Skip to main content
Data Infrastructure Insights

Configuring the EMC Unity data collector

Contributors netapp-alavoie

The DELL EMC Unity (formerly VNXe) data collector provides inventory support for VNXe unified storage arrays. Data Infrastructure Insights currently supports iSCSI and NAS protocols.

Requirements

  • The Unity data collector is CLI based; you must install the Unisphere for Unity CLI, (uemcli.exe) onto the acquisition unit where your VNXe data collector resides.

  • uemcli.exe uses HTTPS as the transport protocol, so the acquisition unit will need to be able to initiate HTTPS connections to the Unity.

  • IP address or fully-qualified domain name of the Unity device

  • You must have at least a read-only user for use by the data collector.

  • HTTPS on Port 443 is required

  • The EMC Unity data collector provides NAS and iSCSI support for inventory; fibre channel volumes will be discovered, but Data Infrastructure Insights does not report on FC mapping, masking, or storage ports.

Terminology

Data Infrastructure Insights acquires the following inventory information from the Unity data collector. For each asset type acquired by Data Infrastructure Insights, the most common terminology used for this asset is shown. When viewing or troubleshooting this data collector, keep the following terminology in mind:

Vendor/Model Term Data Infrastructure Insights Term

Disk

Disk

Storage Array

Storage

Processor

Storage Node

Storage Pool

Storage Pool

General iSCSI Block info, VMware VMFS

Share

Replication Remote System

Synchronization

iSCSI Node

iSCSI Target Node

iSCSI Initiator

iSCSI Target Initiator

Note: These are common terminology mappings only and might not represent every case for this data source.

Configuration

Field Description

Unity Storage

IP address or fully-qualified domain name of the Unity device

User Name

User name for the Unity device

Password

Password for the Unity device

Full Path to the Executable UEMCLI

Full path to the folder containing the uemcli.exe executable

Advanced configuration

Field Description

Inventory Poll Interval (min)

Interval between inventory polls. The default is 40 minutes

Unity CLI Port

Port used for the Unity CLI

Performance poll interval (sec)

The default is 300.

Troubleshooting

Some things to try if you encounter problems with this data collector:

Inventory

Problem: Try this:

"Failed to execute external utility" with error messages “Failed to find Unisphere executable uemcli”

* Verify correct IP address, username, and password
* Confirm that Unisphere CLI is installed on the Data Infrastructure Insights Acquisition Unit
* Confirm that Unisphere CLI installation directory is correct in the datasource configuration
* Confirm that the IP of the VNXe is correct in the configuration of the datasource. From the Data Infrastructure Insights Acquisition Unit, open a CMD and change to to the configured installation directory: ${INSTALLDIR. Try to make a connection with the VNXe device by typing: uemcli -d <Your IP> -u <Your ID> /sys/general show

Additional information may be found from the Support page or in the Data Collector Support Matrix.