Configure HPE VME 8.0.x for FCP and iSCSI with ONTAP storage
The Linux Host Utilities software provides management and diagnostic tools for Linux hosts that are connected to ONTAP storage. When you install the Linux Host Utilities on a HPE VME 8.0.x host, you can use the Host Utilities to help you manage FCP and iSCSI protocol operations with ONTAP LUNs.
Step 1: Install the Linux Host Utilities
NetApp strongly recommends installing the Linux Host Utilities to support ONTAP LUN management and assist technical support with gathering configuration data.
|
|
Installing the Linux Host Utilities doesn't change any host timeout settings on your Linux host. |
Step 2: Confirm the multipath configuration for your host
You can use multipathing with HPE VME 8.0.x to manage ONTAP LUNs.
To ensure that multipathing is configured correctly for your host, verify that the /etc/multipath.conf file is defined and that you have the NetApp recommended settings configured for your ONTAP LUNs.
-
Verify that the
/etc/multipath.conffile exits. If the file doesn't exist, create an empty, zero-byte file:touch /etc/multipath.conf -
The first time the
multipath.conffile is created, you might need to enable and start the multipath services to load the recommended settings:systemctl enable multipathdsystemctl start multipathd -
Each time you boot the host, the empty
/etc/multipath.confzero-byte file automatically loads the NetApp recommended host multipath parameters as the default settings. You shouldn't need to make changes to the/etc/multipath.conffile for your host because the operating system is compiled with the multipath parameters that recognize and manage ONTAP LUNs correctly.The following table shows the Linux OS native compiled multipath parameter settings for ONTAP LUNs.
Show parameter settings
Parameter Setting detect_prio
yes
dev_loss_tmo
"infinity"
failback
immediate
fast_io_fail_tmo
5
features
"2 pg_init_retries 50"
flush_on_last_del
"yes"
hardware_handler
"0"
no_path_retry
queue
path_checker
"tur"
path_grouping_policy
"group_by_prio"
path_selector
"service-time 0"
polling_interval
5
prio
"ontap"
product
LUN
retain_attached_hw_handler
yes
rr_weight
"uniform"
user_friendly_names
no
vendor
NETAPP
-
Verify the parameter settings and path status for your ONTAP LUNs:
multipath -llThe default multipath parameters support ASA, AFF, and FAS configurations. In these configurations, a single ONTAP LUN shouldn't require more than four paths. Having more than four paths can cause problems during a storage failure.
The following example outputs show the correct parameter settings and path status for ONTAP LUNs in an ASA, AFF, or FAS configuration.
ASA configurationAn ASA configuration optimizes all paths to a given LUN, keeping them active. This improves performance by serving I/O operations through all paths at the same time.
Show example
# multipath -ll 3600a098038314c4a433f577471797958 dm-2 NETAPP,LUN C-Mode size=180G features='3 queue_if_no_path pg_init_retries 50' hwhandler='1 alua' wp=rw `-+- policy='service-time 0' prio=50 status=active |- 14:0:0:0 sdc 8:32 active ready running |- 17:0:0:0 sdas 66:192 active ready running |- 14:0:3:0 sdar 66:176 active ready running `- 17:0:3:0 sdch 69:80 active ready running
AFF or FAS configurationAn AFF or FAS configuration should have two groups of paths with higher and lower priorities. Higher priority Active/Optimized paths are served by the controller where the aggregate is located. Lower priority paths are active but non-optimized because they are served by a different controller. Non-optimized paths are only used when optimized paths aren’t available.
The following example displays the output for an ONTAP LUN with two Active/Optimized paths and two Active/Non-Optimized paths:
Show example
# multipath -ll 3600a0980383149764b5d567257516273 dm-0 NETAPP,LUN C-Mode size=150G features='3 queue_if_no_path pg_init_retries 50' hwhandler='1 alua' wp=rw |-+- policy='service-time 0' prio=50 status=active | |- 16:0:3:0 sdcg 69:64 active ready running | `- 10:0:0:0 sdb 8:16 active ready running `-+- policy='service-time 0' prio=10 status=enabled |- 10:0:1:0 sdc 8:32 active ready running `- 16:0:2:0 sdcf 69:48 active ready running
Step 3: Confirm the iSCSI configuration for your host
Ensure that iSCSI is configured correctly for your host.
You perform the following steps on the iSCSI host.
