Connect the power cables - E4060
Learn how to attach the power cables and power on the drive shelves.
-
Install your hardware.
-
Take anti-static precautions.
This procedure applies to IOM12, IOM12B, and IOM12C drive shelves.
-
Cable the shelves.
Cable the system according to your configuration.
If you need more cabling options than the examples provided below, see Cabling. You need the following cables:
SAS cables
-
Example A: An E4060 controller shelf with two DE460C disk shelves in a standard SAS configuration
-
Cable controller A to IOM A of the first drive shelf.
-
Cable IOM A of the first drive shelf to IOM A of the second drive shelf.
-
Cable IOM B of the first drive shelf to IOM B of the second drive shelf.
-
Cable controller B to IOM B of the second drive shelf.
-
-
Example B: An E4060 controller shelf with one DE460C disk shelf in a standard SAS configuration
-
Cable controller A to IOM A.
-
Cable controller B to IOM B.
-
-
-
Power the drive shelves.
You need the following cables:
Power cables
Confirm the drive shelf power switches are off. -
Connect the two power cables for each shelf to different power distribution units (PDUs) in the cabinet or rack.
-
If you have drive shelves, turn on their two power switches first. Wait 2 minutes before applying power to the controller shelf.
-
Turn on the two power switches on the controller shelf.
-
Check the LEDs on each controller.
-