storage switch show
Display switch information
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The storage switch show
command displays information about all the storage switches in the MetroCluster configuration. The back-end switches must have been previously added for monitoring using the storage switch add command. If no parameters are specified, the default command displays the following information about the storage switches:
-
Switch
-
Symbolic Name
-
Vendor
-
Model
-
Switch WWN
-
Is Monitored
-
Monitor Status
To display detailed profile information about a single storage switch, use the -switch-name
parameter.
Parameters
- {
[-fields <fieldname>,…]
-
Displays the specified fields for all the storage switches, in column style output.
- |
[-connectivity ]
-
Displays the following details about the connectivity from the storage switch to connected entities:
-
Port name
-
Port operating mode
-
Port world wide name
-
Peer port world wide name
-
Peer type
-
Additional information about peer
Displays the following details about the connectivity from the node to the storage switch:
-
Node name
-
Adapter name
-
Switch port name
-
Switch port speed
-
Adapter type
-
- |
[-cooling ]
-
Displays the following details about the fans and temperature sensors on the storage switch:
-
Fan name
-
Fan speed in rotations per minute (RPM)
-
Fan operational status
-
Temperature sensor name
-
Temperature sensor reading in Celsius ©
-
Temperature sensor status
-
- |
[-error ]
-
Displays the errors related to the storage switch.
- |
[-port ]
-
Displays the following details about the storage switch ports:
-
Port name
-
Port world wide name
-
Port administrative status
-
Port operational status
-
Port operating mode
-
Whether SFP is present in the port
-
Port speed in gigabits per second (Gbps)
-
Port BB credit
-
Peer port world wide name
-
- |
[-power ]
-
Displays the following details about the storage switch power supplies:
-
Power supply name
-
Power supply serial number
-
Power supply operational status
-
- |
[-san-config ]
-
Displays the following details about the Virutal Storage Area Networks (VSAN) and Zones of the storage switch:
-
VSAN identifier
-
VSAN name
-
VSAN operational status
-
Type of load balancing configured for the VSAN
-
Where in-order-delivery set for the VSAN
-
Whether the auto power reset of the PSU is enabled
-
VAN member switch name and port
-
Zone name
-
VSAN ID of the zone
-
Zone member switch name and port
-
Zone member port id
-
Zone member port world wide name
-
- |
[-sfp ]
-
Displays the following details about the storage switch ports Small Formfactor Pluggable (SFP):
-
Port name
-
Type of SFP
-
SFP transmitter type
-
SFP vendor
-
SFP part number
-
SFP serial number
-
- |
[-stats ]
-
Displays the following details about the storage switch ports:
-
Port name
-
Frames received through the port (Rx Frames)
-
Frames transmitted through the port (Tx Frames)
-
Octets received through the port (Rx Octets)
-
Octets transmitted through the port (Tx Octets)
-
Port error frames
-
- |
[-instance ]
} -
Displays expanded information about all the storage switches in the system. If a storage switch is specified, then this parameter displays the same detailed information for the storage switch you specify as does the -switch-name parameter.
[-switch-name <text>]
- FC Switch Name-
Displays information only about the storage switches that match the name you specify.
[-switch-wwn <text>]
- Switch World Wide Name-
Displays information only about the storage switches that match the switch wwn you specify.
[-switch-symbolic-name <text>]
- Switch Symbolic Name-
Displays information only about the storage switches that match the switch symbolic name you specify.
[-switch-fabric-name <text>]
- Fabric Name-
Displays information only about the storage switches that match the switch fabric you specify.
[-domain-id <integer>]
- Switch Domain ID-
Displays information only about the storage switches that match the switch domain id you specify.
[-switch-role {unknown|primary|subordinate}]
- Switch Role in Fabric-
Displays information only about the storage switches that match the switch role you specify.
[-snmp-version {SNMPv1|SNMPv2c|SNMPv3}]
- SNMP Version-
Displays information only about the storage switches that match the switch SNMP version you specify.
[-switch-model <text>]
- Switch Model-
Displays information only about the storage switches that match the switch model you specify.
[-switch-vendor {unknown|Brocade|Cisco}]
- Switch Vendor-
Displays information only about the storage switches that match the switch vendor you specify.
[-fw-version <text>]
- Switch Firmware Version-
Displays information only about the storage switches that match the switch firmware version you specify.
[-serial-number <text>]
- Switch Serial Number-
Displays information only about the storage switches that match the switch serial number you specify.
[-switch-ipaddress <IP Address>]
- Switch IP Address-
Displays information only about the storage switches that match the switch IP address you specify.
[-switch-status {unknown|ok|error}]
- Switch Status-
Displays information only about the storage switches that match the switch status you specify.
[-snmp-community <text>]
- (DEPRECATED)-SNMPv2c Community or SNMPv3 Username-
This parameter is deprecated and may be removed in a future release of Data ONTAP. Use -snmp-community-or-username
instead.Displays information only about the storage switches that match the switch SNMPv2c community or SNMPv3 username you specify.
[-snmp-community-or-username <text>]
- SNMPv2c Community or SNMPv3 Username-
Displays information only about the storage switches that match the switch SNMPv2c community or SNMPv3 username you specify.
[-profile-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Profile Data Last Successful Refresh Timestamp-
Displays information only about the storage switches that match the profile data last successful refresh timestamp you specify.
[-is-monitoring-enabled {true|false}]
- Is Monitoring Enabled for Switch-
Displays information only about the storage switches that match the switch monitoring value you specify.
