Install or upgrade the NX-OS software
Follow this procedure to install or upgrade the NX-OS software on the Nexus 9332D-GX2B switch.
Review requirements
Verify the following:
-
Complete the procedure in Prepare to install NX-OS and RCF.
-
A current backup of the switch configuration.
-
A fully functioning cluster (no errors in the logs or similar issues).
-
Consult the switch compatibility table for the supported ONTAP and NX-OS versions.
-
Software Upgrade and downgrade guides
Refer to the appropriate software and upgrade guides available on the Cisco website for complete documentation on the Cisco switch upgrade and downgrade procedures.
-
Cisco Nexus 9000 and 3000 Upgrade and ISSU Matrix
Provides information on Disruptive Upgrade/Downgrade for Cisco NX-OS software on Nexus 9000 Series Switches based on your current and target releases.
On the page, select Disruptive Upgrade and select your current release and target release from the dropdown list.
The examples in this procedure use the following switch and node nomenclature:
-
The names of the two Cisco switches are cs1 and cs2.
-
The node names are node1-01, node1-02, node1-03, and node1-04.
-
The cluster LIF names are node1-01_clus1, node1-01_clus2, node1-02_clus1, node1-02_clus2, node1-03_clus1, node1-03_clus2, node1-04_clus1, and node1-04_clus2.
-
The
cluster1::*>
prompt indicates the name of the cluster.
Install the software
The procedure requires the use of both ONTAP commands and Cisco Nexus 9000 Series Switches commands; ONTAP commands are used unless otherwise indicated.
|
|
-
Connect the switch to the management network.
-
Use the ping command to verify connectivity to the server hosting the NX-OS software and the RCF.
Show example
This example verifies that the switch can reach the server at IP address 172.19.2.1:
cs2# ping 172.19.2.1 Pinging 172.19.2.1 with 0 bytes of data: Reply From 172.19.2.1: icmp_seq = 0. time= 5910 usec.
-
Display the cluster ports on each node that are connected to the cluster switches:
network device-discovery show
Show example
cluster1::*> network device-discovery show Node/ Local Discovered Protocol Port Device (LLDP: ChassisID) Interface Platform ----------- ------ ------------------------ ---------------- ---------------- node1-01/cdp e10a cs1(FLMXXXXXXXX) Ethernet1/16/3 N9K-C9332D-GX2B e10b cs2(FDOXXXXXXXX) Ethernet1/16/3 N9K-C9332D-GX2B e11a cs1(FLMXXXXXXXX) Ethernet1/16/4 N9K-C9332D-GX2B e11b cs2(FDOXXXXXXXX) Ethernet1/16/4 N9K-C9332D-GX2B e1a cs1(FLMXXXXXXXX) Ethernet1/16/1 N9K-C9332D-GX2B e1b cs2(FDOXXXXXXXX) Ethernet1/16/1 N9K-C9332D-GX2B . . . e7a cs1(FLMXXXXXXXX) Ethernet1/16/2 N9K-C9332D-GX2B e7b cs2(FDOXXXXXXXX) Ethernet1/16/2 N9K-C9332D-GX2B node1-01/lldp e10a cs1 (c8:60:8f:xx:xx:xx) Ethernet1/16/3 - e10b cs2 (04:e3:87:xx:xx:xx) Ethernet1/16/3 - e11a cs1 (c8:60:8f:xx:xx:xx) Ethernet1/16/4 - e11b cs2 (04:e3:87:xx:xx:xx) Ethernet1/16/4 - e1a cs1 (c8:60:8f:xx:xx:xx) Ethernet1/16/1 - e1b cs2 (04:e3:87:xx:xx:xx) Ethernet1/16/1 - . . . e7a cs1 (c8:60:8f:34:78:d3) Ethernet1/16/2 - e7b cs2 (04:e3:87:19:a2:59) Ethernet1/16/2 - . . .
-
Check the administrative and operational status of each port.
