system controller flash-cache show
- PDF of this doc site
Collection of separate PDF docs
Creating your file...
Display the Flash Cache device status
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The system controller flash-cache show
command displays the current Flash Cache device information.
Parameters
- {
[-fields <fieldname>,…]
-
If you specify the
-fields <fieldname>, …
parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify. - |
[-instance ]
} -
If you specify the
-instance
parameter, the command displays detailed information about all fields. [-node {<nodename>|local}]
- Node-
If this parameter is specified, only status information for the matching node is displayed.
[-slot <integer>]
- Slot-
If this parameter is specified, only status information for the matching slot is displayed.
[-subslot <integer>]
- Subslot-
If this parameter is specified, only status information for the matching subslot is displayed.
[-domain <integer>]
- Domain-
If this parameter is specified, only status information for the matching PCI domain is displayed.
[-bus <integer>]
- Bus-
If this parameter is specified, only status information for the matching PCI bus is displayed.
[-slot-string <text>]
- Slot String-
If this parameter is specified, only status information for the matching slot is displayed. Format can be slot or slot-subslot.
[-device-state {ok|erasing|erased|failed|removed|online|offline_failed|degraded|offline_threshold}]
- Device State-
If this parameter is specified, only status information for the matching device-state is displayed.
[-model-number <text>]
- Model Number-
If this parameter is specified, only status information for the matching model-number is displayed.
[-part-number <text>]
- Part Number-
If this parameter is specified, only status information for the matching part-number is displayed.
[-serial-number <text>]
- Serial Number-
If this parameter is specified, only status information for the matching serial-number is displayed.
[-firmware-version <text>]
- Firmware Version-
If this parameter is specified, only status information for the matching firmware-version is displayed.
[-firmware-file <text>]
- Firmware Filename-
If this parameter is specified, firmware-file is the base name of the firmware file located in disk_fw to update the device firmware.
[-hardware-revision <text>]
- Hardware Revision-
If this parameter is specified, only status information for the matching hardware-revision is displayed.
[-capacity <integer>]
- Capacity-
If this parameter is specified, only status information for the matching capacity is displayed.
[-last-change-time <integer>]
- Time Last State Change-
If this parameter is specified, only status information for the matching last-change-time is displayed.
[-service-time <integer>]
- Service Time-
If this parameter is specified, only status information for the matching service-time is displayed.
[-percent-online <integer>]
- Percent Online-
If this parameter is specified, only status information for the matching percent-online is displayed.
[-average-erase-cycle-count <integer>]
- Avg Erase Cycle Count-
If this parameter is specified, only status information for the matching average-erase-cycle-count is displayed.
[-threshold-profile <text>]
- Threshold Profile-
If this parameter is specified, only status information for the matching threshold-profile is displayed.
Examples
The following example displays the current state of all Flash Cache devices:
cluster1::> system controller flash-cache show Model Part Serial Firmware Capacity Device Node Slot Number Number Number Version (GB) State ---------- ---- ------ --------- -------------------- -------- -------- ------ node1 6-1 X9172A 119-00209 A22P7061550000004 NA00 4096 ok 6-2 X9170A 119-00207 A22P5061550000135 NA00 1024 ok node2 6-1 X9172A 119-00209 A22P7061550000007 NA00 4096 ok 6-2 X9170A 119-00207 A22P5061550000091 NA00 1024 ok 4 entries were displayed.