Skip to main content
Data Infrastructure Insights

Nutanix AHV data collector

Contributors netapp-alavoie

The Nutanix AHV collector acquires Nutanix Acropolis Hypervisor (AHV) inventory and virtualization performance from Nutanix Prism Central using Prism Central v4 REST APIs (Cluster Management and Virtual Machine Management namespaces). It reports data in the virtualization OData model (VirtualizationRoot and related entities: hosts, virtual machines, datastores, virtual disks, and relationships).

Terminology

Vendor/Model Term Data Infrastructure Insights Term

AHV Node (Host)

Host

Prism Central Cluster

Hypervisor (Virtual Server)

Acropolis VM

Virtual Machine

Storage Container

Data Store

ADSF Volume Group

LUN

VM Disk

Virtual Disk

Note: These are common terminology mappings only and might not represent every case for this data collector.

Requirements

  • Prism Central IP address or Fully Qualified Domain Name

  • Prism Central local or LDAP username and password (read-only account is sufficient for inventory and performance; Admin is not required)

  • Port requirement: HTTPS 9440

  • Prism Central version pc.2023.x or later (v3 API); pc.7.x or later recommended (v4 API)

  • Performance metrics require Prism Central with API v4.0.b1 or later (pc.7.3+). On older versions, inventory is still collected but no performance data is reported.

Configuration

Field Description

Prism Central IP Address

IP address or FQDN of the Prism Central instance

User name

Prism Central username

Password

Prism Central password

Advanced configuration

Field Description

TCP port

TCP Port used to connect to Prism Central. The default is 9440.

Inventory poll interval (min)

Interval between inventory polls. The default is 60 minutes.

Performance poll interval(sec)

Interval between performance polls. The default is 300 seconds.

HTTP timeout (sec)

HTTP request timeout. The default is 60 seconds.

HTTP retry count

Number of HTTP retries on transient failures. Default is 3.

Troubleshooting