[-blades <integer>,…]
- Director-Class Switch Blades to Monitor-
Displays information only about the storage switches that match the blade value you specify.
[-engine-id <Hex String>]
- Engine ID of SNMPv3 Capable Switch-
Displays information only about the storage switches that match the SNMPv3 engine-id you specify.
[-psu-name-list <text>,…]
- Switch Power Supply Name List-
Displays information only about the storage switches that have the power supply units with the names you specify.
[-psu-serial-number-list <text>,…]
- Switch Power Supply Serial Number List-
Displays information only about the storage switches that have the power supply units with the serial numbers you specify.
[-psu-status-list {unknown|normal|warning|faulty|not-present}]
- Switch Power Supply Status List-
Displays information only about the storage switches that have the power supply units with the statuses you specify.
[-psu-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Power Supply Data Last Successful Refresh Timestamp-
Displays information only about the storage switches that match the power supply unit data last successful refresh timestamp you specify.
[-temp-sensor-name-list <text>,…]
- Switch Temperature Sensor Name List-
Displays information only about the storage switches that have the temperature sensors with the names you specify.
[-temp-sensor-reading-list <integer>,…]
- Switch Temperature Sensor Reading © List-
Displays information only about the storage switches that have the temperature sensors with the readings you specify.
[-temp-sensor-status-list {unknown|normal|warning|critical}]
- Switch Temperature Sensor Status List-
Displays information only about the storage switches that have the temperature sensors with the statuses you specify.
[-temp-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Temperature Sensor Data Last Successful Refresh Timestamp-
Displays information only about the storage switches that match the temperature sensor data last successful refresh timestamp you specify.
[-fan-name-list <text>,…]
- Switch Fan Name List-
Displays information only about the storage switches that match the fans with the names you specify.
[-fan-rpm-list <integer>,…]
- Switch Fan Speed (RPM) List-
Displays information only about the storage switches that match the fans with the RPM speeds you specify.
[-fan-status-list {unknown|operational|failed|not-operational|not-present}]
- Switch Fan Operational Status List-
Displays information only about the storage switches that match the fans with the statuses you specify.
[-fan-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Fan Data Last Successful Refresh Timestamp-
Displays information only about the storage switches that match the fan data last successful refresh timestamp you specify.
[-vsan-index-list <integer>,…]
- Switch VSAN Index List-
Displays information only about the storage switches that have the VSANs with the indexes you specify.
[-vsan-name-list <text>,…]
- Switch VSAN Name List-
Displays information only about the storage switches that have the VSANs with the names you specify.
[-vsan-oper-status-list {up|down}]
- Switch VSAN Operational Status List-
Displays information only about the storage switches that have the VSANs with the operational statuses you specify.
[-vsan-load-balancing-type-list {src-id-dest-id|src-id-dest-id-ox-id}]
- Switch VSAN Load balancing Type List-
Displays information only about the storage switches that have the VSANs with the load balancing types you specify.
[-is-vsan-iod-list {true|false}]
- Is In-order Delivery Set for VSAN List-
Displays information only about the storage switches that have the VSANs with the IOD setting you specify.
[-vsan-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch VSAN Data Last Successful Refresh Timestamp-
Displays information only about the storage switches that match the VSAN data last successful refresh timestamp you specify.
[-member-switch-name-list <text>,…]
- Member Switch List-
Displays information only about the storage switches that have the VSANs with the member switch names you specify.
[-member-switch-port-name-list <text>,…]
- Member Switch Port Name List-
Displays information only about the storage switches that have the VSANs with the memeber switch port names you specify.
[-vsan-id-list <integer>,…]
- Zone VSAN ID List-
Displays information only about the storage switches that have the VSANs with the IDs you specify.
[-zone-name-list <text>,…]
- Switch Zone Name List-
Displays information only about the storage switches that have the zones with the names you specify.
[-zone-member-sw-domain-id-list <integer>,…]
- Zone Member Switch Port Domain ID List-
Displays information only about the storage switches that have the zones with the member switch domain ids you specify.
[-zone-member-port-name-list <text>,…]
- Zone Member Port List-
Displays information only about the storage switches that have the zones with the port names you specify.
[-zone-member-port-wwn-list <text>,…]
- Zone Member WWPN List-
Displays information only about the storage switches that have the zones with the port WWNs you specify.
[-zone-member-port-switch-name-list <text>,…]
- Zone Member Switch WWN List-
Displays information only about the storage switches that have the zones with the member port hosting switch names you specify.
[-zone-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Zone Data Last Successful Refresh Timestamp-
Displays information only about the storage switches that match the zone data last successful refresh timestamp you specify.
[-zone-member-wwn-list <text>,…]
- Zone Member WWN List-
Displays information only about the storage switches that have the zones with the member WWNs you specify.
[-zone-member-port-id-list <text>,…]
- Zone Member Port ID List-
Displays information only about the storage switches that have the zones with the member port ids you specify.
[-port-wwn-list <text>,…]
- Switch Port World Wide Name (WWPN) List-
Displays information only about the storage switches that have the ports with the WWNs you specify.
[-port-name-list <text>,…]
- Switch Port Name List-
Displays information only about the storage switches that have the ports with the names you specify.
[-port-admin-status-list {unknown|enabled|disabled}]
- Switch Port Admin Status List-
Displays information only about the storage switches that have the ports with administrative statuses you specify.
