Prepare to install NX-OS software and RCF
Before you install the NX-OS software and the Reference Configuration File (RCF), follow this procedure.
The examples in this procedure use the following switch and node nomenclature:
-
The names of the two Cisco switches are cs1 and cs2.
-
The node names are node1-01, node1-02, node1-03, and node1-04.
-
The cluster LIF names are:
-
node1-01_clus1 and node1-01_clus2 for node1-01
-
node1-02_clus1 and node1-02_clus2 for node1-02
-
node1-03_clus1 and node1-03_clus2 for node1-03
-
node1-04_clus1 and node1-04_clus2 for node1-04
-
-
The
cluster1::*>
prompt indicates the name of the cluster.
The procedure requires the use of both ONTAP commands and Cisco Nexus 9000 Series Switches commands; ONTAP commands are used unless otherwise indicated.
-
If AutoSupport is enabled on this cluster, suppress automatic case creation by invoking an AutoSupport message:
system node autosupport invoke -node * -type all -message MAINT=x h
where x is the duration of the maintenance window in hours.
The AutoSupport message notifies technical support of this maintenance task so that automatic case creation is suppressed during the maintenance window. -
Change the privilege level to advanced, entering y when prompted to continue:
set -privilege advanced
The advanced prompt (
*>
) appears. -
Check the administrative and operational status of each port.
-
Cluster ports
-
Display how many cluster interconnect interfaces are configured in each node for each switch:
network device-discovery show -protocol cdp
Show example
cluster1::*> network device-discovery show -protocol cdp Node/ Local Discovered Protocol Port Device (LLDP: ChassisID) Interface Platform ----------- ------ ------------------------ ---------------- ---------------- node1-01/cdp e10a cs1(FLMXXXXXXXX) Ethernet1/16/3 N9K-C9332D-GX2B e10b cs2(FDOXXXXXXXX) Ethernet1/16/3 N9K-C9332D-GX2B e11a cs1(FLMXXXXXXXX) Ethernet1/16/4 N9K-C9332D-GX2B e11b cs2(FDOXXXXXXXX) Ethernet1/16/4 N9K-C9332D-GX2B e1a cs1(FLMXXXXXXXX) Ethernet1/16/1 N9K-C9332D-GX2B e1b cs2(FDOXXXXXXXX) Ethernet1/16/1 N9K-C9332D-GX2B . . . e7a cs1(FLMXXXXXXXX) Ethernet1/16/2 N9K-C9332D-GX2B e7b cs2(FDOXXXXXXXX) Ethernet1/16/2 N9K-C9332D-GX2B node1-02/cdp e10a cs1(FLMXXXXXXXX) Ethernet1/16/3 N9K-C9332D-GX2B e10b cs2(FDOXXXXXXXX) Ethernet1/16/3 N9K-C9332D-GX2B e11a cs1(FLMXXXXXXXX) Ethernet1/16/4 N9K-C9332D-GX2B e11b cs2(FDOXXXXXXXX) Ethernet1/16/4 N9K-C9332D-GX2B e1a cs1(FLMXXXXXXXX) Ethernet1/16/1 N9K-C9332D-GX2B e1b cs2(FDOXXXXXXXX) Ethernet1/16/1 N9K-C9332D-GX2B . . . e7a cs1(FLM284504N6) Ethernet1/16/2 N9K-C9332D-GX2B e7b cs1(FDO2846056X) Ethernet1/16/2 N9K-C9332D-GX2B . . .
-
Display the network port attributes:
network port show -ipspace Cluster
Show example
cluster1::*> network port show -ipspace Cluster Node: node1-01 Ignore Speed(Mbps) Health Health Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status --------- ------------ ---------------- ---- ---- ----------- -------- ------ e7a Cluster Cluster up 9000 auto/100000 healthy false e7b Cluster Cluster up 9000 auto/100000 healthy false Node: node1-02 Ignore Speed(Mbps) Health Health Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status --------- ------------ ---------------- ---- ---- ----------- -------- ------ e7a Cluster Cluster up 9000 auto/100000 healthy false e7b Cluster Cluster up 9000 auto/100000 healthy false Node: node1-03 Ignore Speed(Mbps) Health Health Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status --------- ------------ ---------------- ---- ---- ----------- -------- ------ e7a Cluster Cluster up 9000 auto/100000 healthy false e7b Cluster Cluster up 9000 auto/100000 healthy false Node: node1-04 Ignore Speed(Mbps) Health Health Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status --------- ------------ ---------------- ---- ---- ----------- -------- ------ e7a Cluster Cluster up 9000 auto/100000 healthy false e7b Cluster Cluster up 9000 auto/100000 healthy false 8 entries were displayed.
