storage switch add
Add a back-end switch for monitoring
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The storage switch add command enables you to add FC switches for SNMP monitoring in a MetroCluster configuration. Front end switches should not be added for monitoring and will result in a Monitor Status Error condition.
Parameters
-address <IP Address>- FC Switch Management IP Address-
This parameter specifies the IP address of the back-end switch that is added for monitoring.
[-snmp-version {SNMPv1|SNMPv2c|SNMPv3}]- Supported SNMP Version-
This parameter specifies the SNMP version that Data ONTAP uses to communicate with the back-end switch that is added for monitoring. The default SNMP version is SNMPv2c.
- {
[-snmp-community <text>]- (DEPRECATED)-SNMPv2c Community or SNMPv3 Username -
This parameter is deprecated and may be removed in a future release of Data ONTAP. Use -snmp-community-or-usernameinstead.This parameter specifies the SNMPv2c community set or SNMPv3 username on the switch that is added for monitoring.
- |
[-snmp-community-or-username <text>]- SNMPv2c Community or SNMPv3 Username } -
This parameter specifies the SNMPv2c community set or SNMPv3 username on the switch that is added for monitoring.
[-veto-backend-fabric-check {true|false}]- Veto Back-end Fabric Check? (privilege: advanced)-
If specified, the
storage switch addcommand will not check if the switch is present in the MetroCluster's back-end fabric. By default, it does not let you add switches that are not present. [-blades <integer>,…]- Cisco Director Class Switch Blades to Monitor-
This parameter specifies the blades to monitor on the back-end switch that is added for monitoring. It is only applicable to director-class switches.
Examples
The following command adds a back-end switch with IP Address 10.226.197.34 for monitoring:
cluster1::> storage switch add -address 10.226.197.34 -snmp-community-or-username public
cluster1::> storage switch show
Symbolic Is Monitor
Switch Name Vendor Model Switch WWN Monitored Status
----------- -------- ------- ---------- ---------------- --------- -------
Cisco_10.226.197.34
mcc-cisco-8Gb-fab-4
Cisco DS-C9148-16P-K9
2000547fee78f088 true ok
mcc-cisco-8Gb-fab-1
mcc-cisco-8Gb-fab-1
Cisco - - false -
mcc-cisco-8Gb-fab-2
mcc-cisco-8Gb-fab-2
Cisco - - false -
mcc-cisco-8Gb-fab-3
mcc-cisco-8Gb-fab-3
Cisco - - false -
4 entries were displayed.
cluster1::>
The following command adds a Cisco Director Class switch for monitoring. Data ONTAP uses SNMPv3 and 'snmpuser1' username to communicate with this switch.
cluster1::> storage switch add -address 10.228.56.208 -snmp-version SNMPv3 -snmp-community-or-username snmpuser1 -blades 3,4