fg.convert events
fg.convert.critical.fail
- Severity
 - 
ALERT
 - Description
 - 
This message occurs when the conversion of a FlexVol® volume into a FlexGroup fails. The FlexVol volume is inoperable, and can no longer serve data.
 - Corrective Action
 - 
(Call support).
 - Syslog Message
 - 
Conversion of FlexVol volume %s to FlexGroup with MSID %llu failed. Reason: %s.The FlexVol can no longer serve data. Reason: %s.
 - Parameters
 - 
volumeName (STRING): Name of the volume being converted to a FlexGroup.
flexgroupMsid (LONGINTHEX): MSID of the new FlexGroup.
reason (STRING): Reason the conversion failed.
rollbackFailedReason (STRING): Reason the conversion could not roll back after failing to convert. 
fg.convert.fail
- Severity
 - 
ERROR
 - Description
 - 
This message occurs when the conversion of a FlexVol® volume into a FlexGroup fails. The FlexVol volume is still operable.
 - Corrective Action
 - 
Ensure that the FlexVol volume is a valid candidate for the convert operation, and then retry the command. If the error persists, contact NetApp technical support.
 - Syslog Message
 - 
Conversion of FlexVol volume %s to FlexGroup with MSID %llu failed. Reason: %s
 - Parameters
 - 
volumeName (STRING): Name of volume being converted to a FlexGroup.
flexgroupMsid (LONGINTHEX): MSID of the new FlexGroup.
reason (STRING): Reason why the conversion failed. 
fg.convert.ksmf.timeout
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when the operation to convert a FlexVol® volume into a FlexGroup times out when updating the volume's RAID label. The system retries the conversion automatically.
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
Conversion of FlexVol volume %s to FlexGroup with MSID %llu has timed out while updating the volume's RAID label.
 - Parameters
 - 
volumeName (STRING): Name of the volume being converted to a FlexGroup.
flexgroupMsid (LONGINTHEX): MSID of the new FlexGroup. 
fg.convert.start
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when the conversion of a FlexVol® volume to a FlexGroup begins.
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
Starting conversion of FlexVol volume %s to new FlexGroup with MSID %llu, UUID %s.
 - Parameters
 - 
volumeName (STRING): Name of volume being converted to a FlexGroup.
flexgroupMsid (LONGINTHEX): MSID of the new FlexGroup.
flexgroupUuid (STRING): UUID of the new FlexGroup. 
fg.convert.success
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when the conversion of a FlexVol® volume into a FlexGroup succeeds.
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
Conversion of FlexVol volume %s to FlexGroup with MSID %llu successful.
 - Parameters
 - 
volumeName (STRING): Name of volume being converted to a FlexGroup.
flexgroupMsid (LONGINTHEX): MSID of the new FlexGroup.