-
Display information about the cluster LIFs:
network interface show -vserver Cluster
Show example
cluster1::*> network interface show -vserver Cluster Logical Status Network Current Current Is Vserver Interface Admin/Oper Address/Mask Node Port Home ----------- ------------- ---------- ------------------ --------- ------- ---- Cluster node1-01_clus1 up/up 169.254.36.44/16 node1-01 e7a true node1-01_clus2 up/up 169.254.7.5/16 node1-01 e7b true node1-02_clus1 up/up 169.254.197.206/16 node1-02 e7a true node1-02_clus2 up/up 169.254.195.186/16 node1-02 e7b true node1-03_clus1 up/up 169.254.192.49/16 node1-03 e7a true node1-03_clus2 up/up 169.254.182.76/16 node1-03 e7b true node1-04_clus1 up/up 169.254.59.49/16 node1-04 e7a true node1-04_clus2 up/up 169.254.62.244/16 node1-04 e7b true 8 entries were displayed.
-
-
HA ports
-
Display information about the HA ports:
ha interconnect status show -node <node-name>
Show example
cluster1::*> ha interconnect status show -node node1-01 (system ha interconnect status show) Node: node1-01 Link 0 Status: up Link 1 Status: up Is Link 0 Active: true Is Link 1 Active: true IC RDMA Connection: up Slot: 0 Debug Firmware: no Interconnect Port 0 : Port Name: e1a-17 MTU: 4096 Link Information: ACTIVE Interconnect Port 1 : Port Name: e1b-18 MTU: 4096 Link Information: ACTIVE cluster1::*> ha interconnect status show -node node1-02 (system ha interconnect status show) Node: node1-02 Link 0 Status: up Link 1 Status: up Is Link 0 Active: true Is Link 1 Active: true IC RDMA Connection: up Slot: 0 Debug Firmware: no Interconnect Port 0 : Port Name: e1a-17 MTU: 4096 Link Information: ACTIVE Interconnect Port 1 : Port Name: e1b-18 MTU: 4096 Link Information: ACTIVE . . .
-
-
Storage ports
-
Display information about the storage ports:
storage port show -port-type ENET
Show example
cluster1::*> storage port show -port-type ENET Speed Node Port Type Mode (Gb/s) State Status ------------------ ---- ----- ------- ------ -------- ----------- node1-01 e10a ENET - 100 enabled online e10b ENET - 100 enabled online e11a ENET - 100 enabled online e11b ENET - 100 enabled online node1-02 e10a ENET - 100 enabled online e10b ENET - 100 enabled online e11a ENET - 100 enabled online e11b ENET - 100 enabled online node1-03 e10a ENET - 100 enabled online e10b ENET - 100 enabled online e11a ENET - 100 enabled online node1-04 e10a ENET - 100 enabled online e10b ENET - 100 enabled online e11a ENET - 100 enabled online e11b ENET - 100 enabled online 16 entries were displayed.
-
-
Storage shelf ports
-
Verify that all the storage shelf ports are up with a healthy status:
storage shelf port show
Show example
cluster1::*> storage shelf port show Shelf ID Module State Internal? ----- -- ------ ------------ --------- 1.1 0 A connected false 1 A connected false 2 A connected false 3 A connected false 4 A connected false 5 A connected false 6 A connected false 7 A connected false 8 B connected false 9 B connected false 10 B connected false 11 B connected false 12 B connected false 13 B connected false 14 B connected false 15 B connected false 16 entries were displayed.
