Display storage shelf ports
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The storage shelf port show
command displays information for storage shelf ports in the storage system. If no parameters are specified, the default command displays the following information for the ports:
-
Shelf Name
-
ID
-
Module
-
State
-
Internal?
To display detailed information for a single port, use the -shelf
and -id
parameters.
Parameters
- {
[-fields <fieldname>,…]
-
Displays output in column style about the specified fields for all shelf ports.
- |
[-cables ]
-
Displays information about all cables connected to the shelf ports.
- |
[-instance ]
-
Displays expanded information for all shelf ports in the system. If a shelf and ID are specified, then this parameter displays the same detailed information for the specified port as does the -shelf and -id parameters.
[-shelf <text>]
- Shelf Name-
Displays the ports in the storage shelf that matches the specified shelf name.
[-id <integer>]
- Port ID-
Displays the ports that match the specified ID.
[-node {<nodename>|local}]
- Node Name-
Displays the ports that are present for the specified node.
[-module-id {A|B}]
- Module ID-
Displays the ports from the specified shelf module ID.
[-is-internal {true|false}]
- Is Port Internal?-
Displays the ports that are internal.
[-location <text>]
- Location-
Displays the ports with the specified location.
[-is-cable-connected {true|false}]
- Is Cable Connected?-
Displays the ports that have cables connected to them.
[-is-error {true|false}]
- Any Errors?-
Displays the ports for which errors have been logged.
[-connector-state {connected|disconnected|error}]
- Connector State-
Displays the ports with the specified connector state.
[-connector-serial-number <text>]
- Connector Serial Number-
Displays the ports with the specified connector serial number.
[-connector-type {QSFP|QSFP+|QSFP28|Mini-SAS-HD}]
- Connector Type-
Displays the ports with the specified connector type.
[-cable-vendor <text>]
- Cable Vendor-
Displays the ports that are connected to a cable from the specified vendor.
[-cable-part-number <text>]
- Cable Part Number-
Displays the ports that are connected to a cable with the specified part number.
[-cable-technology {active-copper|passive-copper|optical}]
- Cable Technology-
Displays the ports that are connected to a cable with the specified technology.
[-cable-length <text>]
- Cable Length-
Displays the ports that are connected to a cable with the specified length.
[-cable-id <text>]
- Cable ID-
Displays the ports that are connected to a cable with the specified ID.
[-cable-end {end_0|end_1}]
- Cable End-
Displays the ports that are connected to a cable with the specified cable end.
[-designator <text>]
- Designator-
Displays the ports with the specified designator.
[-wwn <text>]
- Local Device WWN-
Displays the ports with the specified WWN.
[-remote-wwn <text>]
- Remote Device WWN-
Displays the ports connected to the specified remote WWN.
[-remote-phy <text>]
- Remote Phy-
Displays the ports connected to the specified remote PHY.
[-swap-count <integer>]
- Swap Count-
Displays the ports with the specified swap count.
[-mac <MAC Address>]
- Local MAC Address-
Displays the ports with the specified MAC address.
[-remote-mac <MAC Address>]
- Remote MAC Address-
Displays the ports connected to the specified MAC address.
[-remote-port <text>]
- Remote Port-
Displays the ports connected to the specified port.
[-remote-chassis <text>]
- Remote Chassis-
Displays the ports connected to the specified chassis.
[-remote-device <text>]
- Remote Device-
Displays the ports connected to the specified device.
[-vlan-id <integer>]
- VLAN ID-
Displays the ports with the specified VLAN ID.
Examples
The following example displays information about all shelf ports:
cluster1::> storage shelf port show Shelf ID Module State Internal? ----- -- ------ ------------ --------- 1.4 0 A connected false 1 A connected false 2 B connected false 3 B connected false 4 entries were displayed.
The following example displays expanded information about port 0 in shelf 1.4:
cluster1::> storage shelf port show -shelf 1.4 -id 0 Shelf Name: 1.4 Port ID: 0 Module ID: A Is Port Internal?: false Location: rear of the shelf at the top left, on shelf module A Is Cable Connected?: true Any Errors?: false Connector State: connected Connector Serial Number: 616930439 Connector Type: qsfp+ Cable Vendor: Molex Inc. Cable Part Number: 112-00431+A0 Cable Technology: passive-copper Cable Length: 5m Cable ID: 500a0980000b6c3f-50000d1703544b80 Cable End: end_1 Designator: sqr Local Device WWN: 500A0980000B6C3F Remote Device WWN: 50000D1703544B80 Remote Phy: 12 Swap Count: 0
The following example displays information about the cables:
cluster1::> storage shelf port show -cables Shelf: 1.4 ID Vendor Part Number Technology Length Type Serial Number -- ---------- ------------- -------------- -------- ----------- -------------- 0 Molex Inc. 112-00431+A0 passive-copper 5m qsfp+ 616930439 1 Molex Inc. 112-00431+A0 passive-copper 5m qsfp+ 616930364 2 Molex Inc. 112-00431+A0 passive-copper 5m qsfp+ 616930452 3 Molex Inc. 112-00431+A0 passive-copper 5m qsfp+ 616930474 4 entries were displayed.