Requirements for E2800 HIC replacement
Before you add, upgrade, or replace a host interface card (HIC) in an E2800, review the requirements and considerations.
Procedure overview
The steps to replace a HIC depend on whether you have one or two controllers, as follows:
If your storage array has… | You must… |
---|---|
One controller (E2812 or E2824 simplex) |
|
Two controllers (E2860, E2812 or E2824 duplex) |
|
Requirements for adding, upgrading, or replacing a HIC
If you plan to add, upgrade, or replace a host interface card (HIC), keep the following requirements in mind.
-
You have scheduled a downtime maintenance window for this procedure. The power must be off when you install HICs, so you cannot access data on the storage array until you have successfully completed this procedure. (In a duplex configuration, this is because both controllers must have the same HIC configuration when they are powered on.)
-
You have one or two HICs, based on whether you have one or two controllers in your storage array. The HICs must be compatible with your controllers.
If you have a duplex configuration (two controllers), the HICs installed in the two controller canisters must be identical. The presence of mismatched HICs causes the controller with the replacement HIC to lock down when you bring it online.
-
You have all cables, transceivers, switches, and host bus adapters (HBAs) needed to connect the new host ports.
For information about compatible hardware, refer to the NetApp Interoperability Matrix or the NetApp Hardware Universe.
-
You have an ESD wristband, or you have taken other antistatic precautions.
-
You have a #1 Phillips screwdriver.
-
You have labels to identify each cable that is connected to the controller canister.
-
You have a management station with a browser that can access SANtricity System Manager for the controller. (To open the System Manager interface, point the browser to the controller's domain name or IP address.)