Skip to main content
SANtricity commands

Set storage array

Contributors netapp-driley

The set storageArray command defines the properties of the storage array.

Supported Arrays

This command applies to any individual storage array, including the E4000, E2700, E5600, E2800, E5700, EF600 and EF300 arrays, as long as all SMcli packages are installed.

Roles

To execute this command on an E4000, E2800, E5700, EF600, or EF300 storage array, you must have the Storage Admin role.

Context

Note

With firmware version 8.10 the cacheFlushStop parameter is deprecated and will be removed in a future release of storage management software.

Syntax

set storageArray
([autoLoadBalancingEnable=(TRUE | FALSE)]|
[autoSupportMaintenanceWindow AutoSupport Maintenance Window parameters]
[autoSupport schedule AutoSupport Schedule Parameters]|
[autoSupportConfig (enable | disable)]|
[autoSupportOnDemand (enable | disable)]|
[autoSupportRemoteDiag (enable |disable)]|
[cacheBlockSize=cacheBlockSizeValue]|
[cacheFlushStart=cacheFlushStartSize]|
[cacheMirrorDataAssuranceCheckEnable=(TRUE | FALSE)]|
[controllerHealthImageAllowOverWrite]|
[defaultHostType=("hostTypeName" |"hostTypeIdentifier")] |
[directoryServer directory server parameters]|
[externalKeyManagement external key management parameters]|
[failoverAlertDelay=delayValue]|
[hostConnectivityReporting (enable | disable)]|
[icmpPingResponse=(TRUE | FALSE)]|
[isnsIPV4ConfigurationMethod isns IPv4 Config Method Parameters]|
[isnsIPv6Address=ipAddress]|
[isnsListeningPort=listeningPortIPAddress]|
[isnsRegistration=(TRUE | FALSE)]|
[learnCycleDate learn cycle parameters]|
[localUsername=local user name parameters]|
[loginBanner file="path_to_login_banner"]|
[managementInterface restOnly={true | false}]|
[mediaScanRate=(disabled | 1-210)]|
[odxEnabled=(TRUE | FALSE)]|
[password="password"]|
[passwordLength=<INTEGER>]|
[pqValidateOnReconstruct P/Q Validate on Reconstruct parameters]|
[redundancyMode=(simplex | duplex)]|
[revocationCheckSettings revocation check settings parameters]|
[securityKey]|
[symbol SYMbol user name and password parameters]|
[syslog syslog parameters]|
[time]|
[trayPositions=(controller | trayID ... trayIDn)]|
[unnamedDiscoverySession=(TRUE | FALSE)]|
[userLabel="storageArrayName"]|
[userSession sessionTimeout=n]|
[vaaiEnabled=(TRUE | FALSE)])

Parameters

Parameter Description

autoLoadBalancingEnable

This parameter enables auto-load balancing on the controller. To enable the option, set this parameter to TRUE. To disable the option, set this parameter to FALSE.

Note

When the Automatic Load Balancing feature is enabled, the Host Connectivity Reporting feature will also be enabled.

autoSupport schedule

Sets the daily and weekly times and days of the week that AutoSupport messages are sent.

autoSupportConfig

The setting for automatically collecting support data each time the firmware detects a critical MEL event. This parameter has these values:

  • enable — Turns on the collection of support data

  • disable — Turns off the collection of support data

Use this parameter under these conditions only:

  • The AutoSupport (ASUP) feature is not available on the storage array

  • To support configurations on storage arrays that previously used this parameter

Note

You cannot use this parameter with the ASUP commands.

autoSupportMaintenanceWindow

Turns on or turns off the AutoSupport maintenance window feature and configures the feature.

cacheBlockSize

The cache block size that is used by the controller for managing the cache. Valid values are 4 (4 KB), 8 (8 KB), 16 (16 KB), or 32 (32 KB).

cacheMirrorDataAssuranceCheckEnable

This parameter enables cache mirror data assurance check on the controller. To enable the option, set this parameter to TRUE. To disable the option, set this parameter to FALSE.

cacheFlushStart

The percentage of unwritten data in the cache that causes a cache flush. Use integer values from 0 to 100 to define the percentage. The default value is 80.

cacheFlushStop

Note

This parameter is deprecated and will be removed in a future release.

