A newer release of this product is available.
        
        
      storage port reset-device
Reset a device behind a storage port
Availability: This command is available to cluster administrators at the advanced privilege level.
Description
The `storage port reset-device` command resets a device behind a port. If the device is behind a SAS port, you need to specify the shelf name and bay ID where the device resides. If the device is behind a FC port, you need to specify the loop ID of the device. This command is not supported on Ethernet storage ports (type = ENET).
Parameters
- -node {<nodename>|local}- Node (privilege: advanced)
- 
Use this parameter to specify the node on which the port resides. 
- -port <text>- Port (privilege: advanced)
- 
Use this parameter to specify the port used to reset the device. 
- { -shelf-name <text>- Shelf Name (privilege: advanced)
- 
Use this parameter to specify the shelf where the device resides. 
- -bay-id <integer>- Bay ID (privilege: advanced)
- 
Use this parameter to specify the bay where the device resides. 
- | -loop-id <integer>- Loop ID (privilege: advanced) }
- 
Use this parameter to specify the loop ID of the device. 
Examples
The following example resets a device behind SAS port 0a on node node1:
cluster1::> storage port reset-device -node node1 -port 0a -shelf-name 1.0 -bay-id 10
The following example resets a device behind FC port 1b on node node1:
cluster1::> storage port reset-device -node node1 -port 1b -loop-id 20