Retrieve node information
GET /cluster/nodes/{uuid}
Retrieves information for the node.
Related ONTAP commands
-
cluster add-node-status
-
cluster date show
-
cluster ha show
-
network interface show
-
network port show
-
storage failover show
-
system controller show
-
system node show
-
system node show-discovered
-
system service-processor network show
-
system service-processor show
-
version
Learn more
Parameters
Name | Type | In | Required | Description |
---|---|---|---|---|
uuid |
string |
path |
True |
|
fields |
array[string] |
query |
False |
Specify the fields to return. |
Response
Status: 200, Ok
Name | Type | Description |
---|---|---|
_links |
||
cluster_interface |
The cluster network IP address of the node to be added. |
|
cluster_interfaces |
array[cluster_interfaces] |
|
controller |
Controller information |
|
date |
string |
The current or "wall clock" time of the node in ISO-8601 date, time, and time zone format. The ISO-8601 date and time are localized based on the ONTAP cluster's timezone setting.
|
ha |
||
location |
string |
|
management_interface |
The management interface of the node to be added. The subnet mask is set based on the management interface of the cluster or the managment interfaces of other nodes. |
|
management_interfaces |
array[management_interfaces] |
|
membership |
string |
Possible values:
|
model |
string |
|
name |
string |
|
serial_number |
string |
|
service_processor |
||
state |
string |
State of the node:
|
system_id |
string |
|
system_machine_type |
string |
OEM system machine type. |
uptime |
integer |
The total time, in seconds, that the node has been up. |
uuid |
string |
|
vendor_serial_number |
string |
OEM vendor serial number. |
version |
This returns the cluster version information. When the cluster has more than one node, the cluster version is equivalent to the lowest of generation, major, and minor versions on all nodes. |
|
vm |
Example response
{
"_links": {
"self": {
"href": "/api/resourcelink"
}
},
"cluster_interface": {
"ip": {
"address": "10.10.10.7"
}
},
"cluster_interfaces": [
{
"_links": {
"self": {
"href": "/api/resourcelink"
}
},
"ip": {
"address": "10.10.10.7"
},
"name": "lif1",
"uuid": "1cd8a442-86d1-11e0-ae1c-123478563412"
}
],
"controller": {
"flash_cache": [
{
"capacity": 1024000000000,
"firmware_version": "NA05",
"hardware_revision": "A1",
"model": "X1970A",
"part_number": "119-00207",
"serial_number": "A22P5061550000187",
"slot": "6-1",
"state": "string"
}
],
"frus": [
{
"id": 0,
"state": "string",
"type": "string"
}
],
"over_temperature": "string"
},
"date": "2019-04-17 11:49:26 -0400",
"ha": {
"giveback": {
"failure": {
"code": 852126,
"message": "Failed to initiate giveback. Run the \"storage failover show-giveback\" command for more information."
},
"state": "failed"
},
"partners": [
{
"_links": {
"self": {
"href": "/api/resourcelink"
}
},
"name": "node1",
"uuid": "1cd8a442-86d1-11e0-ae1c-123478563412"
}
],
"ports": [
{
"number": 0,
"state": "active"
}
],
"takeover": {
"failure": {
"code": 852130,
"message": "Failed to initiate takeover. Run the \"storage failover show-takeover\" command for more information."
},
"state": "failed"
}
},
"location": "rack 2 row 5",
"management_interface": {
"ip": {
"address": "10.10.10.7"
}
},
"management_interfaces": [
{
"_links": {
"self": {
"href": "/api/resourcelink"
}
},
"ip": {
"address": "10.10.10.7"
},
"name": "lif1",
"uuid": "1cd8a442-86d1-11e0-ae1c-123478563412"
}
],
"membership": "string",
"model": "FAS3070",
"name": "node-01",
"serial_number": "4048820-60-9",
"service_processor": {
"firmware_version": "string",
"ipv4_interface": {
"address": "10.10.10.7",
"gateway": "10.1.1.1",
"netmask": "24"
},
"ipv6_interface": {
"address": "fd20:8b1e:b255:5011:10:141:4:97",
"gateway": "fd20:8b1e:b255:5011:10::1",
"netmask": 64
},
"link_status": "string",
"mac_address": "string",
"state": "string"
},
"state": "string",
"system_id": 92027651,
"system_machine_type": "7Y56-CTOWW1",
"uptime": 300536,
"uuid": "4ea7a442-86d1-11e0-ae1c-123478563412",
"vendor_serial_number": 791603000068,
"version": {
"full": "NetApp Release 9.4.0: Sun Nov 05 18:20:57 UTC 2017",
"generation": 9,
"major": 4,
"minor": 0
},
"vm": {
"provider_type": "string"
}
}
Error
Status: Default, Error
Name | Type | Description |
---|---|---|
error |
Example error
{
"error": {
"arguments": [
{
"code": "string",
"message": "string"
}
],
"code": "4",
"message": "entry doesn't exist",
"target": "uuid"
}
}
Definitions
See Definitions
href
Name | Type | Description |
---|---|---|
href |
string |
_links
Name | Type | Description |
---|---|---|
self |
node_setup_ip
The IP configuration for cluster setup.
