Skip to main content
A newer release of this product is available.

fcvi.link events

Contributors
Suggest changes
Severity

NOTICE

Description

This message occurs when the physical link of the Fibre Channel Virtual Interface (FC-VI) adapter goes down.

Corrective Action
  1. Ensure that the FC-VI link has not been tampered with. 2. Verify that the physical status of the FC-VI adapter is "Up" by using the command "metrocluster interconnect adapter show". 3. If the configuration includes fabric switches, ensure that they are properly cabled and configured.

Syslog Message

(None).

Parameters

alertId (STRING): Alert ID.
alertingResource (STRING): Alerting resource unique name.
alertingResourceName (STRING): Alerting resource name.
possibleEffect (STRING): Possible effect for link transition.
probableCause (STRING): Probable cause of the event.
probableCauseDescription (STRING): Probable cause description of the event.
additionalInfo (STRING): Any additional information for the event.

Severity

NOTICE

Description

This message occurs when the physical link of the Fibre Channel Virtual Interface (FC-VI) adapter comes up.

Corrective Action

(None).

Syslog Message

(None).

Parameters

alertId (STRING): Alert ID.
alertingResource (STRING): Alerting resource unique name.