monitor.sparelabelcheckfailed events
Collection of separate PDF docs
Creating your file...
monitor.spareLabelCheckFailed
- Severity
-
NOTICE
- Description
-
This message occurs when the system detects that a hot spare disk has an invalid or a missing label. The system corrects the situation by rewriting the label.
- Corrective Action
-
No user action is required.
- Syslog Message
-
Periodic check of hot spare %s has failed. The system will correct the problem.
- Parameters
-
disk_info (STRING): Formatted information of the disk object.
label_block_num (INT): Label block number code.
label_state (INT): Label state code.
label_read_error (INT): Label read error code.
shelf (STRING): Disk shelf identifier where the disk is located.
bay (STRING): Disk bay within the disk shelf where the disk is located.
vendor (STRING): Name of the vendor of the disk.
model (STRING): Model string of the disk.
firmware_revision (STRING): Firmware revision number of the disk.
serialno (STRING): Serial number of the disk.
disk_type (INT): Type of disk.
disk_rpm (STRING): Rotational speed of the disk in RPM.