-
Verify that the iSCSI initiator package (open-iscsi) is installed:
$apt list |grep open-iscsiYou should see an output similar to the following example:
open-iscsi/noble-updates,noble-updates,now 2.1.9-3ubuntu5.4 amd64
-
Verify the iSCSI initiator node name, which is located in the
/etc/iscsi/initiatorname.iscsifile:InitiatorName=iqn.YYYY-MM.com.<vendor>:<host_name> -
Configure the iSCSI session timeout parameter located in the
/etc/iscsi/iscsid.conffile:node.session.timeo.replacement_timeout = 5The iSCSI
replacement_timeoutparameter controls how long the iSCSI layer should wait for a timed-out path or session to reestablish itself before failing any commands on it. You should set the value ofreplacement_timeoutto 5 in the iSCSI configuration file. -
Enable the iSCSI service:
$systemctl enable iscsid -
Start the iSCSI service:
$systemctl start iscsid -
Verify that the iSCSI service is running:
$systemctl status iscsidShow example
●iscsid.service - iSCSI initiator daemon (iscsid) Loaded: loaded (/usr/lib/systemd/system/iscsid.service; enabled; preset: disabled) Active: active (running) since Mon 2026-01-12 12:53:18 IST; 2 days ago TriggeredBy: ● iscsid.socket Docs: man:iscsid(8) Main PID: 1127419 (iscsid) Tasks: 2 (limit: 76557) Memory: 4.3M (peak: 8.8M) CPU: 1.657s CGroup: /system.slice/iscsid.service ├─1127418 /usr/sbin/iscsid └─1127419 /usr/sbin/iscsid -
Discover the iSCSI targets:
$iscsiadm --mode discovery --op update --type sendtargets --portal <target_IP>show example
iscsiadm --mode discovery --op update --type sendtargets --portal 192.168.100.197 192.168.100.197:3260,1046 iqn.1992-08.com.netapp:sn.7cd154a7d35411f0a25ed039eaa95f59:vs.8 192.168.200.199:3260,1049 iqn.1992-08.com.netapp:sn.7cd154a7d35411f0a25ed039eaa95f59:vs.8 192.168.100.199:3260,1048 iqn.1992-08.com.netapp:sn.7cd154a7d35411f0a25ed039eaa95f59:vs.8 192.168.200.197:3260,1047 iqn.1992-08.com.netapp:sn.7cd154a7d35411f0a25ed039eaa95f59:vs.8
-
Log in to the targets:
$iscsiadm --mode node -l all -
Set iSCSI to log in automatically when the host boots:
$iscsiadm --mode node -T <target_name> -p <ip:port> -o update -n node.startup -v automaticYou should see an output similar to the following example:
iscsiadm --mode node -T iqn.1992-08.com.netapp:sn.7cd154a7d35411f0a25ed039eaa95f59:vs.8 -p 192.168.100.197:3260 -o update -n node.startup -v automatic
-
Verify the iSCSI sessions:
$iscsiadm --mode sessionShow example
iscsiadm --mode session tcp: [1] 192.168.200.197:3260,1047 iqn.1992-08.com.netapp:sn.7cd154a7d35411f0a25ed039eaa95f59:vs.8 (non-flash) tcp: [2] 192.168.100.197:3260,1046 iqn.1992-08.com.netapp:sn.7cd154a7d35411f0a25ed039eaa95f59:vs.8 (non-flash) tcp: [3] 192.168.100.199:3260,1048 iqn.1992-08.com.netapp:sn.7cd154a7d35411f0a25ed039eaa95f59:vs.8 (non-flash) tcp: [4] 192.168.200.199:3260,1049 iqn.1992-08.com.netapp:sn.7cd154a7d35411f0a25ed039eaa95f59:vs.8 (non-flash)
Step 4: Optionally, exclude a device from multipathing
If required, you can exclude a device from multipathing by adding the WWID for the unwanted device to the "blacklist" stanza for the multipath.conf file.
-
Determine the WWID:
/lib/udev/scsi_id -gud /dev/sda"sda" is the local SCSI disk that you want to add to the blacklist.
An example WWID is
360030057024d0730239134810c0cb833. -
Add the WWID to the "blacklist" stanza:
blacklist { wwid 360030057024d0730239134810c0cb833 devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*" devnode "^hd[a-z]" devnode "^cciss.*" }
Step 5: Customize multipath parameters for ONTAP LUNs
If your host is connected to LUNs from other vendors and any of the multipath parameter settings are overridden, you need to correct them by adding stanzas later in the multipath.conf file that apply specifically to ONTAP LUNs. If you don't do this, the ONTAP LUNs might not work as expected.
Check your /etc/multipath.conf file, especially in the defaults section, for settings that might be overriding the default settings for multipath parameters.
|
|
You shouldn't override the recommended parameter settings for ONTAP LUNs. These settings are required for optimal performance of your host configuration. Contact NetApp support, your OS vendor, or both for more information. |
The following example shows how to correct an overridden default. In this example, the multipath.conf file defines values for path_checker and no_path_retry that aren't compatible with ONTAP LUNs, and you can't remove these parameters because ONTAP storage arrays are still attached to the host. Instead, you correct the values for path_checker and no_path_retry by adding a device stanza to the multipath.conf file that applies specifically to the ONTAP LUNs.
Show example
defaults {
path_checker readsector0
no_path_retry fail
}
devices {
device {
vendor "NETAPP"
product "LUN"
no_path_retry queue
path_checker tur
}
}
Step 6: Review the known issues
There are no known issues.
What's next?
-
Configure HPE VME data stores on the ONTAP LUNs, then configure the virtual machine. Refer to the vendor HPE documentation for more information.