config.cfomixedabmodule events
Collection of separate PDF docs
Creating your file...
config.CFOmixedABmodule
- Severity
-
ALERT
- Description
-
This message occurs when a disk shelf attached to a node is miscabled so that one disk shelf's module A is connected to the next disk shelf's module B, or vice versa.
- Corrective Action
-
Identify the miscabled disk shelf, and then recable it. For FC shelves, ensure that each disk shelf's module A is connected Output to Input to the next disk shelf's module A, and that the disk shelf's module B is connected Output to Input to the next disk shelf's module B. For SAS shelves, connect the port identified with a circle on disk shelf module A to the port identified with a square on the next disk shelf's module A, and the "circle" port on module B to the next disk shelf's "square" port.
- Syslog Message
-
Host adapter %s has miscabled disk shelves; one disk shelf's module A is connected to the next disk shelf's module B, or vice versa.
- Parameters
-
adapter (STRING): Adapter that the miscabled disk shelf is on.