[-port-oper-status-list {unknown|online|offline}]
- Switch Port Operational Status List-
Displays information only about the storage switches that have the ports with operational statuses you specify.
[-port-mode-list {unknown|auto|F-port|FL-port|E-port|TE-port|U-port|G-port}]
- Switch Port Mode List-
Displays information only about the storage switches that have the ports with the operating modes you specify.
[-port-oper-speed-list <integer>,…]
- Switch Port Current Speed (in Gbits/sec) List-
Displays information only about the storage switches that have the ports with the operational speeds you specify.
[-port-bb-credit-list <integer>,…]
- Switch Port BB Credit List-
Displays information only about the storage switches that have the ports with the BB credits you specify.
[-port-sfp-present-list {true|false}]
- Switch Port Is SFP Present List-
Displays information only about the storage switches that have the ports with the SFP present values you specify.
[-port-peer-wwpn-list <text>,…]
- Switch Port Peer WWPN List-
Displays information only about the storage switches that have the ports with the peer port WWPNs you specify.
[-port-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Port Data Last Successful Refresh Timestamp-
Displays information only about the storage switches that match the port data last successful refresh timestamp you specify.
[-port-stat-name-list <text>,…]
- Switch Port Name List-
Displays information only about the storage switches that have the ports with the names you specify.
[-port-tx-frames-list <integer>,…]
- Switch Port Transmitted Frame Count List-
Displays information only about the storage switches that have the ports with the transmitted frames values you specify.
[-port-rx-frames-list <integer>,…]
- Switch Port Received Frame Count List-
Displays information only about the storage switches that have the ports with the received frames values you specify.
[-port-tx-octets-list <integer>,…]
- Switch Port Total Transmitted Octets List-
Displays information only about the storage switches that have the ports with the transmitted octets values you specify.
[-port-rx-octets-list <integer>,…]
- Switch Port Total Received Octets List-
Displays information only about the storage switches that have the ports with the received octets values you specify.
[-port-frame-error-list <integer>,…]
- Switch Port Frame Error Count List-
Displays information only about the storage switches that have the ports with the error frame values you specify.
[-port-stat-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Port Stat Data Last Update Timestamp-
Displays information only about the storage switches that match the port statistics data last successful refresh timestamp you specify.
[-sfp-port-name-list <text>,…]
- Switch Port Name List-
Displays information only about the storage switches that have the ports with the names you specify.
[-sfp-type-list {unknown|other|gbic|embedded|glm|gbic-with-serial-id|gbic-without-serial-id|sfp-with-serial-id|sfp-without-serial-id|xfp|x2-short|x2-medium|x2-tall|xpak-short|xpak-medium|xpak-tall|xenpak|sfp-dw-dm|qsfp|x2-dw-dm|gbic-not-installed|small-form-factor}]
- Switch Port SFP Type List-
Displays information only about the storage switches that have the ports with the SFP types you specify.
[-sfp-tx-type-list {unknown|long-wave-laser|short-wave-laser|long-wave-laser-cost-reduced|electrical|ten-gig-base-sr|ten-gig-base-lr|ten-gig-base-er|ten-gig-base-lx4|ten-gig-base-sw|ten-gig-base-lw|ten-gig-base-ew}]
- Switch Port SFP Transmitter Type List-
Displays information only about the storage switches that have the ports with the SFP transmitter types you specify.
[-sfp-vendor-list <text>,…]
- Switch Port SFP Vendor List-
Displays information only about the storage switches that have the ports with the SFP vendors you specify.
[-sfp-part-number-list <text>,…]
- Switch Port SFP Part Number List-
Displays information only about the storage switches that have the ports with the SFP part numbers you specify.
[-sfp-serial-number-list <text>,…]
- Switch Port SFP Serial Number List-
Displays information only about the storage switches that have the ports with the SFP serial numbers you specify.
[-sfp-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Port SFP Data Last Successful Refresh Timestamp-
Displays information only about the storage switches that match the port SFP data last successful refresh timestamp you specify.
[-switch-error-text-list <text>,…]
- Switch Error Text List-
Displays information only about the storage switches that have the errors you specify.
[-conn-switch-port-name-list <text>,…]
- Switch Port Name List-
Displays information only about the storage switches that have the ports with the names you specify.
[-conn-switch-port-mode-list {unknown|auto|F-port|FL-port|E-port|TE-port|U-port|G-port}]
- Switch Port Operating Mode List-
Displays information only about the storage switches that have the ports with the operating modes you specify.
[-conn-switch-port-wwn-list <text>,…]
- Switch Port WWN List-
Displays information only about the storage switches that have the ports with the WWNs you specify.
[-conn-switch-port-peer-port-wwn-list <text>,…]
- Switch Port Peer Port WWN List-
Displays information only about the storage switches that have the ports with the peer port WWNs you specify.
[-conn-switch-port-peer-info-list <text>,…]
- Switch Port Peer Host & Port Name List-
Displays information only about the storage switches that have the ports with the peer information values you specify.
[-conn-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Connectivity Data Last Successful Refresh Timestamp-
Displays information only about the storage switches that match the switch connectivity data last successful refresh timestamp you specify.
[-conn-switch-port-peer-type-list {unknown|bridge|switch|fcp-adapter|fcvi-adapter}]
- Switch Port Peer Type List-
Displays information only about the storage switches that have the ports connected to the peer types you specify.
[-switch-port-name-list <text>,…]
- Switch Port Name List-
Displays information only about the storage switches that have the ports with the names you specify.
