Skip to main content
ONTAP EMS reference

flexcache.auto events

Suggest changes

flexcache.auto.cache.config.cleanup

Severity

ALERT

Description

This message occurs when a FlexCache® configuration is deleted automatically on the FlexCache Origin cluster as the config refresh operation failed due to the FlexCache volume being deleted.

Corrective Action

(None).

Syslog Message

FlexCache configuration corresponding to FlexCache volume %s in Vserver with UUID %s on cluster with UUID %s has been deleted automatically as the config refresh operation failed due to the FlexCache volume being deleted. The FlexCache origin volume %s in Vserver with UUID %s has been cleaned up.

Parameters

cacheVolumeName (STRING): Name of the FlexCache volume.
cacheVserverUuid (STRING): Universal unique identifier (UUID) of the storage virtual machine (SVM) hosting the FlexCache volume.
cacheClusterUuid (STRING): UUID of the cluster hosting the FlexCache volume.
originVolumeName (STRING): Name of the FlexCache origin volume.
originVserverUuid (STRING): Universal unique identifier (UUID) of the storage virtual machine (SVM) hosting the FlexCache origin volume.