diskown.drawer events
diskown.drawer.assignStatus
- Severity
-
NOTICE
- Description
-
This message occurs when drawer-based drive assignment for shelves with drawers is enabled or disabled.
- Corrective Action
-
(None).
- Syslog Message
-
Drawer-based automatic drive assignment for shelf "%d" is "%s".
- Parameters
-
shelf_id (INT): Shelf identifier.
state (STRING): Drawer-based automatic drive assignment state..
diskown.drawer.invalidShlf
- Severity
-
ERROR
- Description
-
This message occurs when the controller cannot automatically assign disks because the shelf is either offline, or temporarily unavailable, and therefore cannot be queried for the information that is required to properly assign the disks to the controller. This can also occur when multiple shelves in a cluster have the same shelf ID. Automatic disk assignment fails for the disks in this shelf until the shelf is back online or any shelf ID conflicts within a cluster are resolved.
- Corrective Action
-
Use the "storage shelf show" command to verify that the specified shelf is online and to verify connectivity from the controller to all of the paths to the shelf. If multiple shelves in a cluster have the same shelf ID, resolve that and ensure that shelves in that cluster have different shelf IDs.
- Syslog Message
-
The system cannot automatically assign disks for shelf "%d" because the shelf is in an invalid state.
- Parameters
-
shelf_id (INT): Shelf identifier.
diskown.drawer.MultiOwners
- Severity
-
ERROR
- Description
-
This message occurs when the system cannot automatically assign disks because some of the disks are assigned to multiple systems in a conflicting manner.
- Corrective Action
-
1) Find all of the disks belonging to the specified shelf by using the "storage disk show" command. 2) View the list of systems by using the "disk show -v" command. 3) Ensure that disks assigned on lower half bays of each drawer are owned by a single owner, and ensure that disks assigned on higher half bays of each drawer are owned by a different single owner. Disks assigned on lower half bays of each drawer must have a different owner than disks assigned on higher half bays.
- Syslog Message
-
The system cannot automatically assign disks because the disks in shelf "%d" are assigned to multiple systems in a conflicting manner.
- Parameters
-
shelf_id (INT): Shelf identifier.