[-switch-port-speed-list <integer>,…]
- Switch Port Speed (in Gbps) List-
Displays information only about the storage switches that have the ports with the speeds you specify.
[-node-name-list <nodename>,…]
- Node Name List-
Displays information only about the storage switches that are connected to the nodes you specify.
[-adapter-name-list <text>,…]
- Node Adapter Name List-
Displays information only about the storage switches that are connected to the adapters you specify.
[-adapter-port-name-list <text>,…]
- Node Adapter Port Name List-
Displays information only about the storage switches that are connected to the adapter ports you specify.
[-adapter-type-list {unknown|FCP-Initiator|FC-VI|FCP-Target}]
- Node Adapter Type List-
Displays information only about the storage switches that are connected to the types of adapters you specify.
[-path-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Path Data Last Successful Refresh Timestamp-
Displays information only about the storage switches that match the node to switch path data last successful refresh timestamp you specify.
[-name-list <text>,…]
- Switch Name List-
Displays information only about the storage switches that match the names you specify.
[-domain-id-list <integer>,…]
- Switch Domain ID List-
Displays information only about the storage switches that match the domain ids you specify.
[-wwn-list <text>,…]
- Switch WWN List-
Displays information only about the storage switches that match the switch WWNs you specify.
[-role-list {unknown|primary|subordinate}]
- Switch Role in Fabric List-
Displays information only about the storage switches that match the switch roles you specify.
[-address-list <IP Address>,…]
- Switch IP Address List-
Displays information only about the storage switches that match the switch IP addresses you specify.
Examples
The following example displays information about all storage switches:
cluster::>storage switch show Symbolic Is Monitor Switch Name Vendor Model Switch WWN Monitored Status ----------- -------- ------- ---------- ---------------- --------- ------- Cisco_10.226.197.34 mcc-cisco-8Gb-fab-4 Cisco DS-C9148-16P-K9 2000547fee78f088 true ok Cisco_10.226.197.35 mcc-cisco-8Gb-fab-3 Cisco DS-C9148-16P-K9 2000547fee78f0f0 true ok Cisco_10.226.197.36 mcc-cisco-8Gb-fab-2 Cisco DS-C9148-16P-K9 2000547fee78efb0 true ok Cisco_10.226.197.37 mcc-cisco-8Gb-fab-1 Cisco DS-C9148-16P-K9 2000547fee78f0d8 true ok 4 entries were displayed. cluster::>
The following example displays connectivity (switch to peer and node to switch) information about all storage switches:
cluster::> storage switch show -connectivity Switch Name: Cisco_10.226.197.36 Switch WWN: 2000547fee78efb0 Fabric WWN: 2001547fee78efb1 Vendor: Cisco Model: DS-C9148-16P-K9 Errors: - Last Update Time: 7/31/2014 14:16:42 -04:00 Connectivity: Port Name Port Mode Port WWN Peer Port WWN Peer Type Peer Info --------- --------- ---------------- ---------------- ------------ --------- fc1/1 F-port 2001547fee78efb0 2100001086607d34 unknown unknown fc1/3 F-port 2003547fee78efb0 21000024ff3dd9cb unknown unknown fc1/4 F-port 2004547fee78efb0 21000024ff3dda8d unknown unknown fc1/5 F-port 2005547fee78efb0 500a0980009af880 unknown unknown fc1/6 F-port 2006547fee78efb0 500a0981009af370 unknown unknown fc1/11 TE-port 200b547fee78efb0 200b547fee78f088 switch Cisco_10.226.197.34:fc1/11 fc1/12 TE-port 200c547fee78efb0 200c547fee78f088 switch Cisco_10.226.197.34:fc1/12 fc1/13 F-port 200d547fee78efb0 2100001086609e22 unknown unknown fc1/15 F-port 200f547fee78efb0 21000024ff3dd91b unknown unknown fc1/16 F-port 2010547fee78efb0 21000024ff3dbef5 unknown unknown fc1/17 F-port 2011547fee78efb0 500a0981009afda0 unknown unknown fc1/18 F-port 2012547fee78efb0 500a0981009a9160 unknown unknown fc1/25 F-port 2019547fee78efb0 21000010866037e8 bridge ATTO_10.226.197.17:1 fc1/27 F-port 201b547fee78efb0 21000024ff3dd9d3 fcvi-adapter dpg-mcc-3240-15-a1:fcvi_device_1 fc1/28 F-port 201c547fee78efb0 21000024ff3dbe3d fcvi-adapter dpg-mcc-3240-15-a2:fcvi_device_1 fc1/29 F-port 201d547fee78efb0 500a0980009ae0a0 fcp-adapter dpg-mcc-3240-15-a2:0c fc1/30 F-port 201e547fee78efb0 500a0981009aef40 fcp-adapter dpg-mcc-3240-15-a1:0d Last Update Time: 7/31/2014 14:26:48 -04:00 Path: Switch Port Node Adapter Switch Port Speed Adapter Type -------------------- -------------- ----------- ------- -------------- dpg-mcc-3240-15-a1 0d fc1/30 4Gbps FCP-Initiator dpg-mcc-3240-15-a1 fcvi_device_1 fc1/27 8Gbps FC-VI dpg-mcc-3240-15-a2 0c fc1/29 4Gbps FCP-Initiator dpg-mcc-3240-15-a2 fcvi_device_1 fc1/28 8Gbps FC-VI
