Reenabling the switch fabric and verifying the operation
-
PDF of this doc site
-
Install a fabric-attached MetroCluster
-
Cable a fabric-attached MetroCluster configuration
-
Plan and install a MetroCluster configuration with array LUNs
-
-
Install a MetroCluster IP configuration
-
Install a stretch MetroCluster configuration
-
Maintain the MetroCluster components
-
Transition from MetroCluster FC to MetroCluster IP
-
Upgrade, refresh, or expand the MetroCluster configuration
-

Collection of separate PDF docs
Creating your file...
You must enable the FC switch fabric and ensure that the switches and devices are operating correctly.
-
Enable the switches:
switchCfgPersistentEnable
If this command is not available, the switch should be in the enabled state after the
fastBoot
command is issued.-
The following example shows the command issued on FC_switch_A_1:
FC_switch_A_1:admin> switchCfgPersistentEnable
-
The following example shows the command issued on FC_switch_B_1:
FC_switch_B_1:admin> switchCfgPersistentEnable
-
-
Verify that the switches are online and all devices are properly logged in:
switchShow
The following example shows the command issued on FC_switch_A_1:
FC_switch_A_1:admin> switchShow
The following example shows the command issued on FC_switch_B_1:
FC_switch_B_1:admin> switchShow
-
Run the fmc_dc utility to ensure that the 7-Mode fabric MetroCluster is functioning correctly.
You can ignore errors related to Traffic Isolation (TI) zoning and trunking.
-
Repeat the tasks for the second switch fabric.