vsdr.volume events
vsdr.volume.idconflict
- Severity
-
ERROR
- Description
-
This message occurs when the the volume to be created on the destination cluster fails because of an internal identity conflict with another volume in the system.
- Corrective Action
-
Log in to the source cluster and delete the volume by using the "volume delete" command.
- Syslog Message
-
Configuration replication for volume "%s" in Vserver "%s" has failed because of an internal ID conflict.
- Parameters
-
volume_name (STRING): Volume on which this error occurred.
vserver_name (STRING): Vserver name for which configuration replication is happening.
vsdr.volume.name.conflict
- Severity
-
ERROR
- Description
-
This message occurs during a SnapMirror resync® operation on a Storage Virtual Machine (SVM) disaster recvoery (DR) relationship, when a new volume needs to be created on the destination SVM but another volume with the same name already exists on it, and it is also the destination of a volume-level SnapMirror relationship. The resync operation fails to start.
- Corrective Action
-
Rename the volume on the destination SVM by using the "volume rename" command or delete it by using the "volume delete" command, and then execute another "snapmirror resync" command.
- Syslog Message
-
The volume "%s" is already present in SVM "%s" and it is the destination of a volume-level SnapMirror relationship.
- Parameters
-
volume_name (STRING): Name of the volume that the system is trying to replicate into the destination SVM.
vserver_name (STRING): SVM name for which the SnapMirror resync was initiated.
vsdr.volume.sis.on.fail
- Severity
-
ALERT
- Description
-
This message occurs when a Vserver DR subsystem fails to enable volume efficiency on the volume.
- Corrective Action
-
Enable volume efficiency on the destination volume by using the "volume efficiency on" command. For more information, refer to TR-4476.
- Syslog Message
-
Vserver DR: Volume efficiency configuration is not applied on volume %s of Vserver %s. Reason: %s
- Parameters
-
destination_volume (STRING): Name of the destination volume of the Vserver DR relationship.
destination_vserver (STRING): Name of the destination Vserver of the Vserver DR relationship.
reason (STRING): Reason.