mcc.nvmeof events
mcc.nvmeof.port.modify
- Severity
-
NOTICE
- Description
-
This message occurs when the mode of an NVMe-oF port is changed.
- Corrective Action
-
(None).
- Syslog Message
-
Changing NVMe-oF port %s to %s mode.
- Parameters
-
port (STRING): Name of port being configured.
mode (STRING): Mode in which to configure port: network or storage.
mcc.nvmeof.rdma.disconnect.event
- Deprecated
-
Deprecated as of version 9.13.1.
- Severity
-
NOTICE
- Description
-
This message occurs when the NVMe-oF driver detects an RDMA disconnect. There might be a decrease in performance while reconnecting.
- Corrective Action
-
(None).
- Syslog Message
-
NVMe-oF RDMA disconnect on subnqn %s, controller ID %d, qpair ID %d.
- Parameters
-
subnqn (STRING): Subsystem NVMe qualified name.
ctrlr_id (INT): Controller ID.
qpair (INT): Qpair ID.
mcc.nvmeof.rdma.disconnect.status
- Deprecated
-
Deprecated as of version 9.13.1.
- Severity
-
NOTICE
- Description
-
This message occurs when the NVMeoF driver detects a command that finishes with a disconnect status. There might be a decrease in performance while reconnecting.
- Corrective Action
-
(None).
- Syslog Message
-
NVMe-oF disconnect on subnqn %s, controller ID %d, qpair ID %d.
- Parameters
-
subnqn (STRING): Subsystem NVMe qualified name.
ctrlr_id (INT): Controller ID.
qpair (INT): Qpair ID.
mcc.nvmeof.subsystem.add
- Severity
-
NOTICE
- Description
-
This message occurs when an NVMe-oF subsystem is added.
- Corrective Action
-
(None).
- Syslog Message
-
NVMe-oF subsystem added at address %s.
- Parameters
-
address (STRING): IP address of susbsystem.
mcc.nvmeof.subsystem.delete
- Severity
-
NOTICE
- Description
-
This message occurs when an NVMe-oF subsystem is deleted.
- Corrective Action
-
(None).
- Syslog Message
-
NVMe-oF subsystem deleted at address %s.
- Parameters
-
address (STRING): IP address of susbsystem.
mcc.nvmeof.timeout
- Severity
-
NOTICE
- Description
-
This message occurs when the NVMeoF driver detects a timeout on a request. There might be a decrease in performance while retrying.
- Corrective Action
-
(None).
- Syslog Message
-
Timeout on subnqn %s, controller ID %d, qpair ID %d, sequence number %d.
- Parameters
-
subnqn (STRING): Subsytem NVMe qualified name.
ctrlr_id (INT): Controller ID.
qpair (INT): Qpair ID.
cid (INT): NVMe-oF CID.