Display AutoSupport bundle collection settings
The SMcli -autoSupportConfig show
command displays the AutoSupport bundle collection settings for the management domain. These settings apply to all of the storage arrays in your management domain for which you have enabled AutoSupport.
Supported Arrays
This command applies to all E2700 and E5600 storage arrays in the management domain at once. It does not apply to E2800 or E5700 storage arrays.
Context
The command output from this command shows the following configuration information:
-
The activation status for this management domain of the AutoSupport feature, the AutoSupport OnDemand feature, and the AutoSupport Remote Diagnostics feature
-
Delivery parameters that depend on the configured delivery method:
-
Delivery method is SMTP: Destination email address, mail relay server, and sender email address are shown
-
Delivery method is HTTP or HTTPs:
-
Direct connection - destination IP address is shown
-
Proxy server connection - Host address, port number, and authentication details are shown
-
Automatic proxy configuration script (PAC) connection - script location is shown
-
-
-
A table that lists, for each storage array, the name of the array, whether or not it is an ASUP-capable array, the chassis serial numbers, and the IP addresses for the controllers in the array
Context
This command is an SMcli command, not a script command. You must run this command from a command line. You cannot run this command from the script editor in the storage management software. |
This command applies to all E2700 and E5600 storage arrays in the management domain at once. It does not apply to E2800 or E5700 storage arrays. |
Syntax
SMcli -autoSupportConfig show
Parameters
None.
Minimum Firmware Level
8.25
Example output for the activation statuses
The AutoSupport feature is activated on this storage management station. The AutoSupport OnDemand feature is de-activated on this storage management station. The AutoSupport Remote Diagnostics feature is de-activated on this storage management station.
Example output for the SMTP delivery method
Delivery method: SMTP Destination email address: http://asupserver.corp.netapp.com/put/AsupPut/ Mail relay server: server.eng.netapp.com Sender email address: user@netapp.com
Example output for the HTTP or HTTPS delivery method with a direct connection
Delivery method: HTTP Destination IP address: http://asupserver.corp.netapp.com/put/AsupPut/ Connection: Direct
Example output for the HTTP delivery method with a proxy connection
Connection: Proxy server Host Address: 10.227.76.123 Port number: 8080 Authentication required: Yes User name: admin Password: **********
Example output for the HTTP delivery method with an automatic proxy configuration script (PAC)
Connection: Automatic proxy configuration script (PAC) Script location: http://esgweb.eng.netapp.com/~user/proxy.pac
Example output for array table (all delivery methods)
Name AutoSupport Capable Chassis Serial Number IP Address SA_1 Yes (enabled) SX94500434 10.113.173.123, 10.113.173.456 SA_2 Yes (disabled) SX94607107 10.113.174.789, 10.113.174.345 SA_3 No Not available 10.113.59.58, 10.113.59.59