-
Cluster ports
-
Verify that all the cluster ports are up with a healthy status:
network port show -ipspace Cluster
Show example
cluster1::*> network port show -ipspace Cluster Node: node1-01 Ignore Speed(Mbps) Health Health Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status --------- ------------ ---------------- ---- ---- ----------- -------- ------ e7a Cluster Cluster up 9000 auto/100000 healthy false e7b Cluster Cluster up 9000 auto/100000 healthy false Node: node1-02 Ignore Speed(Mbps) Health Health Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status --------- ------------ ---------------- ---- ---- ----------- -------- ------ e7a Cluster Cluster up 9000 auto/100000 healthy false e7b Cluster Cluster up 9000 auto/100000 healthy false Node: node1-03 Ignore Speed(Mbps) Health Health Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status --------- ------------ ---------------- ---- ---- ----------- -------- ------ e7a Cluster Cluster up 9000 auto/10000 healthy false e7b Cluster Cluster up 9000 auto/10000 healthy false Node: node1-04 Ignore Speed(Mbps) Health Health Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status --------- ------------ ---------------- ---- ---- ----------- -------- ------ e7a Cluster Cluster up 9000 auto/10000 healthy false e7b Cluster Cluster up 9000 auto/10000 healthy false
-
Verify that all the cluster interfaces (LIFs) are on the home port:
network interface show -role cluster
Show example
cluster1::*> network interface show -role cluster Logical Status Network Current Current Is Vserver Interface Admin/Oper Address/Mask Node Port Home ----------- --------------- ---------- ------------------ --------- ------- ---- Cluster node1-01_clus1 up/up 169.254.36.44/16 node1-01 e7a true node1-01_clus2 up/up 169.254.7.5/16 node1-01 e7b true node1-02_clus1 up/up 169.254.197.206/16 node1-02 e7a true node1-02_clus2 up/up 169.254.195.186/16 node1-02 e7b true node1-03_clus1 up/up 169.254.192.49/16 node1-03 e7a true node1-03_clus2 up/up 169.254.182.76/16 node1-03 e7b true node1-04_clus1 up/up 169.254.59.49/16 node1-04 e7a true node1-04_clus2 up/up 169.254.62.244/16 node1-04 e7b true 8 entries were displayed.
-
Verify that the cluster displays information for both cluster switches:
system cluster-switch show -is-monitoring-enabled-operational true
Show example
cluster1::*> system cluster-switch show -is-monitoring-enabled-operational true Switch Type Address Model --------------------------- ------------------ ---------------- --------------- cs2(FDOXXXXXXXX) cluster-network 10.228.137.233 N9K-C9332D-GX2B Serial Number: FDOXXXXXXXX Is Monitored: true Reason: None Software Version: Cisco Nexus Operating System (NX-OS) Software, Version 10.4(2) Version Source: CDP/ISDP cs1(FLMXXXXXXXX) cluster-network 10.228.137.253 N9K-C9332D-GX2B Serial Number: FLMXXXXXXXX Is Monitored: true Reason: None Software Version: Cisco Nexus Operating System (NX-OS) Software, Version 10.4(2) Version Source: CDP/ISDP 2 entries were displayed.
-
-
HA ports
-
Verify that all the HA ports are up with a healthy status:
ha interconnect status show -node <node-name>
Show example
cluster1::*> ha interconnect status show -node node1-01 (system ha interconnect status show) Node: node1-01 Link 0 Status: up Link 1 Status: up Is Link 0 Active: true Is Link 1 Active: true IC RDMA Connection: up Slot: 0 Debug Firmware: no Interconnect Port 0 : Port Name: e1a-17 MTU: 4096 Link Information: ACTIVE Interconnect Port 1 : Port Name: e1b-18 MTU: 4096 Link Information: ACTIVE cluster1::*> ha interconnect status show -node node1-02 (system ha interconnect status show) Node: node1-02 Link 0 Status: up Link 1 Status: up Is Link 0 Active: true Is Link 1 Active: true IC RDMA Connection: up Slot: 0 Debug Firmware: no Interconnect Port 0 : Port Name: e1a-17 MTU: 4096 Link Information: ACTIVE Interconnect Port 1 : Port Name: e1b-18 MTU: 4096 Link Information: ACTIVE . . .