The percentage of unwritten data in the cache that stops a cache flush. Use integer values from 0 to 100 to define the percentage. This value must be less than the value of the cacheFlushStart parameter.

controllerHealthImageAllowOverWrite

Sets a flag on a controller to allow a new controller health image to overwrite an existing controller health image on storage arrays that support the controller health image feature.

defaultHostType

The default host type of any unconfigured host port to which the controllers are connected. To generate a list of valid host types for the storage array, run the show storageArray hostTypeTable command. Host types are identified by a name or a numerical index. Enclose the host type name in double quotation marks (" "). Do not enclose the host type numerical identifier in double quotation marks.

directoryServer

Updates the directory server configuration, including role mappings.

externalKeyManagement

Configures the external key management server address and port number

failoverAlertDelay

The failover alert delay time in minutes. The valid values for the delay time are 0 to 60 minutes. The default value is 5.

hostConnectivityReporting

This parameter enables host connectivity reporting on the controller. To enable the option, set this parameter to enable. To disable the option, set this parameter to disable.

Note

If you attempt to disable Host Connectivity Reporting when Automatic Load Balancing is enabled, you receive an error. First disable the Automatic Load Balancing feature, then disable the Host Connectivity Reporting feature.

Note

You can keep Host Connectivity Reporting enabled when Automatic Load Balancing is disabled.

icmpPingResponse

This parameter turns on or turns off Echo Request messages. Set the parameter to TRUE to turn on Echo Request messages. Set the parameter to FALSE to turn off Echo Request messages.

isnsIPv4ConfigurationMethod

The method that you want to use to define the iSNS server configuration. You can enter the IP address for the IPv4 iSNS servers by selecting static. For IPv4, you can choose to have a Dynamic Host Configuration Protocol (DHCP) server select the iSNS server IP address by entering dhcp. To enable DHCP, you must set the isnsIPv4Address parameter to 0.0.0.0.

isnsIPv6Address

The IPv6 address that you want to use for the iSNS server.

isnsListeningPort

The IP address that you want to use for the iSNS server listening port. The range of values for the listening port is 49152 to 65535. The default value is 53205.

The listening port resides on the server and performs these activities:

  • Monitors incoming client connection requests

  • Manages traffic to the server

When a client requests a network session with a server, the listener receives the actual request. If the client information matches the listener information, then the listener grants a connection to the database server.

isnsRegistration

This parameter lists the storage array as an iSCSI target on the iSNS server. To register the storage array on the iSNS server, set this parameter to TRUE. To remove the storage array from the iSNS server, set this parameter to FALSE.

Note

You cannot use the isnsRegistration parameter with any other parameter when running the set storageArray command.

For more information about iSNS registration, refer to the set storageArray isnsRegistration command.

learnCycleDate

Sets controller battery learn cycles.

localUsername

Allows you to set a local user name password or a SYMbol password for a particular role.

loginBanner

Allows you to upload a text file to be used as a login banner. The banner text can include an advisory notice and consent message, which is presented to users before they establish sessions in SANtricity System Manager or before they run commands

managementInterface

Changes the management interface of the controller. Change the management interface type to enforce confidentiality between the storage array and its management software or to access external tools.

mediaScanRate

The number of days over which the media scan runs. Valid values are disabled , which turns off the media scan, or 1 day to 210 days, where 1 day is the fastest scan rate, and 210 days is the slowest scan rate. A value other than disabled or 1 through 210 does not allow the media scan to function.

odxEnabled

Turns on or turns off Offloaded Data Transfer (ODX) for a storage array.

password

The password for the storage array. Enclose the password in double quotation marks (" ").

Note

With the 8.40 release, this parameter is deprecated. Use the localUsername or the symbol symbol parameters, along with the password or adminPassword parameters, instead.

passwordLength

Allows you to set the minimum required length for all new or updated passwords. Use a value between 0 and 30.

pqValidateOnReconstruct

Modifies the P/Q validate on reconstruction capability.

redundancyMode

Use simplex mode when you have a single controller. Use duplex mode when you have two controllers.

revocationCheckSettings

Allows you to enable or disable revocation checking, and configure an Online Certificate Status Protocol (OCSP) server.

securityKey

Sets the internal security key that is used throughout the storage array to implement the Drive Security feature.

Note

Used for an internal security key. When an external key management server is used, use the create storageArray securityKey command.

symbol

Allows you to set a SYMbol password for a particular role.

syslog

Allows you to change the syslog server address, protocol, or port number.

time

Sets the clocks on both controllers in a storage array by synchronizing the controller clocks with the clock of the host from which you run this command.

trayPositions

A list of all of the tray IDs. The sequence of the tray IDs in the list defines the positions for the controller tray and the drive trays in a storage array. Valid values are 0 to 99. Enter the tray ID values separated with a space. Enclose the list of tray ID values in parentheses. For storage arrays where the controller tray has a predefined identifier that is not in the range of valid tray position values, use the controller value.