Name | Type | Description |
---|---|---|
address |
string |
IPv4 or IPv6 address |
cluster_interface
The cluster network IP address of the node to be added.
Name | Type | Description |
---|---|---|
ip |
The IP configuration for cluster setup. |
ip
IP information
Name | Type | Description |
---|---|---|
address |
string |
IPv4 or IPv6 address |
cluster_interfaces
Network interface
Name | Type | Description |
---|---|---|
_links |
||
ip |
IP information |
|
name |
string |
The name of the interface. |
uuid |
string |
The UUID that uniquely identifies the interface. |
flash_cache
Name | Type | Description |
---|---|---|
capacity |
integer |
Size in bytes |
firmware_version |
string |
|
hardware_revision |
string |
|
model |
string |
|
part_number |
string |
|
serial_number |
string |
|
slot |
string |
|
state |
string |
frus
Name | Type | Description |
---|---|---|
id |
integer |
|
state |
string |
|
type |
string |
controller
Controller information
Name | Type | Description |
---|---|---|
flash_cache |
array[flash_cache] |
A list of Flash-Cache devices. Only returned when requested by name. |
frus |
array[frus] |
List of FRUs on the node. Only returned when requested by name. |
over_temperature |
string |
Specifies whether the hardware is currently operating outside of its recommended temperature range. The hardware shuts down if the temperature exceeds critical thresholds. |
failure
Indicates the failure code and message.
Name | Type | Description |
---|---|---|
code |
integer |
Message code |
message |
string |
Detailed message based on the state. |
giveback
Represents the state of the node that is giving storage back to its HA partner.
Name | Type | Description |
---|---|---|
failure |
Indicates the failure code and message. |
|
state |
string |
partners
Name | Type | Description |
---|---|---|
_links |
||
name |
string |
|
uuid |
string |
ports
Name | Type | Description |
---|---|---|
number |
unsigned |
HA port number |
state |
string |
HA port state:
|
takeover
This represents the state of the node that is taking over storage from its HA partner.
Name | Type | Description |
---|---|---|
failure |
Indicates the failure code and message. |
|
state |
string |
ha
Name | Type | Description |
---|---|---|
auto_giveback |
boolean |
Specifies whether giveback is automatically initiated when the node that owns the storage is ready. |
enabled |
boolean |
Specifies whether or not storage failover is enabled. |
giveback |
Represents the state of the node that is giving storage back to its HA partner. |
|
partners |
array[partners] |
Nodes in this node's High Availability (HA) group. |
ports |
array[ports] |
|
takeover |
This represents the state of the node that is taking over storage from its HA partner. |
management_interface
The management interface of the node to be added. The subnet mask is set based on the management interface of the cluster or the managment interfaces of other nodes.
Name | Type | Description |
---|---|---|
ip |
The IP configuration for cluster setup. |
management_interfaces
Network interface
Name | Type | Description |
---|---|---|
_links |
||
ip |
IP information |
|
name |
string |
The name of the interface. |
uuid |
string |
The UUID that uniquely identifies the interface. |
ipv4_interface
Object to setup an interface along with its default router.
Name | Type | Description |
---|---|---|
address |
string |
IPv4 or IPv6 address |
gateway |
string |
The IPv4 or IPv6 address of the default router. |
netmask |
string |
Input as netmask length (16) or IPv4 mask (255.255.0.0). For IPv6, you must set the netmask length. The default value is 64. Output is always netmask length. |
ipv6_interface
Object to setup an interface along with its default router.
Name | Type | Description |
---|---|---|
address |
string |
IPv6 address |
gateway |
string |
The IPv6 address of the default router. |
netmask |
integer |
The IPv6 netmask/prefix length. The default value is 64 with a valid range of 1 to 127. |
service_processor
Name | Type | Description |
---|---|---|
dhcp_enabled |
boolean |
Set to "true" to use DHCP to configure an IPv4 interface. |
firmware_version |
string |
The version of firmware installed. |
ipv4_interface |
Object to setup an interface along with its default router. |
|
ipv6_interface |
Object to setup an interface along with its default router. |
|
link_status |
string |
|
mac_address |
string |
|
state |
string |
version
This returns the cluster version information. When the cluster has more than one node, the cluster version is equivalent to the lowest of generation, major, and minor versions on all nodes.
Name | Type | Description |
---|---|---|
full |
string |
The full cluster version string. |
generation |
integer |
The generation portion of the version. |
major |
integer |
The major portion of the version. |
minor |
integer |
The minor portion of the version. |
vm
Name | Type | Description |
---|---|---|
provider_type |
string |
Cloud provider where the VM is hosted. |
error_arguments
Name | Type | Description |
---|---|---|
code |
string |
Argument code |
message |
string |
Message argument |
error
Name | Type | Description |
---|---|---|
arguments |
array[error_arguments] |
Message arguments |
code |
string |
Error code |
message |
string |
Error message |
target |
string |
The target parameter that caused the error. |