Prepare the nodes for upgrade
The controller replacement process begins with a series of prechecks. You also gather information about the original nodes for use later in the procedure and, if required, determine the type of self-encrypting drives that are in use.
-
List the Service Processor (SP) or baseboard management controller (BMC) firmware version running on the old controller:
service-processor show
Verify that you have a supported SP or BMC firmware version:
Old controller SP or BMC Minimum firmware version AFF A800
BMC
10.9
AFF A220
BMC
11.9P1
AFF A200
SP
5.11P1
AFF C190
BMC
11.9P1
FAS2620
SP
5.11P1
FAS2720
BMC
11.9P1
-
Begin the controller replacement process by entering the following command in the advanced privilege mode of the ONTAP command line:
set -privilege advanced
system controller replace start -nodes node_names
You will see output similar to the following example. The output displays the ONTAP version running on your cluster:
Warning: 1. Current ONTAP version is 9.15.1 2. Verify that NVMEM or NVRAM batteries of the new nodes are charged, and charge them if they are not. You need to physically check the new nodes to see if the NVMEM or NVRAM batteries are charged. You can check the battery status either by connecting to a serial console or using SSH, logging into the Service Processor (SP) or Baseboard Management Controller (BMC) for your system, and use the system sensors to see if the battery has a sufficient charge. Attention: Do not try to clear the NVRAM contents. If there is a need to clear the contents of NVRAM, contact NetApp technical support. 3. If a controller was previously part of a different cluster, run wipeconfig before using it as the replacement controller. 4. Note: This is not a MetroCluster configuration. Controller replacement supports only ARL based procedures. Do you want to continue? {y|n}: y
-
Select
y
. You will see the following output:Controller replacement operation: Prechecks in progress. Controller replacement operation has been paused for user intervention.
During the prechecks phase, the system runs the following list of checks in the background.
Precheck Description Cluster Health Check
Checks all the nodes in the cluster to confirm that they are healthy.
Aggregate Relocation Status Check
Checks whether an aggregate relocation is already in progress.
If another aggregate relocation is in progress, the check fails.Model Name Check
Checks whether the controller models are supported for this procedure.
If the models are not supported, the task fails.Cluster Quorum Check
Checks that the nodes being replaced are in quorum. If the nodes are not in quorum, the task fails.
Image Version Check
Checks that the nodes being replaced run the same version of ONTAP.
If the ONTAP image versions are different, the task fails.
The new nodes must have the same version of ONTAP 9.x installed on them that is installed on the original nodes. If the new nodes have a different version of ONTAP installed, you need to netboot the new controllers after you install them. For instructions on how to upgrade ONTAP, refer to References to link to Upgrade ONTAP.HA Status Check
Checks if both the nodes being replaced are in a high availability (HA) pair configuration.
If storage failover is not enabled for the controllers, the task fails.Aggregate Status Check
If the nodes being replaced own aggregates for which they are not the home owner, the task fails.
The nodes should not own any non-local aggregates.Disk Status Check
If any nodes being replaced have missing or failed disks, the task fails.
If any disks are missing, refer to References to link to Disk and aggregate management with the CLI, Logical storage management with the CLI, and HA pair management to configure storage for the HA pair.Data LIF Status Check
Checks if any of the nodes being replaced have non-local data LIFs.
The nodes should not contain any data LIFs for which they are not the home owner. If one of the nodes contains non-local data LIFs, the task fails.Cluster LIF Status
Checks whether the cluster LIFs are up for both nodes. If the cluster LIFs are down, the task fails.
ASUP Status Check
If AutoSupport notifications are not configured, the task fails.
You must enable AutoSupport before beginning the controller replacement procedure.CPU Utilization Check
Checks if the CPU utilization is more than 50% for any of the nodes being replaced.
If the CPU usage is more than 50% for a considerable period of time, the task fails.Aggregate Reconstruction Check
Checks if reconstruction is occurring on any data aggregates.
If aggregate reconstruction is in progress, the task fails.Node Affinity Job Check
Checks if any node affinity jobs are running.
If node affinity jobs are running, the check fails. -
After the controller replacement operation is started and the prechecks are completed, the operation pauses, enabling you to collect output information that you might need later in the controller upgrade process.
-
Run the below set of commands as directed by the controller replacement procedure on the system console.
Run the commands from the serial port connected to each node, run and save the output of the commands individually:
-
vserver services name-service dns show
-
network interface show -curr-node local -role cluster,intercluster,node-mgmt,cluster-mgmt,data
-
network port show -node local -type physical
-
service-processor show -node local -instance
-
network fcp adapter show -node local
-
network port ifgrp show -node local
-
system node show -instance -node local
-
run -node local sysconfig
-
run -node local sysconfig -ac
-
run -node local aggr status -r
-
vol show -fields type
-
run local aggr options data_aggregate_name
-
vol show -fields type , space-guarantee
-
storage aggregate show -node local
-
volume show -node local
-
storage array config show -switch switch_name
-
system license show -owner local
-
storage encryption disk show
-
security key-manager onboard show-backup
-
security key-manager external show
-
security key-manager external show-status
-
network port reachability show -detail -node local
If NetApp Volume Encryption (NVE) or NetApp Aggregate Encryption (NAE) using the Onboard Key Manager is in use, keep the key-manager passphrase ready to complete the key manager resync later in the procedure.
-
-
If your system uses self-encrypting drives, see the Knowledge Base article How to tell if a drive is FIPS certified to determine the type of self-encrypting drives that are in use on the HA pair that you are upgrading. ONTAP software supports two types of self-encrypting drives:
-
FIPS-certified NetApp Storage Encryption (NSE) SAS or NVMe drives
-
Non-FIPS self-encrypting NVMe drives (SED)
You cannot mix FIPS drives with other types of drives on the same node or HA pair.
You can mix SEDs with non-encrypting drives on the same node or HA pair.
-
Correct aggregate ownership if an ARL precheck fails
If the Aggregate Status Check fails, you must return aggregates owned by the partner node to the home owner node and initiate the precheck process again.
-
Return the aggregates currently owned by the partner node to the home owner node:
storage aggregate relocation start -node source_node -destination destination-node -aggregate-list *
-
Verify that neither node1 nor node2 still owns aggregates for which it is the current owner (but not the home owner):
storage aggregate show -nodes node_name -is-home false -fields owner-name, home-name, state
The following example shows the output of the command when a node is both the current owner and home owner of aggregates:
cluster::> storage aggregate show -nodes node1 -is-home true -fields owner-name,home-name,state aggregate home-name owner-name state --------- --------- ---------- ------ aggr1 node1 node1 online aggr2 node1 node1 online aggr3 node1 node1 online aggr4 node1 node1 online 4 entries were displayed.
After you finish
You must restart the controller replacement process:
system controller replace start -nodes node_names
License
Each node in the cluster must have its own NetApp License File (NLF).
If you do not have an NLF, currently licensed features in the cluster are available to the new controller. However, using unlicensed features on the controller might put you out of compliance with your license agreement, so you should install the NLF for the new controller after the upgrade is complete.
Refer to References to link to the NetApp Support Site where you can obtain your NLF. The NLFs are available in the My Support section under Software licenses. If the site does not have the NLFs that you need, contact your NetApp sales representative.
For detailed information about licensing, refer to References to link to the System Administration Reference.