Note

The controller option is not valid after firmware release 6.14.

unnamedDiscoverySession

Enables the storage array to participate in unnamed discovery sessions.

userLabel

The name for the storage array. Enclose the storage array name in double quotation marks (" ").

userSession

Allows you to set a timeout in System Manager, so that users' inactive sessions are disconnected after a specified time.

vaaiEnabled

Turns on or turns off VMware vStorage API Array Architecture (VAAI) for a storage array

Notes

Except for the isnsRegistration, when you use this command you can specify one or more of the optional parameters.

Auto Support data

Note

You cannot use this parameter with the ASUP commands.

When enabled, the set storageArray autoSupportConfig command causes all configuration and state information for the storage array to be returned each time a critical Major Event Log (MEL) event is detected. The configuration and state information is returned in the form of an object graph. The object graph contains all relevant logical and physical objects and their associated state information for the storage array.

The set storageArray autoSupportConfig command collects configuration and state information in this way:

  • Automatic collection of the configuration and state information occurs every 72 hours. The configuration and state information is saved to the storage array zip archive file. The archive file has a time stamp that is used to manage the archive files.

  • Two storage array zip archive files are maintained for each storage array. The zip archive files are kept on a drive. After the 72-hour time period is exceeded, the oldest archive file is always overwritten during the new cycle.

  • After you enable automatic collection of the configuration and state information using this command, an initial collection of information starts. Collecting information after the you issue the command makes sure that one archive file is available and starts the time stamp cycle.

You can run the set storageArray autoSupportConfig command on more than one storage array.

Cache block size

When you define cache block sizes, use the 4-KB cache block size for storage arrays that require I/O streams that are typically small and random. Use the 8-KB cache block size when the majority of your I/O streams are larger than 4 KB but smaller than 8 KB. Use the 16-KB cache block size or the 32-KB cache block size for storage arrays that require large data transfer, sequential, or high-bandwidth applications.

The cacheBlockSize parameter defines the supported cache block size for all of the volumes in the storage array. Not all controller types support all cache block sizes. For redundant configurations, this parameter includes all of the volumes that are owned by both controllers within the storage array.

Cache flush start

When you define values to start a cache flush, a value that is too low increases the chance that data needed for a host read is not in the cache. A low value also increases the number of drive writes that are necessary to maintain the cache level, which increases system overhead and decreases performance.

Default host type

When you define host types, if Storage Partitioning is enabled, the default host type affects only those volumes that are mapped in the default group. If Storage Partitioning is not enabled, all of the hosts that are attached to the storage array must run the same operating system and be compatible with the default host type.

Media scan rate

Media scan runs on all of the volumes in the storage array that have Optimal status, do not have modification operations in progress, and have the mediaScanRate parameter enabled. Use the set volume command to enable or disable the mediaScanRate parameter.

Password

Passwords are stored on each storage array. For best protection, the password must meet these criteria:

  • The password must be between eight and 30 characters long.

  • The password must contain at least one uppercase letter.

  • The password must contain at least one lowercase letter.

  • The password must contain at least one number.

  • The password must contain at least one non-alphanumeric character, for example, < > @ +.

Note

If you are using full disk encryption drives in your storage array, you must use these criteria for your storage array password.

Note

You must set a password for your storage array before you can create a security key for encrypted full disk encryption drives.

Minimum firmware level

5.00 adds the defaultHostType parameter.

5.40 adds the failoverAlertDelay parameter.

6.10 adds the redundancyMode, trayPositions, and time parameters.

6.14 adds the alarm parameter.

7.10 adds the icmpPingResponse, unnamedDiscoverySession, isnsIPv6Address, and isnsIPv4ConfigurationMethod parameters.

7.15 adds more cache block sizes and the learnCycleDate parameter.

7.86 removes the alarm parameter because it is no longer used, and adds the coreDumpAllowOverWrite parameter.

8.10 deprecates the cacheFlushStop parameter.

8.20 adds the odxEnabled and vaaiEnabled parameters.

8.20 updates the cacheBlockSize parameter to add the cacheBlockSizeValue of 4 (4 KB).

8.20 replaces the coreDumpAllowOverWrite parameter with the controllerHealthImageAllowOverWrite parameter.

8.30 adds the autoLoadBalancingEnable parameter.

8.40 adds the localUsername parameter (used with a user name variable and either the password or adminPassword parameter. Also adds the symbol parameter (used with a user name variable and either the password or adminPassword parameter.

8.40 deprecates the password and userRole standalone parameters.

8.40 adds the managementInterface parameter.

8.40 adds the externalKeyManagement parameter.

8.41 adds the cacheMirrorDataAssuranceCheckEnable, directoryServer, userSession, passwordLength, and loginBanner parameters.

8.42 adds the pqValidateOnReconstruct, syslog, hostConnectivityReporting, and revocationCheckSettings parameters.