san.mccvserverinitpending events
san.MCCVserverInitPending
- Severity
 - 
ALERT
 - Description
 - 
This message occurs in MetroCluster™ configurations on clustered Data ONTAP® systems when SAN Vservers exceed the time allotted for initialization during a switchover or switchback operation. This is not a failure, but a delay in initialization.
 - Corrective Action
 - 
Contact NetApp technical support for assistance in analyzing the reason for delay in Vserver initialization.
 - Syslog Message
 - 
The following Vservers: %s exceeded the time allotted (%u seconds) for Vserver initialization. Contact NetApp technical support to analyze the reason for delay in Vserver initialization.
 - Parameters
 - 
pending_vservers (STRING): List of the SAN Vservers pending Vserver initialization.
san_budget_in_msecs (INT): Maximum time (in seconds) the system waits for the SAN Vservers to complete initialization during a switchover or switchback operation.