The following command displays cooling (temperature sensors and fans) information about all storage switches:
cluster::>storage switch show -cooling Switch Name: Cisco_10.226.197.34 Switch WWN: 2000547fee78f088 Fabric WWN: 2001547fee78efb1 Vendor: Cisco Model: DS-C9148-16P-K9 Errors: - Last Update Time: 7/31/2014 14:26:58 -04:00 Fans: Fan RPM Status ------------ -------- --------------- Fan Module-1 - operational Fan Module-2 operational Fan Module-3 operational Fan Module-4 operational Last Update Time: 7/31/2014 14:27:10 -04:00 Temperature Sensors: Sensor Temp (C) Status --------------- -------- -------- module-1 Outlet 27 normal module-1 Outlet 29 normal module-1 Intake 26 normal module-1 Intake 28 normal
The following command displays the error information about all storage switches:
cluster::> storage switch show -error Switch Name: Cisco_10.226.197.34 Switch WWN: 2000547fee78f088 ------------------------------------------------------------------------------- Cisco_10.226.197.34(2000547fee78f088): Switch is Unreachable over Management Network. Switch Name: Cisco_10.226.197.35 Switch WWN: 2000547fee78f0f0 ------------------------------------------------------------------------------- Cisco_10.226.197.35(2000547fee78f0f0): Switch is Unreachable over Management Network. Switch Name: Cisco_10.226.197.36 Switch WWN: 2000547fee78efb0 ------------------------------------------------------------------------------- Cisco_10.226.197.36(2000547fee78efb0): Switch is Unreachable over Management Network. Switch Name: Cisco_10.226.197.37 Switch WWN: 2000547fee78f0d8 ------------------------------------------------------------------------------- Cisco_10.226.197.37(2000547fee78f0d8): Switch is Unreachable over Management Network. 4 entries were displayed.
The following command displays the detailed information about all the storage switches:
cluster::> storage switch show -instance Switch Name: Cisco_10.226.197.34 Switch Domain: - Switch Role: - Switch WWN: 2000547fee78f088 Fabric WWN: 2001547fee78efb1 Vendor: Cisco Model: DS-C9148-16P-K9 Firmware Version: 6.2(1) Management IP: 10.226.197.34 Errors: Cisco_10.226.197.34(2000547fee78f088): Switch is Unreachable over Management Network. Last Update Time: 7/31/2014 14:41:28 -04:00 Fabric: Switch Name Domain WWN Role IP Address --------------------------- ------ ---------------- ----------- --------------- Cisco_10.226.197.34 0 2000547fee78f088 unknown 10.226.197.34 Cisco_10.226.197.36 0 2000547fee78efb0 unknown 10.226.197.36
The following command displays port information about all storage switches:
cluster::> storage switch show -port Switch Name: Cisco_10.226.197.34 Switch WWN: 2000547fee78f088 Fabric WWN: 2001547fee78efb1 Vendor: Cisco Model: DS-C9148-16P-K9 Errors: - Last Update Time: 7/31/2014 14:26:58 -04:00 Ports: Admin Oper SFP Speed BB Port Name Port WWN Status Status Port Mode Present (Gbps) Credit PeerPortWWN --------- -------- -------- ------- --------- ------- ------ ------ ----------- fc1/1 2001547fee78f088 enabled online F-port true 8 1 2100001086608b76 fc1/2 2002547fee78f088 enabled offline auto true 0 1 fc1/3 2003547fee78f088 enabled online F-port true 8 1 21000024ff48edd9 fc1/4 2004547fee78f088 enabled online F-port true 8 1 21000024ff3dd981 fc1/5 2005547fee78f088 enabled online F-port true 4 1 500a098001057f98 fc1/6 2006547fee78f088 enabled online F-port true 4 1 500a098101069778 fc1/7 2007547fee78f088 enabled offline auto true 0 1 fc1/8 2008547fee78f088 enabled offline auto true 0 1 fc1/9 2009547fee78f088 enabled offline auto true 0 1 fc1/10 200a547fee78f088 enabled offline auto true 0 32 fc1/11 200b547fee78f088 enabled offline TE-port true 8 32 200b547fee78efb0 fc1/12 200c547fee78f088 enabled offline TE-port true 8 32 200c547fee78efb0 fc1/13 200d547fee78f088 enabled online F-port true 8 32 2100001086609c2e fc1/14 200e547fee78f088 enabled offline auto true 0 32 fc1/15 200f547fee78f088 enabled offline auto true 0 32 fc1/16 2010547fee78f088 enabled offline auto true 0 32 fc1/17 2011547fee78f088 enabled offline auto true 0 32 fc1/18 