array Group, DP Pool

Storage Pool

Logical Unit, LDEV

Volume

Note: These are common terminology mappings only and might not represent every case for this data collector.

Inventory requirements

You must have the following in order to collect inventory data:

  • IP address of the CVAE server

  • Read-only user name and password for the CVAE software and peer privileges

  • Port requirement: 2001

Performance requirements

The following requirements must be met in order to collect performance data:

  • HDS USP, USP V, and VSP performance

    • Performance Monitor must be licensed.

    • Monitoring switch must be enabled.

    • The Export Tool (Export.exe) must be copied to the Cloud Insights AU and extracted to a location. On CI Linux AUs, ensure "cisys" has read and execute permissions.

    • The Export Tool version must match the microcode version of the target array.

  • AMS performance:

    • Performance Monitor must be licensed.

    • The Storage Navigator Modular 2 (SNM2) CLI utility be installed on the Cloud Insights AU.

  • Network requirements

    • The Export Tools are Java based, and use RMI to speak to the array. These tools may not be firewall-friendly as they may dynamically negotiate source and destination TCP ports on each invocation. Also, different model array's Export Tools may behave differently across the network - consult HPE for your model's requirements

Configuration

Field Description

Command View Server

IP address or fully-qualified domain name of the Command View server

User Name

User name for the Command View server.

Password

Password used for the Command View server.

Devices - VSP G1000 (R800), VSP (R700), HUS VM (HM700) and USP storages

Device list for VSP G1000 (R800), VSP (R700), HUS VM (HM700) and USP storages. Each storage requires:

* Array's IP: IP address of the storage
* User Name: User name for the storage
* Password: Password for the storage
* Folder Containing Export Utility JAR Files

SNM2Devices - WMS/SMS/AMS Storages

Device list for WMS/SMS/AMS storages. Each storage requires:

* Array's IP: IP address of the storage
* Storage Navigator CLI Path: SNM2 CLI path
* Account Authentication Valid: Select to choose valid account authentication
* User Name: User name for the storage
* Password: Password for the storage

Choose Tuning Manager for Performance

Override other performance options

Tuning Manager Host

IP address or fully-qualified domain name of tuning manager

Tuning Manager Port

Port used for Tuning Manager

Tuning Manager Username

User name for Tuning Manager

Tuning Manager Password

Password for Tuning Manager

Note: In HDS USP, USP V, and VSP, any disk can belong to more than one array group.

Advanced configuration

Field

Description

Command View Server Port

Port used for the Command View Server

HTTPs Enabled

Select to enable HTTPs

Inventory Poll Interval (min)

Interval between inventory polls. The default is 40.

Choose 'Exclude' or 'Include' to specify a list

Specify whether to include or exclude the array list below when collecting data.

Exclude or Include Devices

Comma-separated list of device ID's or array names to include or exclude

Query Host Manager

Select to query host manager

Performance Polling Interval (sec)

Interval between performance polls. The default is 300.

Troubleshooting

Some things to try if you encounter problems with this data collector:

Inventory

Problem: Try this:

Error: User does not have enough permission

Use a different user account that has more privilege or increase the privilege of user account configured in the data collector

Error: Storages list is empty. Either devices are not configured or the user does not have enough permission

* Use DeviceManager to check if the devices are configured.
* Use a different user account that has more privilege, or increase the privilege of the user account

Error: HDS storage array was not refreshed for some days

Investigate why this array is not being refreshed in HP CommandView AE.

Performance

Problem: Try this:

Error:
* Error executing export utility
* Error executing external command

* Confirm that Export Utility is installed on the Cloud Insights Acquisition Unit
* Confirm that Export Utility location is correct in the data collector configuration
* Confirm that the IP of the USP/R600 array is correct in the configuration of the data collector
* Confirm that the User name and password are correct in the configuration of the data collector
* Confirm that Export Utility version is compatible with storage array micro code version
* From the Cloud Insights Acquisition Unit, open a CMD prompt and do the following:
- Change the directory to the configured installation directory
- Try to make a connection with the configured storage array by executing batch file runWin.bat

Error: Export tool login failed for target IP

* Confirm that username/password is correct
* Create a user ID mainly for this HDS data collector
* Confirm that no other data collectors are configured to acquire this array

Error: Export tools logged "Unable to get time range for monitoring".

* Confirm performance monitoring is enabled on the array.
* Try invoking the export tools outside of Cloud Insights to confirm the problem lies outside of Cloud Insights.

Error:
* Configuration error: Storage Array not supported by Export Utility
* Configuration error: Storage Array not supported by Storage Navigator Modular CLI

* Configure only supported storage arrays.
* Use “Filter Device List” to exclude unsupported storage arrays.

Error:
* Error executing external command
* Configuration error: Storage Array not reported by Inventory
* Configuration error:export folder does not contains jar files

* Check Export utility location.
* Check if Storage Array in question is configured in Command View server
* Set Performance poll interval as multiple of 60 seconds.

Error:
* Error Storage navigator CLI
* Error executing auperform command
* Error executing external command

* Confirm that Storage Navigator Modular CLI is installed on the Cloud Insights Acquisition Unit
* Confirm that Storage Navigator Modular CLI location is correct in the data collector configuration
* Confirm that the IP of the WMS/SMS/SMS array is correct in the configuration of the data collector
* Confirm that Storage Navigator Modular CLI version is compatible with micro code version of storage array configured in the data collector
* From the Cloud Insights Acquisition Unit, open a CMD prompt and do the following:
- Change the directory to the configured installation directory
- Try to make a connection with the configured storage array by executing following command “auunitref.exe”

Error: Configuration error: Storage Array not reported by Inventory

Check if Storage Array in question is configured in Command View server

Error:
* No Array is registered with the Storage Navigator Modular 2 CLI
* Array is not registered with the Storage Navigator Modular 2 CLI
* Configuration error: Storage Array not registered with StorageNavigator Modular CLI

* Open Command prompt and change directory to the configured path
* Run the command “set=STONAVM_HOME=.”
* Run the command “auunitref”
* Confirm that the command output contains details of the array with IP
* If the output does not contain the array details then register the array with Storage Navigator CLI:
- Open Command prompt and change directory to the configured path
- Run the command “set=STONAVM_HOME=.”
- Run command “auunitaddauto -ip ${ip}”. Replace ${ip} with real IP

Additional information may be found from the Support page or in the Data Collector Support Matrix.