-
-
Storage ports
-
Verify that all the storage ports are up with a healthy status:
storage port show -port-type ENET
Show example
cluster1::*> storage port show -port-type ENET Speed Node Port Type Mode (Gb/s) State Status ------------------ ---- ----- ------- ------ -------- ----------- node1-01 e10a ENET - 100 enabled online e10b ENET - 100 enabled online e11a ENET - 100 enabled online e11b ENET - 100 enabled online node1-02 e10a ENET - 100 enabled online e10b ENET - 100 enabled online e11a ENET - 100 enabled online e11b ENET - 100 enabled online node1-03 e10a ENET - 100 enabled online e10b ENET - 100 enabled online e11a ENET - 100 enabled online node1-04 e10a ENET - 100 enabled online e10b ENET - 100 enabled online e11a ENET - 100 enabled online e11b ENET - 100 enabled online 16 entries were displayed.
-
-
Storage shelf ports
-
Verify that all the storage shelf ports are up with a healthy status:
storage shelf port show
Show example
cluster1::*> storage shelf port show Shelf ID Module State Internal? ----- -- ------ ------------ --------- 1.1 0 A connected false 1 A connected false 2 A connected false 3 A connected false 4 A connected false 5 A connected false 6 A connected false 7 A connected false 8 B connected false 9 B connected false 10 B connected false 11 B connected false 12 B connected false 13 B connected false 14 B connected false 15 B connected false 16 entries were displayed.
-
Verify the connection status of all the storage shelf ports:
storage shelf port show -fields remote-device,remote-port,connector-state
Show example
cluster1::*> storage shelf port show -fields remote-device,remote-port,connector-state shelf id connector-state remote-port remote-device ----- -- --------------- -------------- ----------------- 1.1 0 connected Ethernet1/17/1 CX9332D-cs1 1.1 1 connected Ethernet1/15/1 CX9364D-cs1 1.1 2 connected Ethernet1/17/2 CX9332D-cs1 1.1 3 connected Ethernet1/15/2 CX9364D-cs1 1.1 4 connected Ethernet1/17/3 CX9332D-cs1 1.1 5 connected Ethernet1/15/3 CX9364D-cs1 1.1 6 connected Ethernet1/17/4 CX9332D-cs1 1.1 7 connected Ethernet1/15/4 CX9364D-cs1 1.1 8 connected Ethernet1/19/1 CX9332D-cs1 1.1 9 connected Ethernet1/17/1 CX9364D-cs1 1.1 10 connected Ethernet1/19/2 CX9332D-cs1 1.1 11 connected Ethernet1/17/2 CX9364D-cs1 1.1 12 connected Ethernet1/19/3 CX9332D-cs1 1.1 13 connected Ethernet1/17/3 CX9364D-cs1 1.1 14 connected Ethernet1/19/4 CX9332D-cs1 1.1 15 connected Ethernet1/17/4 CX9364D-cs1 16 entries were displayed.
-
-
-
Disable auto-revert on the cluster LIFs. The cluster LIFs fail over to the partner cluster switch and remain there as you perform the upgrade procedure on the targeted switch:
network interface modify -vserver Cluster -lif * -auto-revert false
-
Copy the NX-OS software and EPLD images to the Nexus 9332D-GX2B switch.
Show example
cs2# copy sftp: bootflash: vrf management Enter source filename: /code/nxos.10.4.2.bin Enter hostname for the sftp server: 172.19.2.1 Enter username: root Outbound-ReKey for 172.19.2.1:22 Inbound-ReKey for 172.19.2.1:22 root@172.19.2.1's password: sftp> progress Progress meter enabled sftp> get /code/nxos.10.4.2.bin /bootflash/nxos.10.4.2.bin /code/nxos.10.4.2.bin 100% 1261MB 9.3MB/s 02:15 sftp> exit Copy complete, now saving to disk (please wait)... Copy complete. cs2# copy sftp: bootflash: vrf management Enter source filename: /code/n9000-epld.10.4.2.F.img Enter hostname for the sftp server: 172.19.2.1 Enter username: user1 Outbound-ReKey for 172.19.2.1:22 Inbound-ReKey for 172.19.2.1:22 user1@172.19.2.1's password: sftp> progress Progress meter enabled sftp> get /code/n9000-epld.10.4.2.F.img /bootflash/n9000-epld.10.4.2.F.img /code/n9000-epld.10.4.2.F.img 100% 161MB 9.5MB/s 00:16 sftp> exit Copy complete, now saving to disk (please wait)... Copy complete.
