Test configuration
The following figure shows the test configuration. We used the NetApp AFF C190 storage system and two Lenovo ThinkSystem SE350 servers (each with one NVIDIA T4 accelerator). These components are connected through a 10GbE network switch. The network storage holds validation/test datasets and pretrained models. The servers provide computational capability, and the storage is accessed over NFS protocol.
This section describes the tested configurations, the network infrastructure, the SE350 server, and the storage provisioning details. The following table lists the base components for the solution architecture.
Solution components | Details |
---|---|
Lenovo ThinkSystem servers |
|
|
|
Entry-level NetApp AFF storage system (HA pair) |
|
The following table lists the storage configuration: AFF C190 with 2RU, 24 drive slots.
Controller | Aggregate | FlexGroup volume | Aggregatesize | Volumesize | Operating systemmount point |
---|---|---|---|---|---|
Controller1 |
Aggr1 |
/netapplenovo_AI_fg |
8.42TiB |
15TB |
/netapp_lenovo_fg |
Controller2 |
Aggr2 |
8.42TiB |
The /netappLenovo_AI_fg folder contains the datasets used for model validation.
The figure below shows the test configuration. We used the NetApp EF280 storage system and two Lenovo ThinkSystem SE350 servers (each with one NVIDIA T4 accelerator). These components are connected through a 10GbE network switch. The network storage holds validation/test datasets and pretrained models. The servers provide computational capability, and the storage is accessed over NFS protocol.
The following table lists the storage configuration for EF280.
Controller | Volume Group | Volume | Volumesize | DDPsize | Connection method |
---|---|---|---|---|---|
Controller1 |
DDP1 |
Volume 1 |
8.42TiB |
16TB |
SE350-1 to iSCSI LUN 0 |
Controller2 |
Volume 2 |
8.42TiB |
SE350-2 to iSCSI LUN 1 |