Recable and give back the controller - ASA A70 and ASA A90
Recable the storage and network connections, and then give back the controller.
Step 1: Recable the controller
Recable the controller module's storage and network connections.
-
Recable the the controller module to storage and network conntections.
-
Verify that the cabling is correct by using Active IQ Config Advisor.
-
Download and install Config Advisor.
-
Enter the information for the target system, and then click Collect Data.
-
Click the Cabling tab, and then examine the output. Make sure that all disk shelves are displayed and all disks appear in the output, correcting any cabling issues you find.
-
Check other cabling by clicking the appropriate tab, and then examining the output from Config Advisor.
-
Step 2: Give back the controller
Transfer the ownership of storage resources back to the replacement controller.
-
If your storage system has Encryption configured, you must restore Storage or Volume Encryption functionality using the following procedure to reboot the system:
-
Boot to Menu and run Option 10
-
Input the passphrase & backup up data, then do Normal boot see Restore onboard key management encryption keys.
-
Perform CFO only giveback
-
Perform Onboard Sync and verify SVM-KEK is set to true see Giveback after MB replacement fails - operation was vetoed by keymanager
-
Giveback SFO, (no force)
-
-
If your system does not have Encryption configured, complete the following procedure to reboot the system:
-
Boot to Menu and run Option 1.
-
Give back the controller:
-
From the healthy controller, give back the replaced controller's storage:
storage failover giveback -ofnode replacement_node_name
The replacement controller takes back its storage and completes booting.
If the giveback is vetoed, you can consider overriding the vetoes. -
After the giveback has been completed, confirm that the HA pair is healthy and that takeover is possible:
storage failover show
-
-
Verify that the expected volumes are present for each controller:
vol show -node node-name
-
If you disabled automatic takeover on reboot, enable it from the healthy controller:
storage failover modify -node replacement-node-name -onreboot true