Skip to main content
Data Infrastructure Insights

IBM System Storage DS8000 Series data collector

Contributors netapp-alavoie

The IBM DS (CLI) data collector supports inventory and performance data acquisition for DS6xxx and DS8xxx devices.

DS3xxx, DS4xxx, and DS5xxx devices are supported by the NetApp E-Series data collector. You should refer to the Data Infrastructure Insights support matrix for supported models and firmware versions.

Terminology

Data Infrastructure Insights acquires the following inventory information from the IBM DS data collector. For each asset type acquired by Data Infrastructure Insights, the most common terminology used for this asset is shown. When viewing or troubleshooting this data collector, keep the following terminology in mind:

Vendor/Model Term Data Infrastructure Insights Term

Disk Drive Module

Disk

Storage Image

Storage

Extent Pool

Storage Node

Fixed Block Volume

Volume

Host FC Initiator (Mapped)

Volume Mask

Note: These are common terminology mappings only and might not represent every case for this data collecor.

Requirements

You need the following to configure this data collector:

  • IP address of each DS array

  • Read-only username and password on each DS array

  • Third-party software installed on the Data Infrastructure Insights AU: IBM dscli

  • Access validation: Run dscli commands using the username and password

  • Port requirements: 80, 443, & 1750

Configuration

Field Description

DS Storage

IP address or fully-qualified domain name of the DS device

User Name

User name for the DS CLI

Password

Password for the DS CLI

dscli executable path

Full path to the dscli executable

Advanced configuration

Field Description

Inventory Poll Interval (min)

Interval between inventory polls (min). The default is 40.

Storage Display Name

Name of the IBM DS storage array

Inventory Exclude Devices

Comma-separated list of device serial numbers to exclude from inventory collection

Performance Poll Interval (sec)

The default is 300.

Performance Filter Type

Include: Data collected only from devices on list. Exclude: No data from these devices is collected

Performance Filter Device List

Comma-separated list of device IDs to include or exclude from performance collection

Troubleshooting

Some things to try if you encounter problems with this data collector:

Inventory

Problem: Try this:

Error containing: CMUC00192E, CMUC00191E or CMUC00190E

* Verify credentials and IP address entered.
* Try to communicate with the array through web management console https://<ip>:8452/DS8000/Console. Replace <ip> with data collector configured IP.

Error:
* Cannot run program
* Error executing command

* From Data Infrastructure Insights Acquisition Unit Open a CMD
* Open CLI.CFG file in CLI's home dir/lib and check property JAVA_INSTALL, edit the value to match your environment
* Display Java version installed on this machine, typing: "java -version"
* Ping the IP address of the IBM Storage device specified in CLI command issued.
* If all the above worked fine then manually run a CLI command

Additional information may be found from the Support page or in the Data Collector Support Matrix.