Skip to main content
SANtricity commands

Reset storage array iSER baseline

Contributors netapp-driley

The reset storageArray iserStatsBaseline command resets the iSER baseline to 0 for the storage array.

Supported Arrays

This command applies to any individual storage array, including the E2700, E5600, E2800 and E5700 arrays, as long as all SMcli packages are installed.

Roles

To execute this command on an E2800, or E5700 storage array, you must have the Storage Admin role.

Note

This command is deprecated and is replaced by the Reset storage array host port statistics baseline command.

Syntax

reset storageArray iserStatsBaseline

Parameters

None.

Notes

This command does not actually reset the raw counts maintained in the hardware and firmware. Instead, the firmware creates a snapshot of the current counter values and uses these values to report differences in the counts when the statistics are retrieved. The new baseline time is applied to both controllers so that the controller counts are synchronized with each other. If one controller resets without the other controller resetting, the counters are no longer synchronized. The client becomes aware that the controllers are not synchronized because the timestamp data reported along with the statistics is not the same for both controllers.

Minimum firmware level

8.20

8.41 This command is deprecated.