-
Verify the connection status of all the storage shelf ports:
storage shelf port show -fields remote-device,remote-port,connector-state
Show example
cluster1::*> storage shelf port show -fields remote-device,remote-port,connector-state shelf id connector-state remote-port remote-device ----- -- --------------- -------------- ----------------- 1.1 0 connected Ethernet1/17/1 CX9332D-cs1 1.1 1 connected Ethernet1/15/1 CX9364D-cs1 1.1 2 connected Ethernet1/17/2 CX9332D-cs1 1.1 3 connected Ethernet1/15/2 CX9364D-cs1 1.1 4 connected Ethernet1/17/3 CX9332D-cs1 1.1 5 connected Ethernet1/15/3 CX9364D-cs1 1.1 6 connected Ethernet1/17/4 CX9332D-cs1 1.1 7 connected Ethernet1/15/4 CX9364D-cs1 1.1 8 connected Ethernet1/19/1 CX9332D-cs1 1.1 9 connected Ethernet1/17/1 CX9364D-cs1 1.1 10 connected Ethernet1/19/2 CX9332D-cs1 1.1 11 connected Ethernet1/17/2 CX9364D-cs1 1.1 12 connected Ethernet1/19/3 CX9332D-cs1 1.1 13 connected Ethernet1/17/3 CX9364D-cs1 1.1 14 connected Ethernet1/19/4 CX9332D-cs1 1.1 15 connected Ethernet1/17/4 CX9364D-cs1 16 entries were displayed.
-
-
-
Verify the connectivity of the remote cluster interfaces.
-
You can use the
network interface check cluster-connectivity show
command to display the details of an accessibility check for cluster connectivity:network interface check cluster-connectivity show
Show example
cluster1::*> network interface check cluster-connectivity show Source Destination Packet Node Date LIF LIF Loss ------ -------------------------- ---------------- --------------- ----------- node1-01 6/4/2025 03:13:33 -04:00 node1-01_clus2 node1-02_clus1 none 6/4/2025 03:13:34 -04:00 node1-01_clus2 node1-02_clus1 none node1-02 6/4/2025 03:13:33 -04:00 node1-02_clus2 node1-01_clus1 none 6/4/2025 03:13:34 -04:00 node1-02_clus2 node1-01_clus2 none . . .
-
Alternatively, you can use the
cluster ping-cluster -node <node-name>
command to check the connectivity:cluster ping-cluster -node <node-name>
Show example
cluster1::*> cluster ping-cluster -node local Host is node1-04 Getting addresses from network interface table... Cluster node1-01_clus1 169.254.36.44 node1-01 e7a Cluster node1-01_clus2 169.254.7.5 node1-01 e7b Cluster node1-02_clus1 169.254.197.206 node1-02 e7a Cluster node1-02_clus2 169.254.195.186 node1-02 e7b Cluster node1-03_clus1 169.254.192.49 node1-03 e7a Cluster node1-03_clus2 169.254.182.76 node1-03 e7b Cluster node1-04_clus1 169.254.59.49 node1-04 e7a Cluster node1-04_clus2 169.254.62.244 node1-04 e7b Local = 169.254.59.49 169.254.62.244 Remote = 169.254.36.44 169.254.7.5 169.254.197.206 169.254.195.186 169.254.192.49 169.254.182.76 Cluster Vserver Id = 4294967293 Ping status: ............ Basic connectivity succeeds on 12 path(s) Basic connectivity fails on 0 path(s) ................................................ Detected 9000 byte MTU on 12 path(s): Local 169.254.59.49 to Remote 169.254.182.76 Local 169.254.59.49 to Remote 169.254.192.49 Local 169.254.59.49 to Remote 169.254.195.186 Local 169.254.59.49 to Remote 169.254.197.206 Local 169.254.59.49 to Remote 169.254.36.44 Local 169.254.59.49 to Remote 169.254.7.5 Local 169.254.62.244 to Remote 169.254.182.76 Local 169.254.62.244 to Remote 169.254.192.49 Local 169.254.62.244 to Remote 169.254.195.186 Local 169.254.62.244 to Remote 169.254.197.206 Local 169.254.62.244 to Remote 169.254.36.44 Local 169.254.62.244 to Remote 169.254.7.5 Larger than PMTU communication succeeds on 12 path(s) RPC status: 6 paths up, 0 paths down (tcp check) 6 paths up, 0 paths down (udp check)
-
-
Verify that the auto-revert command is enabled on all cluster LIFs:
network interface show -vserver Cluster -fields auto-revert
Show example
cluster1::*> network interface show -vserver Cluster -fields auto-revert Logical Vserver Interface Auto-revert ------- ------------------ ----------- Cluster node1-01_clus1 true Cluster node1-01_clus2 true Cluster node1-02_clus1 true Cluster node1-02_clus2 true Cluster node1-03_clus1 true Cluster node1-03_clus2 true Cluster node1-04_clus1 true Cluster node1-04_clus2 true 8 entries were displayed.
After you've prepared to install the NX-OS software and RCF, you install or upgrade the NX-OS software.