sfu.statuscheckfailure events
sfu.statusCheckFailure
- Severity
-
ERROR
- Description
-
This message occurs when the (advanced privilege) "storage shelf firmware update" command encounters a failure while attempting to read the status of the firmware update in progress.
- Corrective Action
-
Retry the (advanced privilege) "storage shelf firmware update" command.
- Syslog Message
-
%s: failed status check of f/w update on %s.shelf%d [%x] %s, retry_count = %d, %s.
- Parameters
-
cmdName (STRING): Name of the command issued, such as "storage shelf firmware update".
channelName (STRING): Name of the adapter port or switch port on which the disk shelf firmware is to be downloaded.
shelfId (INT): ID of the disk shelf on which the disk shelf firmware is to be downloaded.
outStatusFlags (INTHEX): Output status flags value of the I/O operation (ONTAP® software internal value).
ModuleType (STRING): Module type, such as AT-FCX, AT-FC, ESH, LRC, and so on.
retryCount (INT): Number of times the status read has been retried.
DeviceStatus (STRING): Whether the SES target device status is OK or MISSING.