vserver check lif-multitenancy run
- PDF of this doc site
Collection of separate PDF docs
Creating your file...
Run check for LIF multitenancy
Availability: This command is available to cluster and Vserver administrators at the admin privilege level.
Description
The run command checks the specified Vserver to verify that it has connectivity to the configured external servers providing services such as Active Directory, NIS, and DNS. The output can consist of three types of messages. Failure messages indicate that a Vserver does not have the connectivity required to a server exporting a service. Warning messages indicate configuration or operational issues that are possible causes of the failures. A success message is displayed if the Vserver has network connectivity to each of the configured servers for each service.
You can use this command to verify configuration changes such as creating a Vserver or changing the configured servers for one or more services. It is also useful for diagnosing operational problems that result from failures that could be caused by the inability to make network connections to configured servers.
The services that are checked are DNS, NIS, CIFS preferred domain controllers, CIFS discovered domain controllers, KDC, Active Directory, Admin, Password, LDAP, and LDAP preferred Active Directory.
Only a single run for a Vserver is allowed to run in a cluster. If multiple runs are attempted for a Vserver, a message will be displayed indicating that a run is already in progress.
For each service, this command will ping each configured server until a successful ping is completed. In certain circumstances where a subnet is offline or LIFs are operationally down, this command may take a long time to run. In order to show that forward progress is being made, an activity indicator of a '.' is displayed for each ping sent.
The following fields are reported in table format. Some fields may not be relevant to a type of message and will consist of the text "-".
-
Vserver name
-
Service external server is exporting
-
Address of external server
-
Connectivity to that external server
-
More information describing the problem
-
Suggestions to remediate the problems
-
Success when there are no problems
Parameters
-vserver <vserver>
- Vserver-
Use this parameter to specify the Vserver to check.
[-verbose {true|false}]
- Show Positive and Negative Result (privilege: advanced)-
When this parameter is specified the results of all connectivity tests will be displayed in the success and failure cases.
Examples
This is an example of a successful run:
cluster1::> vserver check lif-multitenancy run -vserver vs0 .. SUCCESS: All external servers are reachable.
This is an example of a run with warnings and failures that need to be corrected:
cluster1::> vserver check lif-multitenancy run -vserver vs0 Vserver Severity Service Address LIF Connected Details --------------- -------- ------------------ --------------- --------------- ---------- --------------- vs0 warning - - vs0_lif1 - operationally down vs0 warning - - vs0_lif2 - operationally down ... vs0 failure DNS 10.98.200.20 - no cache ... vs0 failure NIS domain 10.98.13.53 - no cache Error : command failed: FAILURES FOUND. You must correct these failures to avoid service disruptions in DOT 8.3 and above. Corrective actions may include: - removing decommissioned external servers from the vserver configuration - restoring network interfaces that are down - adding network interfaces or routes - modifying the locations where network interfaces may reside (through adjusting failover groups/policies or changing the home-node or auto-revert settings). For assistance, please consult the 8.3 Upgrade Document, or contact support personnel.
At advanced privilege, additional information for messages at all severities is displayed.
cluster1::*> vserver check lif-multitenancy run -vserver vs0 -verbose true .... Vserver Severity Service Address LIF Connected Details --------------- -------- ------------------ --------------- --------------- ---------- --------------- vs0 info DNS 10.98.200.20 vs0_lif1 yes ping .... vs0 info NIS domain 10.98.13.53 vs0_lif1 yes ping SUCCESS: All external servers are reachable.