Contributors netapp-pcarriga netapp-thomi netapp-aherbin

The FibreBridge 7600N bridge is supported on ONTAP 9.5 and later as a replacement for the FibreBridge 7500N or 6500N bridge or when adding new storage to the MetroCluster configuration. The zoning requirements and restrictions regarding use of the bridge's FC ports are the same as that of the FibreBridge 7500N bridge.

Note FibreBridge 6500N bridges are not supported in configurations running ONTAP 9.8 and later.

Use case

Zoning changes needed?

Restrictions

Procedure

Replacing a single FibreBridge 7500N bridge with a single FibreBridge 7600N bridge

No

The FibreBridge 7600N bridge must be configured exactly the same as the FibreBridge 7500N bridge.

Replacing a single FibreBridge 6500N bridge with a single FibreBridge 7600N bridge

No

The FibreBridge 7600N bridge must be configured exactly the same as the FibreBridge 6500N bridge.

Adding new storage through adding a new pair of FibreBridge 7600N bridges

Yes

You must add storage zones for each of the FC ports of the new bridges.

You must have available ports on the FC switch fabric (in a fabric-attached MetroCluster configuration) or on the storage controllers (in a stretch MetroCluster configuration).Each pair of FibreBridge 7500N or 7600N bridges can support up to four stacks.