2012547fee78f088 enabled offline auto true 0 32 fc1/19 2013547fee78f088 enabled offline auto true 0 32 fc1/20 2014547fee78f088 enabled offline auto true 0 1 fc1/21 2015547fee78f088 enabled offline auto true 0 1 fc1/22 2016547fee78f088 enabled offline auto true 0 32 fc1/23 2017547fee78f088 enabled offline auto true 0 32 fc1/24 2018547fee78f088 enabled offline auto true 0 32 fc1/25 2019547fee78f088 enabled online F-port true 8 32 2100001086609c06 fc1/26 201a547fee78f088 enabled offline auto true 0 32 fc1/27 201b547fee78f088 enabled online F-port true 8 32 21000024ff48ea93 fc1/28 201c547fee78f088 enabled online F-port true 8 32 21000024ff48eacf fc1/29 201d547fee78f088 enabled online F-port true 4 32 500a098101484340 fc1/30 201e547fee78f088 enabled online F-port true 4 32 500a09810147e700 fc1/31 201f547fee78f088 enabled offline auto true 0 32 fc1/32 2020547fee78f088 enabled offline auto true 0 1 fc1/33 2021547fee78f088 enabled offline auto true 0 1 fc1/34 2022547fee78f088 enabled offline auto true 0 32 fc1/35 2023547fee78f088 enabled offline auto true 0 32 fc1/36 2024547fee78f088 enabled offline auto true 0 32 fc1/37 2025547fee78f088 enabled offline auto true 0 32 fc1/38 2026547fee78f088 enabled offline auto true 0 32 fc1/39 2027547fee78f088 enabled offline auto true 0 32 fc1/40 2028547fee78f088 enabled offline auto true 0 32 fc1/41 2029547fee78f088 enabled offline auto true 0 32 fc1/42 202a547fee78f088 enabled offline auto true 0 32 fc1/43 202b547fee78f088 enabled offline auto true 0 32 fc1/44 202c547fee78f088 enabled offline auto true 0 32 fc1/45 202d547fee78f088 enabled offline auto true 0 32 fc1/46 202e547fee78f088 enabled offline auto true 0 32 fc1/47 202f547fee78f088 enabled offline auto true 0 32 fc1/48 2030547fee78f088 enabled offline auto true 0 0 port-channel 1 2401547fee78f088 enabled offline auto true 0 0 port-channel 2 2402547fee78f088 enabled offline auto true 0 0 port-channel 3 2403547fee78f088 enabled offline auto true 0 0 port-channel 4 2404547fee78f088 enabled offline auto true 0 0 port-channel 5 2405547fee78f088 enabled offline auto true 0 0 port-channel 6 2406547fee78f088 enabled offline auto true 0 0 port-channel 7 2407547fee78f088 enabled offline auto true 0 0 port-channel 8 2408547fee78f088 enabled offline auto true 0 0 port-channel 9 2409547fee78f088 enabled offline auto true 0 0 port-channel 10 240a547fee78f088 enabled offline auto true 0 0 port-channel 11 240b547fee78f088 enabled offline auto true 0 0 port-channel 12 240c547fee78f088 enabled offline auto true 0 0 sup-fc0 enabled online unknown true 1 0
The following command displays power supply unit information about all storage switches:
cluster::> storage switch show -power Switch Name: Cisco_10.226.197.34 Switch WWN: 2000547fee78f088 Fabric WWN: 2001547fee78efb1 Vendor: Cisco Model: DS-C9148-16P-K9 Errors: - Last Update Time: 7/31/2014 14:41:49 -04:00 Power Supplies: Power Supply Serial Number Status --------------- ------------- ----------- 300.00W 110v AC PAC15494TBZ normal 300.00W 110v AC PAC15494T4D normal
The following command displays san configuration (VSANs and Zones) information about all storage switches:
cluster::> storage switch show -san-config Switch Name: Cisco_10.226.197.34 Switch WWN: 2000547fee78f088 Fabric WWN: 2001547fee78efb1 Vendor: Cisco Model: DS-C9148-16P-K9 Errors: - Last Update Time: 7/31/2014 14:41:49 -04:00 VSAN Configuration: Oper VSAN ID Vsan Name Status Load Balancing isIOD ------- ------------------------ ------ --------------- ----- 1 VSAN0001 up src-id-dest-id true 2 dpg_13_storage up src-id-dest-id-ox-id true 3 dpg_13_fcvi down src-id-dest-id-ox-id true 10 dpg_mcc_13_fab1_fcvi up src-id-dest-id true 20 dpg_mcc_13_fab1_storage up src-id-dest-id-ox-id true 30 dpg_mcc_13_fab2_fcvi up src-id-dest-id true 40 VSAN0040 up src-id-dest-id true 70 dpg_mcc_14_fcvi up src-id-dest-id true 80 dpg_mcc_14_storage up src-id-dest-id-ox-id true 110 dpg_mcc_15_fcvi up src-id-dest-id-ox-id true 120 dpg_mcc_15_storage up src-id-dest-id-ox-id true 4094 isolated_vsan down src-id-dest-id-ox-id true VSAN Membership: VSAN ID Switch Name Switch Port Name ------- -------------------- ---------------- 1 Cisco_10.226.197.34 fc1/2 1 Cisco_10.226.197.34 fc1/7 1 Cisco_10.226.197.34 fc1/8 1 Cisco_10.226.197.34 fc1/9 1 Cisco_10.226.197.34 fc1/10 1 Cisco_10.226.197.34 fc1/11 