-
Verify the running version of the NX-OS software:
show version
Show example
cs2# show version Cisco Nexus Operating System (NX-OS) Software TAC support: http://www.cisco.com/tac Copyright (C) 2002-2025, Cisco and/or its affiliates. All rights reserved. The copyrights to certain works contained in this software are owned by other third parties and used and distributed under their own licenses, such as open source. This software is provided "as is," and unless otherwise stated, there is no warranty, express or implied, including but not limited to warranties of merchantability and fitness for a particular purpose. Certain components of this software are licensed under the GNU General Public License (GPL) version 2.0 or GNU General Public License (GPL) version 3.0 or the GNU Lesser General Public License (LGPL) Version 2.1 or Lesser General Public License (LGPL) Version 2.0. A copy of each such license is available at http://www.opensource.org/licenses/gpl-2.0.php and http://opensource.org/licenses/gpl-3.0.html and http://www.opensource.org/licenses/lgpl-2.1.php and http://www.gnu.org/licenses/old-licenses/library.txt. Software BIOS: version 01.14 NXOS: version 10.4(1) [Feature Release] Host NXOS: version 10.4(1) BIOS compile time: 11/25/2024 NXOS image file is: bootflash:///nxos64-cs.10.4.1.F.bin NXOS compile time: 11/30/2023 12:00:00 [12/14/2023 05:25:50] NXOS boot mode: LXC Hardware cisco Nexus9000 C9332D-GX2B Chassis Intel(R) Xeon(R) CPU D-1633N @ 2.50GHz with 32802156 kB of memory. Processor Board ID FLMXXXXXXXX Device name: cs2 bootflash: 115802886 kB Kernel uptime is 5 day(s), 2 hour(s), 13 minute(s), 21 second(s) Last reset at 3580 usecs after Thu Jun 5 15:55:08 2025 Reason: Reset Requested by CLI command reload System version: 10.4(1) Service: plugin Core Plugin, Ethernet Plugin Active Package(s): cs2#
-
Install the NX-OS image.
Installing the image file causes it to be loaded every time the switch is rebooted.
Show example
cs2# install all nxos bootflash:nxos.10.4.2.bin Installer will perform compatibility check first. Please wait. Installer is forced disruptive Verifying image bootflash:/nxos.10.4.2.bin for boot variable "nxos". [] 100% -- SUCCESS Verifying image type. [] 100% -- SUCCESS Preparing "nxos" version info using image bootflash:/nxos.10.4.2.bin. [] 100% -- SUCCESS Preparing "bios" version info using image bootflash:/nxos.10.4.2.bin. [] 100% -- SUCCESS Performing module support checks. [] 100% -- SUCCESS Notifying services about system upgrade. [] 100% -- SUCCESS Compatibility check is done: Module Bootable Impact Install-type Reason ------ -------- --------------- ------------ --------- 1 yes Disruptive Reset Default upgrade is not hitless Images will be upgraded according to following table: Module Image Running-Version(pri:alt) New-Version Upg-Required ------- --------- ---------------------------------------- ------------------- ------------ 1 nxos 10.4(1) 10.4(2) Yes 1 bios xx.xx.:xx.xx xxx No Switch will be reloaded for disruptive upgrade. Do you want to continue with the installation (y/n)? [n] y Install is in progress, please wait. Performing runtime checks. [] 100% -- SUCCESS Setting boot variables. [] 100% -- SUCCESS Performing configuration copy. [] 100% -- SUCCESS Module 1: Refreshing compact flash and upgrading bios/loader/bootrom. Warning: please do not remove or power off the module at this time. [] 100% -- SUCCESS Finishing the upgrade, switch will reboot in 10 seconds.
