diskshelf.psu events
Collection of separate PDF docs
Creating your file...
diskShelf.psu.added
- Severity
-
NOTICE
- Description
-
This message occurs when a power supply unit is added to the disk shelf.
- Corrective Action
-
(None).
- Syslog Message
-
%s power supply was added to %s.shelf%d
- Parameters
-
location (STRING): Which power supply was added.
channelName (STRING): Channel connected to disk shelf.
shelfIdent (INT): ID number displayed on the disk shelf OPS panel.
serialNumber (STRING): Serial number of disk shelf.
diskShelf.psu.removed
- Severity
-
ERROR
- Description
-
This message occurs when a power supply unit is removed from the disk shelf.
- Corrective Action
-
Insert a functional power supply unit into the disk shelf.
- Syslog Message
-
%s power supply was removed from %s.shelf%d
- Parameters
-
location (STRING): Which power supply was removed.
channelName (STRING): Channel connected to disk shelf.
shelfIdent (INT): ID number displayed on the disk shelf OPS panel.
serialNumber (STRING): Serial number of disk shelf.