Configuring the NetApp HCI Management server data collector
The NetApp HCI Management server data collector collects NetApp HCI Host information and requires read-only privileges on all objects within the Management server.
This data collector acquires from the NetApp HCI Management server only. To collect data from the storage system, you must also configure the NetApp SolidFire data collector.
Terminology
Data Infrastructure Insights acquires the following inventory information from this data collector. For each asset type acquired, the most common terminology used for the asset is shown. When viewing or troubleshooting this data collector, keep the following terminology in mind:
Vendor/Model Term | Data Infrastructure Insights Term |
---|---|
Virtual disk |
Disk |
Host |
Host |
Virtual machine |
Virtual machine |
Data store |
Data store |
LUN |
Volume |
Fibre channel port |
Port |
These are common terminology mappings only and might not represent every case for this data collector.
Requirements
The following information is required to configure this data collector:
-
IP address of the NetApp HCI Management server
-
Read-only username and password for the NetApp HCI Management server
-
Read only privileges on all objects in the NetApp HCI Management server.
-
SDK access on the NetApp HCI Management server – normally already set up.
-
Port requirements: http-80 https-443
-
Validate access:
-
Log into the NetApp HCI Management server using above username and password
-
Verify SDK enabled: telnet <vc_ip> 443
-
Setup and connection
Field | Description |
---|---|
Name |
Unique name for the data collector |
Acquisition unit |
Name of acquisition unit |
Configuration
Field | Description |
---|---|
NetApp HCI Storage Cluster MVIP |
Management Virtual IP Address |
SolidFire Management Node (mNode) |
Management Node IP Address |
User name |
User name used to access the NetApp HCI Management server |
Password |
Password used to access the NetApp HCI Management server |
VCenter User Name |
User name for VCenter |
VCenter Password |
Password for VCenter |
Advanced configuration
In the advanced configuration screen, check the VM Performance box to collect performance data. Inventory collection is enabled by default.
The following fields can be configured:
Field |
Description |
Inventory poll interval (min) |
Deafult is 20 |
Filter VMs by |
Select CLUSTER, DATACENTER, or ESX HOST |
Choose 'Exclude' or 'Include' to Specify a List |
Specify Whether to Include or Exclude VMs |
Filter Device List |
List of VMs to filter (comma separated, or semicolon separated if comma is used in the value) for for Filtering by ESX_HOST, CLUSTER, and DATACENTER Only |
Performance poll interval (sec) |
Default is 300 |
Troubleshooting
Some things to try if you encounter problems with this data collector:
Inventory
Problem: | Try this: |
---|---|
Error: Include list to filter VMs cannot be empty |
If Include List is selected, please list valid DataCenter, Cluster, or Host names to filter VMs |
Error: Failed to instantiate a connection to VirtualCenter at IP |
Possible solutions: |
Error: VirtualCenter at IP has non-conform certificate that JVM requires |
Possible solutions: |
Additional information may be found from the Support page or in the Data Collector Support Matrix.