-
Verify the new version of NX-OS software after the switch has rebooted:
show version
Show example
cs2# show version Cisco Nexus Operating System (NX-OS) Software TAC support: http://www.cisco.com/tac Copyright (C) 2002-2025, Cisco and/or its affiliates. All rights reserved. The copyrights to certain works contained in this software are owned by other third parties and used and distributed under their own licenses, such as open source. This software is provided "as is," and unless otherwise stated, there is no warranty, express or implied, including but not limited to warranties of merchantability and fitness for a particular purpose. Certain components of this software are licensed under the GNU General Public License (GPL) version 2.0 or GNU General Public License (GPL) version 3.0 or the GNU Lesser General Public License (LGPL) Version 2.1 or Lesser General Public License (LGPL) Version 2.0. A copy of each such license is available at http://www.opensource.org/licenses/gpl-2.0.php and http://opensource.org/licenses/gpl-3.0.html and http://www.opensource.org/licenses/lgpl-2.1.php and http://www.gnu.org/licenses/old-licenses/library.txt. Software BIOS: version 01.14 NXOS: version 10.4(2) [Feature Release] Host NXOS: version 10.4(2) BIOS compile time: 11/25/2024 NXOS image file is: bootflash:///nxos64-cs.10.4.2.F.bin NXOS compile time: 11/30/2023 12:00:00 [12/14/2023 05:25:50] NXOS boot mode: LXC Hardware cisco Nexus9000 C9332D-GX2B Chassis Intel(R) Xeon(R) CPU D-1633N @ 2.50GHz with 32802156 kB of memory. Processor Board ID FLMXXXXXXXX Device name: cs2 bootflash: 115802886 kB Kernel uptime is 5 day(s), 2 hour(s), 13 minute(s), 21 second(s) Last reset at 3580 usecs after Thu Jun 5 15:55:08 2025 Reason: Reset Requested by CLI command reload System version: 10.4(2) Service: plugin Core Plugin, Ethernet Plugin Active Package(s): cs2#
-
Upgrade the EPLD image and reboot the switch.
Show example
cs2# show version module 1 epld EPLD Device Version --------------------------------------- MI FPGA 0x7 IO FPGA 0x17 MI FPGA2 0x2 GEM FPGA 0x2 GEM FPGA 0x2 GEM FPGA 0x2 GEM FPGA 0x2 cs2# install epld bootflash:n9000-epld.10.4.2.F.img module 1 Compatibility check: Module Type Upgradable Impact Reason ------ ------------------ ----------------- --------- ----------- 1 SUP Yes disruptive Module Upgradable Retrieving EPLD versions.... Please wait. Images will be upgraded according to following table: Module Type EPLD Running-Version New-Version Upg-Required ------- ------ ----------------- ----------------- ------------ ------------ 1 SUP MI FPGA 0x07 0x07 No 1 SUP IO FPGA 0x17 0x19 Yes 1 SUP MI FPGA2 0x02 0x02 No The above modules require upgrade. The switch will be reloaded at the end of the upgrade Do you want to continue (y/n) ? [n] y Proceeding to upgrade Modules. Starting Module 1 EPLD Upgrade Module 1 : IO FPGA [Programming] : 100.00% ( 64 of 64 sectors) Module 1 EPLD upgrade is successful. Module Type Upgrade-Result -------- ----- -------------- 1 SUP Success EPLDs upgraded. Module 1 EPLD upgrade is successful.
-
After the switch reboot, log in again and verify that the new version of EPLD loaded successfully.
Show example
cs2# show version module 1 epld EPLD Device Version --------------------------------------- MI FPGA 0x7 IO FPGA 0x19 MI FPGA2 0x2 GEM FPGA 0x2 GEM FPGA 0x2 GEM FPGA 0x2 GEM FPGA 0x2
-
Verify the health of all the ports on the cluster.
