system controller pci show
- PDF of this doc site
Collection of separate PDF docs
Creating your file...
Display the PCI Device Table
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The system controller pci show
command displays details of the PCI devices present in all of the nodes in a cluster. These commands are available for 80xx, 25xx and later systems. Earlier models are not supported. By default, the command displays the following information about the PCI devices:
-
Node name
-
Display name
-
Correctable error count
-
Functional link width
-
Functional link speed
-
Health monitor status
To display more details, use the -instance parameter.
Parameters
- {
[-fields <fieldname>,…]
-
Selects the fields that you specify.
- |
[-instance ]
} -
Displays detailed information for all of the PCI devices.
[-node {<nodename>|local}]
- Node-
Selects the PCI devices that are present in the specified node.
[-bus-number <integer>]
- Bus Number-
Selects the PCI devices with the specified bus number.
[-device-number <integer>]
- Device Number-
Selects the PCI devices with the specified device number.
[-function-number <integer>]
- Function Number-
Selects the PCI devices with the specified function number.
[-slot-number <integer>]
- Slot Info-
Selects the PCI devices with the specified slot number.
[-monitor {node-connect|system-connect|system|controller|chassis|cluster-switch|example}]
- Health Monitor Name-
Selects the PCI devices monitored by the specified health monitor.
[-vendor-id <Hex Integer>]
- Vendor ID-
Selects the PCI devices with the specified vendor ID.
[-device-id <Hex Integer>]
- Device ID-
Selects the PCI devices with the specified device ID.
[-physical-link-width <integer>]
- Physical Link Width-
Selects the PCI devices with the specified physical link width.
[-functional-link-width <integer>]
- Functional Link Width-
Selects the PCI devices with the specified functional link width.
[-physical-link-speed <text>]
- Physical Link Speed(GT/s)-
Selects the PCI devices with the specified physical link speed.
[-functional-link-speed <text>]
- Functional Link Speed(GT/s)-
Selects the PCI devices with the specified functional link speed.
[-unique-name <text>]
- Unique Name-
Selects the PCI devices with the specified unique name.
[-corr-err-count <integer>]
- Correctable Error Count-
Selects the PCI devices with the specified correctable error count.
[-health {ok|ok-with-suppressed|degraded|unreachable|unknown}]
- Status-
Selects the PCI devices with the specified health monitor status.
[-display-name <text>]
- Display Name-
Selects the PCI devices with the specified display name.
[-cerr-diff <integer>]
- Correctable Error Difference-
Selects the PCI devices with the specified difference in correctable error count.
Examples
The example below displays the information about the PCIe devices present in all of the nodes in the cluster.
cluster1::> system controller pci show Display Correctable Functional Functional Node Name Error Count Link Width Link Speed Status ------------- ------------------------ ----------- ---------- ---------- ------ cluster1-01 Ontap PCI Device 0 0 4 5GT/s ok cluster1-02 Ontap PCI Device 4 0 4 5GT/s ok
The example below displays detailed information about a PCIe device in a node.
cluster1::> system controller pcie show -instance -node cluster1-01 -bus-number 1 Node: cluster1-01 Bus Number: 1 Device Number: 0 Function Number: 0 Slot Info: 0 Health Monitor Name: controller Vendor ID: 11f8 Device ID: 8001 Physical Link Width: 4 Functional Link Width: 4 Physical Link Speed(GT/s): 5GT/s Functional Link Speed(GT/s): 5GT/s Unique Name: ontap0@pci0:1:0:0 Correctable Error Count: 0 Status: ok Display Name: Ontap PCI Device 0 Correctable Error Difference: 0