disk.ddr events
disk.ddr.dqp.out.of.date
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when the Dynamic Drive Recognition (DDR) Scanner detects a disk that is not part of its qualification table.
 - Corrective Action
 - 
Check your support provider's web site or knowledgebase for more information about downloading and installing an updated Disk Qualification Package (DQP) file.
 - Syslog Message
 - 
The DDR Scanner has detected that the latest DQP is not present on this system.
 - Parameters
 - 
(None).
 
disk.ddr.invalid.azcs.capacity
- Severity
 - 
ERROR
 - Description
 - 
This event is generated when the DDR Scanner detects a capacity value that does not match with the alias string associated with it.
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
The DDR Scanner has detected an invalid AZCS alias capacity on disk %s
 - Parameters
 - 
diskname (STRING): Name of the disk.
capacity_value (LONGINT): The value of the invalid capacity 
disk.ddr.invalid.bcs.capacity
- Severity
 - 
ERROR
 - Description
 - 
This event is generated when the DDR Scanner detects a capacity value that does not match with the alias string associated with it.
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
The DDR Scanner has detected an invalid BCS alias capacity on disk %s
 - Parameters
 - 
diskname (STRING): Name of the disk.
capacity_value (LONGINT): The value of the invalid capacity 
disk.ddr.scanner.ddr.failure
- Severity
 - 
NOTICE
 - Description
 - 
This event is issued when a the ddr scanner has failed to read the new DDR label it just placed on the disk.
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
Disk %s Shelf %s Bay %s [%s %s %s] S/N [%s] [%s]: DDR label verify Failure - DDR Error
 - Parameters
 - 
disk_name (STRING): The name of the disk
shelf (STRING): Shelf identifier where the disk is located
bay (STRING): Disk bay within the shelf where disk is located
vendor (STRING): Name of the vendor of the disk
model (STRING): Model string of the disk drive
firmware_revision (STRING): Firmware revision of the disk
serialno (STRING): Serial number of the disk
ddr_error (STRING): DDR Error string which has been parsed 
disk.ddr.scanner.label.done
- Severity
 - 
NOTICE
 - Description
 - 
This event is issued when a the ddr scanner has completed has completed scanning a disk successfully
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
Disk %s Shelf %s Bay %s [%s %s %s] S/N [%s] : DDR label write complete
 - Parameters
 - 
disk_name (STRING): The name of the disk
shelf (STRING): Shelf identifier where the disk is located
bay (STRING): Disk bay within the shelf where disk is located
vendor (STRING): Name of the vendor of the disk
model (STRING): Model string of the disk drive
firmware_revision (STRING): Firmware revision of the disk
serialno (STRING): Serial number of the disk 
disk.ddr.scanner.verify.failure
- Severity
 - 
NOTICE
 - Description
 - 
This event is issued when a the ddr scanner has failed to read the new DDR label it just placed on the disk.
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
Disk %s Shelf %s Bay %s [%s %s %s] S/N [%s] : DDR label verify Failure
 - Parameters
 - 
disk_name (STRING): The name of the disk
shelf (STRING): Shelf identifier where the disk is located
bay (STRING): Disk bay within the shelf where disk is located
vendor (STRING): Name of the vendor of the disk
model (STRING): Model string of the disk drive
firmware_revision (STRING): Firmware revision of the disk
serialno (STRING): Serial number of the disk 
disk.ddr.scanner.write.failure
- Severity
 - 
NOTICE
 - Description
 - 
This event is issued when a the ddr scanner has failed to write a new DDR label to the disk
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
Disk %s Shelf %s Bay %s [%s %s %s] S/N [%s] : DDR label write Failure
 - Parameters
 - 
disk_name (STRING): The name of the disk
shelf (STRING): Shelf identifier where the disk is located
bay (STRING): Disk bay within the shelf where disk is located
vendor (STRING): Name of the vendor of the disk
model (STRING): Model string of the disk drive
firmware_revision (STRING): Firmware revision of the disk
serialno (STRING): Serial number of the disk 
disk.ddr.unable.add.disk
- Severity
 - 
ALERT
 - Description
 - 
This event is generated when the DDR Scanner is unable to re-add a disk to the filer after trying for 2 minutes. This means there are no more spare disk_Cbs in the filer.
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
The filer has not freed a disk_Cb for over 2 mintues for %s.
 - Parameters
 - 
diskuid (STRING): The unique identifier of the disk