-
Cluster ports
-
Verify that cluster ports are up and healthy across all nodes in the cluster:
network port show -ipspace Cluster
Show example
cluster1::*> network port show -ipspace Cluster Node: node1-01 Ignore Speed(Mbps) Health Health Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status --------- ------------ ---------------- ---- ---- ----------- -------- ------ e7a Cluster Cluster up 9000 auto/10000 healthy false e7b Cluster Cluster up 9000 auto/10000 healthy false Node: node1-02 Ignore Speed(Mbps) Health Health Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status --------- ------------ ---------------- ---- ---- ----------- -------- ------ e7a Cluster Cluster up 9000 auto/10000 healthy false e7b Cluster Cluster up 9000 auto/10000 healthy false Node: node1-03 Ignore Speed(Mbps) Health Health Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status --------- ------------ ---------------- ---- ---- ----------- -------- ------ e7a Cluster Cluster up 9000 auto/100000 healthy false e7b Cluster Cluster up 9000 auto/100000 healthy false Node: node1-04 Ignore Speed(Mbps) Health Health Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status --------- ------------ ---------------- ---- ---- ----------- -------- ------ e7a Cluster Cluster up 9000 auto/100000 healthy false e7b Cluster Cluster up 9000 auto/100000 healthy false
-
Verify the switch health from the cluster:
network device-discovery show -protocol cdp
system cluster-switch show -is-monitoring-enabled-operational true
Show example
cluster1::*> network device-discovery show -protocol cdp node1-02/cdp e10a cs1(FLMXXXXXXXX) Ethernet1/16/3 N9K-C9332D-GX2B e10b cs2(FDOXXXXXXXX) Ethernet1/16/3 N9K-C9332D-GX2B e11a cs1(FLMXXXXXXXX) Ethernet1/16/4 N9K-C9332D-GX2B e11b cs2(FDOXXXXXXXX) Ethernet1/16/4 N9K-C9332D-GX2B e1a cs1(FLMXXXXXXXX) Ethernet1/16/1 N9K-C9332D-GX2B e1b cs2(FDOXXXXXXXX) Ethernet1/16/1 N9K-C9332D-GX2B . . . e7a cs1(FLM284504N6) Ethernet1/16/2 N9K-C9332D-GX2B e7b cs2(FDO2846056X) Ethernet1/16/2 N9K-C9332D-GX2B node1-01/cdp e10a cs1(FLMXXXXXXXX) Ethernet1/16/3 N9K-C9332D-GX2B e10b cs2(FDOXXXXXXXX) Ethernet1/16/3 N9K-C9332D-GX2B e11a cs1(FLMXXXXXXXX) Ethernet1/16/4 N9K-C9332D-GX2B e11b cs2(FDOXXXXXXXX) Ethernet1/16/4 N9K-C9332D-GX2B e1a cs1(FLMXXXXXXXX) Ethernet1/16/1 N9K-C9332D-GX2B e1b cs2(FDOXXXXXXXX) Ethernet1/16/1 N9K-C9332D-GX2B . . . e7a cs1(FLMXXXXXXXX) Ethernet1/16/2 N9K-C9332D-GX2B e7b cs2(FDOXXXXXXXX) Ethernet1/16/2 N9K-C9332D-GX2B . . . cluster1::*> system cluster-switch show -is-monitoring-enabled-operational true Switch Type Address Model --------------------------- ------------------ ---------------- --------------- cs2(FDOXXXXXXXX) cluster-network 10.228.137.233 N9K-C9332D-GX2B Serial Number: FDOXXXXXXXX Is Monitored: true Reason: None Software Version: Cisco Nexus Operating System (NX-OS) Software, Version 10.4(2) Version Source: CDP/ISDP cs1(FLMXXXXXXXX) cluster-network 10.228.137.253 N9K-C9332D-GX2B Serial Number: FLMXXXXXXXX Is Monitored: true Reason: None Software Version: Cisco Nexus Operating System (NX-OS) Software, Version 10.4(2) Version Source: CDP/ISDP
-
-
HA ports
-
Verify that all the HA ports are up with a healthy status:
ha interconnect status show -node <node-name>
Show example
cluster1::*> ha interconnect status show -node node1-01 (system ha interconnect status show) Node: node1-01 Link 0 Status: up Link 1 Status: up Is Link 0 Active: true Is Link 1 Active: true IC RDMA Connection: up Slot: 0 Debug Firmware: no Interconnect Port 0 : Port Name: e1a-17 MTU: 4096 Link Information: ACTIVE Interconnect Port 1 : Port Name: e1b-18 MTU: 4096 Link Information: ACTIVE cluster1::*> ha interconnect status show -node node1-02 (system ha interconnect status show) Node: node1-02 Link 0 Status: up Link 1 Status: up Is Link 0 Active: true Is Link 1 Active: true IC RDMA Connection: up Slot: 0 Debug Firmware: no Interconnect Port 0 : Port Name: e1a-17 MTU: 4096 Link Information: ACTIVE Interconnect Port 1 : Port Name: e1b-18 MTU: 4096 Link Information: ACTIVE . . .
