Skip to main content
OnCommand Insight

Brocade Sphereon/Intrepid Switch data source

Contributors

OnCommand Insight uses the Brocade Sphereon/Intrepid Switch (SNMP) data source to discover inventory for Brocade Sphereon or Intrepid switches.

Requirements

Note

This data collector not available starting with OnCommand Insight 7.3.11.

  • There must be IP connectivity to all switches in the fabric. If you select the Discover all switches in the fabric check box, OCI identifies all the switches in the fabric; however, it needs IP connectivity to these additional switches to discover them.

  • Read-only community string if using SNMP V1 or SNMP V2.

  • HTTP access to the switch to obtain zoning information.

  • Access validation by running the snmpwalk utility to the switch (see <install_path\>\bin\).

Configuration

Field

Description

Sphereon Switch

IP address or fully-qualified domain name of the switch

SNMP Version

SNMP version

SNMP Community

SNMP read-only community string used to access the switch

User Name

SMI-S user name for the switch (SNMP v3 only)

Password

SMI-S password for the switch (SNMP v3 only)

Advanced configuration

Field

Description

Inventory Poll Interval (min)

Interval between inventory polls (default 15 minutes)

SNMP Auth Protocol

SNMP authentication protocol (SNMPv3 only)

SNMP Privacy Protocol

SNMP privacy protocol (SNMPv3 only)

SNMP Privacy Password

SNMP privacy password

SNMP Number of Retries

Number of SNMP retry attempts

SNMP Timeout (ms)

SNMP timeout (default 5000 ms)

Fabric Name

Fabric name to be reported by the data source. Leave blank to report the fabric name as WWN.

Enable Trapping

Select to enable acquisition upon receiving an SNMP trap from the device. If you select enable trapping, you must also activate SNMP.

Minimum Time Between Ttraps (seconds)

Minimum time between acquisition attempts triggered by traps (default 10 seconds)

Performance Poll Interval (sec)