1 Cisco_10.226.197.34 fc1/12 1 Cisco_10.226.197.34 fc1/14 1 Cisco_10.226.197.34 fc1/19 1 Cisco_10.226.197.34 fc1/20 1 Cisco_10.226.197.34 fc1/21 1 Cisco_10.226.197.34 fc1/22 1 Cisco_10.226.197.34 fc1/23 1 Cisco_10.226.197.34 fc1/24 1 Cisco_10.226.197.34 fc1/31 1 Cisco_10.226.197.34 fc1/32 1 Cisco_10.226.197.34 fc1/33 1 Cisco_10.226.197.34 fc1/34 1 Cisco_10.226.197.34 fc1/35 1 Cisco_10.226.197.34 fc1/36 1 Cisco_10.226.197.34 fc1/37 1 Cisco_10.226.197.34 fc1/38 1 Cisco_10.226.197.34 fc1/39 1 Cisco_10.226.197.34 fc1/40 1 Cisco_10.226.197.34 fc1/41 1 Cisco_10.226.197.34 fc1/42 1 Cisco_10.226.197.34 fc1/43 1 Cisco_10.226.197.34 fc1/44 1 Cisco_10.226.197.34 fc1/45 1 Cisco_10.226.197.34 fc1/46 1 Cisco_10.226.197.34 fc1/47 1 Cisco_10.226.197.34 fc1/48 1 Cisco_10.226.197.34 port-channel 1 1 Cisco_10.226.197.34 port-channel 2 1 Cisco_10.226.197.34 port-channel 3 1 Cisco_10.226.197.34 port-channel 4 1 Cisco_10.226.197.34 port-channel 5 1 Cisco_10.226.197.34 port-channel 6 1 Cisco_10.226.197.34 port-channel 7 1 Cisco_10.226.197.34 port-channel 8 1 Cisco_10.226.197.34 port-channel 9 1 Cisco_10.226.197.34 port-channel 10 1 Cisco_10.226.197.34 port-channel 11 1 Cisco_10.226.197.34 port-channel 12 1 Cisco_10.226.197.36 fc1/2 1 Cisco_10.226.197.36 fc1/7 1 Cisco_10.226.197.36 fc1/8 1 Cisco_10.226.197.36 fc1/9 1 Cisco_10.226.197.36 fc1/10 1 Cisco_10.226.197.36 fc1/11 1 Cisco_10.226.197.36 fc1/12 1 Cisco_10.226.197.36 fc1/14 1 Cisco_10.226.197.36 fc1/19 1 Cisco_10.226.197.36 fc1/20 1 Cisco_10.226.197.36 fc1/21 1 Cisco_10.226.197.36 fc1/22 1 Cisco_10.226.197.36 fc1/23 1 Cisco_10.226.197.36 fc1/24 1 Cisco_10.226.197.36 fc1/26 1 Cisco_10.226.197.36 fc1/31 1 Cisco_10.226.197.36 fc1/32 1 Cisco_10.226.197.36 fc1/33 1 Cisco_10.226.197.36 fc1/34 1 Cisco_10.226.197.36 fc1/35 1 Cisco_10.226.197.36 fc1/36 1 Cisco_10.226.197.36 fc1/37 1 Cisco_10.226.197.36 fc1/38 1 Cisco_10.226.197.36 fc1/39 1 Cisco_10.226.197.36 fc1/40 1 Cisco_10.226.197.36 fc1/41 1 Cisco_10.226.197.36 fc1/42 1 Cisco_10.226.197.36 fc1/43 1 Cisco_10.226.197.36 fc1/44 1 Cisco_10.226.197.36 fc1/45 1 Cisco_10.226.197.36 fc1/46 1 Cisco_10.226.197.36 fc1/47 1 Cisco_10.226.197.36 fc1/48 30 Cisco_10.226.197.34 fc1/3 30 Cisco_10.226.197.34 fc1/4 30 Cisco_10.226.197.36 fc1/3 30 Cisco_10.226.197.36 fc1/4 40 Cisco_10.226.197.34 fc1/1 40 Cisco_10.226.197.34 fc1/5 40 Cisco_10.226.197.34 fc1/6 40 Cisco_10.226.197.36 fc1/1 40 Cisco_10.226.197.36 fc1/5 40 Cisco_10.226.197.36 fc1/6 70 Cisco_10.226.197.34 fc1/15 70 Cisco_10.226.197.34 fc1/16 70 Cisco_10.226.197.36 fc1/15 70 Cisco_10.226.197.36 fc1/16 80 Cisco_10.226.197.34 fc1/13 80 Cisco_10.226.197.34 fc1/17 80 Cisco_10.226.197.34 fc1/18 80 Cisco_10.226.197.36 fc1/13 80 Cisco_10.226.197.36 fc1/17 80 Cisco_10.226.197.36 fc1/18 110 Cisco_10.226.197.34 fc1/26 110 Cisco_10.226.197.34 fc1/27 110 Cisco_10.226.197.34 fc1/28 120 Cisco_10.226.197.34 fc1/25 120 Cisco_10.226.197.34 fc1/29 120 Cisco_10.226.197.34 fc1/30 120 Cisco_10.226.197.36 fc1/25 120 Cisco_10.226.197.36 fc1/29 120 Cisco_10.226.197.36 fc1/30 Last Update Time: 7/31/2014 14:45:40 -04:00 Zone Configuration: Member Member Member Zone Name VSAN ID Switch Name Port Name Port ID Member WWN --------- ------- ----------- --------- ------- ---------- dpg_mcc_fcvi 30 Cisco_10.226.197.36 fc1/3 - $default_zone$ 30 Cisco_10.226.197.36 fc1/4 dpg_mcc_storage 40 Cisco_10.226.197.36 fc1/1 $default_zone$ 40 Cisco_10.226.197.36 fc1/5 dpg_mcc_14_fcvi 70 Cisco_10.226.197.36 fc1/15 $default_zone$ 70 Cisco_10.226.197.36 fc1/16 dpg_mcc_14_storage 80 Cisco_10.226.197.34 fc1/13 $default_zone$ 80 Cisco_10.226.197.34 fc1/17 dpg_mcc_15_fcvi 110 Cisco_10.226.197.36 fc1/27 $default_zone$ 110 Cisco_10.226.197.36 fc1/28 dpg_mcc_15_storage 120 Cisco_10.226.197.34 fc1/25 $default_zone$ 120 Cisco_10.226.197.34 fc1/29
The following command displays port SFP information about all storage switches:
cluster::> storage switch show -sfp Switch Name: Cisco_10.226.197.34 Switch WWN: 2000547fee78f088 Fabric WWN: 2001547fee78efb1 Vendor: Cisco Model: DS-C9148-16P-K9 Errors: - Last Update Time: 7/31/2014 14:41:49 -04:00 SFP: Port Name Type Tx Type Vendor Part Number Serial Number --------- ------------- ---------------- ----------- ----------- ------------- fc1/1 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629J9 fc1/2 unknown unknown fc1/3 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629H3 fc1/4 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629QH fc1/5 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160628EA fc1/6 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629QT fc1/7 unknown unknown fc1/8 unknown unknown fc1/9 unknown unknown fc1/10 unknown unknown fc1/11 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629GP fc1/12 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS16061X71 fc1/13 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629P8 fc1/14 unknown unknown fc1/15 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629JP fc1/16 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160628D2 fc1/17 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629NG fc1/18 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629R1 fc1/19 unknown unknown fc1/20 unknown unknown fc1/21 unknown unknown fc1/22 unknown unknown fc1/23 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629NC fc1/24 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160628CX fc1/25 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629NZ fc1/26 unknown unknown fc1/27 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS16061XB0 fc1/28 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS16061XA6 fc1/29 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS16061XA0 fc1/30 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS16061X9S fc1/31 unknown unknown fc1/32 unknown unknown fc1/33 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS16061NL7 fc1/34 unknown unknown fc1/35 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629M8 fc1/36 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629KH fc1/37 unknown unknown fc1/38 unknown unknown fc1/39 unknown unknown fc1/40 unknown unknown fc1/41 unknown unknown fc1/42 unknown unknown fc1/43 unknown unknown fc1/44 unknown unknown fc1/45 unknown unknown fc1/46 unknown unknown fc1/47 unknown unknown fc1/48 unknown unknown port-channel 1 unknown unknown port-channel 2 unknown unknown port-channel 3 unknown unknown port-channel 4 unknown unknown port-channel 5 unknown unknown port-channel 6 unknown unknown port-channel 7 unknown unknown port-channel 8 unknown unknown port-channel 9 unknown unknown port-channel 10 unknown unknown port-channel 11 unknown unknown port-channel 12 unknown unknown sup-fc0
The following command displays port statistics information about all storage switches:
cluster::> storage switch show -stats Switch Name: Cisco_10.226.197.34 Switch WWN: 2000547fee78f088 Fabric WWN: 2001547fee78efb1 Vendor: Cisco Model: DS-C9148-16P-K9 Errors: - Last Update Time: 7/31/2014 14:41:49 -04:00 Port Statistics: Rx Rx Tx Tx Error Port Name Frames Octets Frames Octets Frames ------------ ------------ ------------ ------------ ------------ ------------ fc1/1 2116207233 3710682580 3906335374 859905888 0 fc1/2 1 208 1 208 0 fc1/3 3238899002 903116292 3079548736 4014304952 0 fc1/4 1888758418 1643379900 2434821325 2997002344 0 fc1/5 3719731908 1808138824 1878240211 3421335100 0 fc1/6 2644430347 1042009564 249190625 2003353056 0 fc1/7 1 228 1 228 0 fc1/8 1 156 1 156 0 fc1/9 1 148 1 148 0 fc1/10 1 224 1 224 0 fc1/11 3617142898 4129927136 39089396 2595464620 0 fc1/12 473603889 1560909460 2797562521 2833496016 0 fc1/13 1852255936 1091902804 180309704 1769859928 0 fc1/14 1 140 1 140 0 fc1/15 4997082 3519688264 4283938 3370856432 0 fc1/16 4995287 3519577592 4282173 3370732136 0 fc1/17 55146756 178045212 1733567096 3030415436 0 fc1/18 63005788 4287094736 1726651844 2640371212 0 fc1/19 1 200 1 200 0 fc1/20 1 104 1 104 0 fc1/21 1 108 1 108 0 fc1/22 1 108 1 108 0 fc1/23 1 164 1 164 0 fc1/24 1 216 1 216 0 fc1/25 2810698819 1611009260 471527156 1900246656 0 fc1/26 1 104 1 104 0 fc1/27 4165019838 887421780 3848122102 2581891136 0 fc1/28 58607737 1015197080 101621078 3482734024 0 fc1/29 4266270960 222242144 3766674764 2400640552 0 fc1/30 3984658378 1443835508 152597387 678837848 0 fc1/31 1 220 1 220 0 fc1/32 1 120 1 120 0 fc1/33 1 132 1 132 0 fc1/34 1 144 1 144 0 fc1/35 1 160 1 160 0 fc1/36 1 104 1 104 0 fc1/37 1 148 1 148 0 fc1/38 1 184 1 184 0 fc1/39 1 160 1 160 0 fc1/40 1 136 1 136 0 fc1/41 1 196 1 196 0 fc1/42 1 128 1 128 0 fc1/43 1 168 1 168 0 fc1/44 1 212 1 212 0 fc1/45 1 136 1 136 0 fc1/46 1 224 1 224 0 fc1/47 1 104 1 104 0 fc1/48 1 104 1 104 0