sfu.download events
Collection of separate PDF docs
Creating your file...
sfu.download.details
- Deprecated
-
Deprecated as of ONTAP® version 9.6. A new EMS message is added.
- Severity
-
NOTICE
- Description
-
This message occurs when a disk shelf firmware update completes download firmware to a disk shelf or shelves in the system.
- Corrective Action
-
Shelf firmware update will be attempted again in the next background shelf firmware update.
- Syslog Message
-
%s: Download of firmware file %s on %s.shelf%d might not have completed on one module as %s. An attempt to download again will be done in the next cycle.
- Parameters
-
cmdName (STRING): Name of the command issued, such as "storage shelf firmware update".
fileName (STRING): Name of the file in /etc/shelf_fw that was being downloaded.
channelName (STRING): Name of the adapter port or switch port on which the disk shelf firmware download error occurred.
shelfId (INT): ID of the disk shelf on which the disk shelf firmware download error occurred.
ErrorReason (STRING): More information about the reason for download error.
sfu.download.done.details
- Severity
-
NOTICE
- Description
-
This message occurs when a shelf firmware update finishes downloading firmware to a shelf or shelves in the system.
- Corrective Action
-
Shelf firmware update will be attempted again in the next background shelf firmware update.
- Syslog Message
-
%s: Download of firmware file on %s.shelf%d might not have been completed on one module because %s. An attempt to download again will be done in the next cycle.
- Parameters
-
cmdName (STRING): Name of the command issued, such as "storage shelf firmware update".
channelName (STRING): Name of the adapter port or switch port on which the disk shelf firmware download error occurred.
shelfId (INT): ID of the shelf on which the shelf firmware download error occurred.
ErrorReason (STRING): More information about the reason for download error.