-
-
Storage ports
-
Verify that all the storage ports are up with a healthy status:
storage port show -port-type ENET
Show example
cluster1::*> storage port show -port-type ENET Speed Node Port Type Mode (Gb/s) State Status ------------------ ---- ----- ------- ------ -------- ----------- node1-01 e10a ENET - 100 enabled online e10b ENET - 100 enabled online e11a ENET - 100 enabled online e11b ENET - 100 enabled online node1-02 e10a ENET - 100 enabled online e10b ENET - 100 enabled online e11a ENET - 100 enabled online e11b ENET - 100 enabled online node1-03 e10a ENET - 100 enabled online e10b ENET - 100 enabled online e11a ENET - 100 enabled online node1-04 e10a ENET - 100 enabled online e10b ENET - 100 enabled online e11a ENET - 100 enabled online e11b ENET - 100 enabled online 16 entries were displayed.
-
-
Storage shelf ports
-
Verify that all the storage shelf ports are up with a healthy status:
storage shelf port show
Show example
cluster1::*> storage shelf port show Shelf ID Module State Internal? ----- -- ------ ------------ --------- 1.1 0 A connected false 1 A connected false 2 A connected false 3 A connected false 4 A connected false 5 A connected false 6 A connected false 7 A connected false 8 B connected false 9 B connected false 10 B connected false 11 B connected false 12 B connected false 13 B connected false 14 B connected false 15 B connected false 16 entries were displayed.
-
Verify the connection status of all the storage shelf ports:
storage shelf port show -fields remote-device,remote-port,connector-state
Show example
cluster1::*> storage shelf port show -fields remote-device,remote-port,connector-state shelf id connector-state remote-port remote-device ----- -- --------------- -------------- ----------------- 1.1 0 connected Ethernet1/17/1 CX9332D-cs1 1.1 1 connected Ethernet1/15/1 CX9364D-cs1 1.1 2 connected Ethernet1/17/2 CX9332D-cs1 1.1 3 connected Ethernet1/15/2 CX9364D-cs1 1.1 4 connected Ethernet1/17/3 CX9332D-cs1 1.1 5 connected Ethernet1/15/3 CX9364D-cs1 1.1 6 connected Ethernet1/17/4 CX9332D-cs1 1.1 7 connected Ethernet1/15/4 CX9364D-cs1 1.1 8 connected Ethernet1/19/1 CX9332D-cs1 1.1 9 connected Ethernet1/17/1 CX9364D-cs1 1.1 10 connected Ethernet1/19/2 CX9332D-cs1 1.1 11 connected Ethernet1/17/2 CX9364D-cs1 1.1 12 connected Ethernet1/19/3 CX9332D-cs1 1.1 13 connected Ethernet1/17/3 CX9364D-cs1 1.1 14 connected Ethernet1/19/4 CX9332D-cs1 1.1 15 connected Ethernet1/17/4 CX9364D-cs1 16 entries were displayed.
-
-
-
Verify that the cluster is healthy:
cluster show
Show example
cluster1::*> cluster show Node Health Eligibility Epsilon -------------------- ------- ------------ ------------ node1-01 true true false node1-02 true true false node1-03 true true false node1-04 true true true 4 entries were displayed.
-
Repeat steps 6 to 13 to install the NX-OS software and EPLD images on switch cs1.
-
Enable auto-revert on the cluster LIFs.
network interface modify -vserver Cluster -lif * -auto-revert true
-
Verify that the cluster LIFs have reverted to their home port:
network interface show -role cluster
Show example
cluster1::*> network interface show -role cluster Logical Status Network Current Current Is Vserver Interface Admin/Oper Address/Mask Node Port Home ----------- --------------- ---------- ------------------ ----------- ------- ---- Cluster node1-01_clus1 up/up 169.254.36.44/16 node1-01 e7a true node1-01_clus2 up/up 169.254.7.5/16 node1-01 e7b true node1-02_clus1 up/up 169.254.197.206/16 node1-02 e7a true node1-02_clus2 up/up 169.254.195.186/16 node1-02 e7b true node1-03_clus1 up/up 169.254.192.49/16 node1-03 e7a true node1-03_clus2 up/up 169.254.182.76/16 node1-03 e7b true node1-04_clus1 up/up 169.254.59.49/16 node1-04 e7a true node1-04_clus2 up/up 169.254.62.244/16 node1-04 e7b true
If any cluster LIFs have not returned to their home ports, revert them manually from the local node:
network interface revert -vserver Cluster -lif <lif-name>
After you've installed or upgraded the NX-OS software, you install or upgrade the Reference Configuration File (RCF).