Requirements and considerations - AFF C30 and AFF C60
Before replacing the boot media, make sure to review the following requirements and considerations.
Requirements
-
You must have a USB flash drive, formatted to FAT32, with the appropriate amount of storage to hold the
image_xxx.tgz
. -
You must copy the
image_xxx.tgz
file to the USB flash drive for later use in this procedure. -
You must replace the failed component with a replacement FRU component of the same capacity that you received from your provider.
Considerations
-
It is important that you apply the commands in these steps on the correct controller:
-
The impaired controller is the controller on which you are performing maintenance.
-
The healthy controller is the HA partner of the impaired controller.
-
-
If needed, you can turn on the platform chassis location (blue) LEDs to aid in physically locating the affected platform. Log into the BMC using SSH and enter the
system location-led on
command.A platform chassis has three location LEDs: one on the operator display panel and one on each controller. Location LEDs remain illuminated for 30 minutes.
You can turn them off by entering the
system location-led off
command. If you are unsure if the LEDs are on or off, you can check their state by entering thesystem location-led show
command.